Overview of all channel parameters
ID | Structure | Parameter | Functionality |
|---|---|---|---|
prog_start.slope. | acceleration | Default slope settings | |
vector. | acceleration | Vector dynamic limits | |
gruppe[i]. | achs_anzahl | Group data | |
spindel[i]. | autom_range | Spindle speed range | |
gruppe[i]. | bezeichnung | Group data | |
gruppe[i].achse[j]. | bezeichnung | Axes data | |
spindel[i]. | bezeichnung | Spindle data | |
| cax_face_id | C-axis | |
| corr_v_trans_jerk | J erk at tang. block transition | |
| default_ax_name_of_spindle | C-axis, Tapping | |
gruppe[i].achse[j]. | default_feed_axis | Feed axes group | |
speed_limit_look_ahead. | dist_from_corner | Speed limit Look Ahead | |
speed_limit_look_ahead. | dist_to_corner | Speed limit Look Ahead | |
| einrechnen_mit_t | Tool management | |
| einzelschrittmodus | Single step mode | |
| ext_wzv_vorhanden | External tool management | |
speed_limit_look_ahead. | f_enable | Speed limit Look Ahead | |
speed_limit_look_ahead. | f_time | Speed limit Look Ahead | |
syn_chk. | fehler_gesamt | Syntaxcheck | |
syn_chk. | fehler_pro_zeile | Syntaxcheck | |
| create_cont_mask_warnings | Tool radius compensation | |
aep. | g_gruppe[i] | Reporting of changes | |
| grp_anzahl | Group data | |
aep. | output_mode | Reporting of changes | |
| h_default_output_ax_name[i] | Axis specific H-functions | |
| h_prozess_zeit[i] | Processing time calculation | |
| h_synch[i] | Techno data | |
syn_chk. | interaktiv | Syntaxcheck | |
| kasto_multi_block | Edge banding | |
| kasto_residual_path | Edge banding | |
| kind_of_2nd_ecs_ax | Configuration ECS | |
| kinematik_id | RTCP | |
prog_start. | late_sync_ready | Late Sync at program end | |
| lin_aufloes | Dimension settings | |
gruppe[i].achse[j]. | log_achs_nr | Axes data | |
spindel[i]. | log_achs_nr | Spindle data | |
synchro_data.koppel_gruppe[i]. paar[j]. | log_achs_nr_master | Synchronous operation | |
synchro_data.koppel_gruppe[i]. paar[j]. | log_achs_nr_slave | Synchronous operation | |
| m_default_output_ax_name[i] | Axis specific M-functions | |
| m_prozess_zeit[i] | Processing time calculation | |
| m_synch[i] | Techno data | |
spindel[i]. | m19_prozess_zeit | Processing time calculation | |
spindel[i]. | m19_synch | Techno data | |
spindel[i]. | m3_prozess_zeit | Processing time calculation | |
spindel[i]. | m3_synch | Techno data | |
spindel[i]. | m4_prozess_zeit | Processing time calculation | |
spindel[i]. | m4_synch | Techno data | |
spindel[i]. | m5_prozess_zeit | Processing time calculation | |
spindel[i]. | m5_synch | Techno data | |
| mach_plane_of_2nd_ecs_ax | Configuration ECS | |
| main_spindle_ax_nr | Spindle configuration | |
| main_spindle_gear_change | Spindle gear change | |
| main_spindle_name | Spindle configuration | |
| mass_einh | Dimension settings | |
range_table[j]. | max_speed | Spindle speed range | |
| max_vb_override | Maximum channel override | |
| messtyp | Default measure type | |
range_table[j]. | min_speed | Spindle speed range | |
| mittelpkt_diff | Circle centre point corretion | |
| mittelpkt_faktor | Circle centre point corretion | |
synchro_data.koppel_gruppe[i]. paar[j]. | mode | Synchronous operation | |
makro_def[i]. | nc_code | Symbolic character strings | |
prog_start.g_gruppe[i]. | nr | Default G-functions | |
prog_start.m_gruppe[i]. | nr | Default G-functions | |
| override_delay | Sampling of override | |
| override_weight_prog_feed | Mode of override | |
| p_param_haltend | P-parameter modal | |
aep. | p_parameter | Reporting of changes | |
spindel[i]. | plc_control | Channel specific PLC-spindle | |
| m_pre_outp[i] | Output definition of M code | |
prog_start.slope. | profile | Default slope settings | |
tool. (Old syntax: werkzeug.) | prozess_zeit | Processing time calculation | |
prog_start.slope. | ramp_time | Default slope settings | |
spindel[i]. | range_way | Spindle speed range | |
