Exclusivity of axes programming (P-CHAN-00148)
By the parameter "multi_axes_in_block" the exclusivity of the axes programming can be disabled. This parameter is only evaluated, if also the multiple dimension programming is enabled (P-CHAN-00116).
In this case the multiple axes programming for the same axes in identical dimension (G90/ G91) in the same NC block is allowed.
Programming example
Nxx G90 X10 G91 Y10 Z20 Y1 -> Y relative for 11
Nxx G90 X10 Y10 X2 G91 Z30 -> X absolute on 2
Nxx G90 X10 Y20 G91 Z30 G90 Y5 -> Y absolute on 5Variable name | Type | Permitted range | Dimension |
multi_axes_in_block | BOOLEAN | 0/1 | ---- |
0 | Axes may be programmed only exclusively in the same NC block. (Default). |
1 | Identical axes can be programmed several times in the same NC block. For these axes the same dimension programming (G90/G91) must be used. |