Error reaction for command value based software limit monitoring (P-CHAN-00147)
This parameter defines the error reaction for specific axes of the channel for command value based software limit monitoring. The error reaction of the actual value based monitoring is not affected. The function is a characteristic of the channel axes.
Variable name | Type | Permitted range | Dimension |
soft_limit_warning_axes | UNS32 | 0x0..0xFFFFFFFF | ---- |
0 | Error reaction is feedhold of all axes at command value based exceeding of software limits, channel remains in error state until CNC RESET. (Default) | ||
!=0 | Only output of a warning at command value based exceeding of software limits for the defined axes, machining is continued. |
EXAMPLE:Warning at command value based software limit exceeding for the axes 1 to 3 of the channel.
Extract from channel parameters list:
soft_limit_warning_axes
0x7