| reset_no_axis_to_axv | Axis return after reset | |
| tool_life_to_wzv | Tool life data to external tool management | |
| rpf_prozess_zeit | Processing time calculation | |
| rund_aufloes | Dimension settings | |
| rund_mass_einh | Dimension settings | |
spindel[i]. | s_prozess_zeit | Processing time calculation | |
spindel[i]. | s_synch | Techno data | |
| spdl_anzahl | Spindle configuration | |
| spind_aufloes | Dimension settings | |
gruppe[i]. | sub_call | Subcall | |
makro_def[i]. | symbol | Symbolic character strings | |
tool. (Old syntax: werkzeug.) | synch | Techno data | |
| t_info_to_wzv | External tool management | |
aep. | v_eigendef | Reporting of changes | |
speed_limit_look_ahead. | v_limit | Speed limit Look Ahead | |
vector. | velocity | Vector dynamic limits | |
| versch_im_durchm | Turning | |
| wrk_im_kanal_vorhanden | Channel configuration | |
aep. | wz_daten | Reporting of changes | |
kinematik[i]. | param[i] (from V263) | RTCP | |
| log_number_tracking_axis | Axis tracking | |
| feed_to_weakest_axis | Selection of default feed axis | |
| use_drive_curr_limit | Deceleration on feedhold | |
| spindle_m_fct_free | Meaning of M-Functions | |
prog_start. | feedrate | Default feedrate | |
| move_tool_offsets_directly | Effectiveness of tool compensation data | |
| auto_align_tracking_axis | Axis tracking | |
| plc_command_rapid_feed | Mode of PLC command feed | |
| d_clear_to_wzv | External tool management | |
synchro_data. | restore_coupling_after_reset | Synchronous operation | |
synchro_data. | preserve_coupling_after_prog_end | Synchronous operation | |
| t_with_implicit_flush | External tool management | |
| h_pre_outp[i] | Output definition of H-code | |
prog_start. | feedrate_factor | Default unit of feedrate | |
| fast_tracking_transition | Axis tracking | |
| check_jerk_on_poly_path | Consider jerk within polynom | |
| time_override_weight_dwell_time | Time override | |
| ori_rotation_angle | Kinematic transformation | |
| path_reject_std_manual_mode | Manual operation mode | |
| rel_offset_limits_std_manual_mode | Manual operation mode | |
| release_non_channel_axes | Axis return after reset | |
| multi_dimension_in_block | Multiple programming of dimensions in NC block | |
| mode_trans_jerk | Jerk limiting | |
| m6_prog_file | Sub program call with M6 | |
| start_init_prog_file | Sub program call at p rogram start | |
| soft_limit_tolerance | Software limit monitoring | |
| simu_output_wcs | Switching of display data | |
hsc.bspline. | path_deviation | HSC BSpline initialization | |
hsc.bspline. | track_deviation | HSC BSpline initialization | |
hsc.bspline. | max_path_length | HSC BSpline initialization | |
hsc.bspline. | max_angle | HSC BSpline initialization | |
hsc.bspline. | merge_retry | HSC BSpline initialization | |
hsc.bspline. | merge_window | HSC BSpline initialization | |
hsc.bspline. | auto_off_g00 | HSC BSpline initialization | |
hsc.bspline. | auto_off_path | HSC BSpline initialization | |
hsc.bspline. | auto_off_track | HSC BSpline initialization | |
hsc.bspline. | limit_corner_dist | HSC BSpline initialization | |
hsc.gen. | linear_segmentation | HSC general initialization | |
hsc.gen. | linear_center_point | HSC general initialization | |
hsc.gen. | linear_continuous_split | HSC general initialization | |
hsc.gen. | linear_split_length | HSC general initialization | |
hsc.gen. | circular_secant_error | HSC general initialization | |
hsc.gen. | circular_segmentation | HSC general initialization | |
hsc.gen. | circular_param | HSC general initialization | |
hsc.gen. | filter_deviation | HSC general initialization | |
hsc.gen. | min_segment_length | HSC general initialization | |
hsc.gen. | jerk_monitoring_mode | HSC general initialization | |
hsc.gen. | jerk_weighting_5ax | HSC general initialization | |
hsc.gen. | jerk_weighting | HSC general initialization | |
| suppress_cs_tracking_offset | Axis tracking | |
| kin_trafo_display | Display TCP in WO-CS | |
| parameter_change_during_execution | Enabling of list interpretation | |
| soft_limit_warning_axes | Software limit monitoring | |
| multi_axes_in_block | Multiple programming of axes in NC block | |
| kasto_reject_rest_block | Edge banding | |
| remain_block_number_sub_prog_call | Validity of block number | |
P-CHAN-00151 |
| auto_enable_kin_trafo | Trafoanwahl bei Progr.start |
P-CHAN-00152 |
| auto_disable_kin_trafo | Trafoabwahl bei Progr.ende |
| kasto_remain_active | Edge banding, measuring | |
| ax_exchange_with_implicit_flush | Axis exchange with Flush Wait | |
speed_limit_look_ahead. | f_override_weight_v_limit | Speed limit Look Ahead | |
tool. | minimum_length | Tool monitoring | |
tool. | minimum_radius | Tool monitoring | |
| streaming_prog_file | Streaming | |
| modal_i_j_k_for_circle | Modal effect of I/J/K for circles | |
| g80_prog_file | Sub program call for G80 | |
| g81_prog_file | Sub program call for G81 | |
| g82_prog_file | Sub program call for G82 | |
| g83_prog_file | Sub program call for G83 | |
| g84_prog_file | Sub program call for G84 | |
| g85_prog_file | Sub program call for G85 | |
| g86_prog_file | Sub program call for G86 | |
| g87_prog_file | Sub program call for G87 | |
| g88_prog_file | Sub program call for G88 | |
| g89_prog_file | Sub program call for G89 | |
| override_weight_acc | Mode of override | |
| max_radius_diff_circle | Circle radius compensation | |
| max_proz_radius_diff_circle | Circle radius compensation | |
| suppress_ax_group_in_pos_check | Checking exact stop window | |
| channel_name | Channel information | |
| channel_type | Channel information | |
| meas_error_no_signal | Reaction on missing signal for measurement type 1 | |
| mode | HSC Punkt-Vektordarstellung | |
| fixed_axis_index | HSC Punkt-Vektordarstellung | |
| ax_default_config_after_reset | Channel axes after RESET | |
| suppress_prg_display_level | Display data | |
| g00_override_mode | Mode of override | |
|
| plcopen_std_unit | Units in PLCopen commands |
| simu_ignore_internal_stop_cond | Settings for rapid contour visu. | |
|
| kin_trafo_display_curr_pos | Switch display TCP in WO-CS |
| tracking_axis_rot_wc | Axis tracking | |
| override_v_handwheel | Override at manual mode | |
| g800_prog_file[i] | Sub program call for G800 G819 | |
tool_ori_cs. | axis | Automatic orientation | |
| tool_ori_cs. | mode | Automatic orientation |
| dynamic_weighting_active | Path dependend dynamic | |
dynamic_weighting[i]. | path_limit | Path dependend dynamic | |
dynamic_weighting[i]. | velocity_fact | Path dependend dynamic | |
dynamic_weighting[i]. | acceleration_fact | Path dependend dynamic | |
dynamic_weighting[i]. | ramp_time_fact | Path dependend dynamic | |
| man_mode.vector_limit. | v_max_pos | Dynamikdaten kart. Handbetrieb |
| man_mode.vector_limit. | a_max_pos | Dynamikdaten kart. Handbetrieb |
| man_mode.vector_limit. | tr_pos | Dynamikdaten kart. Handbetrieb |
| man_mode.vector_limit. | v_max_ori | Dynamikdaten kart. Handbetrieb |
| man_mode.vector_limit. | a_max_ori | Dynamikdaten kart. Handbetrieb |
| man_mode.vector_limit. | tr_ori | Dynamikdaten kart. Handbetrieb |
hsc.filter. | auto_enable | HSC filter parameter | |
hsc.filter. | order_cart | HSC filter parameter | |
hsc.filter. | order_track | HSC filter parameter | |
| hsc.filter. |
| HSC filter parameter |
| hsc.filter. |
| HSC filter parameter |
| hsc.filter. |
| HSC filter parameter |
| hsc.filter. |
| HSC filter parameter |
vector. | deceleration | Vector dynamic limits | |
| m_h_pre_outp_time_calc_mode | Calculating pre-output time | |
| cycle_changes_modal | Cycle programming | |
| suppress_cycle_logging | Cycle programming | |
| m_h_pre_outp_calc_value_to_go | Calculating residual path/time | |
| gap_in_trafo_axis_sequence | Transformations |