Industrial PC
Fieldbus Components
Drive Technology
Servo drive
AX8000 | Multi-axis servo system
AX2090-ND80 | Mains choke
AX8000 | Multi-axis servo system
AX8xxx | Axis module - Object dictionary
AX86x0 | Power supply module - Object dictionary
AX8xxx | Axis module - Diagnostic messages
Standard-Messages
Diagmessages of module DeviceMain
Diagmessages of module SafeMotion
0001, Primary MC: GLOBAL_Fault with Code 0xXX and Additional Code 0xXX
0002, Primary MC: GLOBAL_Shutdown with Code 0xXX and Additional Code 0xXX
0003, Secondary MC: GLOBAL_Fault with Code 0xXX and Additional Code 0xXX
0004, Secondary MC: GLOBAL_Shutdown with Code 0xXX and Additional Code 0xXX
0005, Primary MC: Stored GLOBAL_Fault with Code 0xXX and Additional Code 0xXX
0006, Secondary MC: Stored GLOBAL_Fault with Code 0xXX and Additional Code 0xXX
0007, Diag-Message-Overflow: II messages got lost
0008, Primary MC: the CRC of the FRAM Data was wrong (Diag-Code=II)
0009, Secondary MC: the CRC of the FRAM Data was wrong (Diag-Code=II)
0010, Reserved CfgData has to be zero st offset II
0011, The password is wrong
0012, The user was not found
0013, The CRC of the login data does not match
0014, The serial number of the login data does not match
0015, The login watchdog has been expired
0016, The user was logged out before
0017, The user has not sufficient access rights
0018, The reserved area of the CfgData was not 0
0019, The CRC of the CfgData was wrong
001A, The user name is wrong at word offset 0xXX when changing the password
001B, The requested number of users is too big
001D, The user update flags are wrong at word offset 0xXX when changing the password
001E, The wrong user (user II) is logged in when changing the password (user II found in the received data)
0021, the maximum Global-Shutdown counter was exceeded in the Vendor Data (maximum value: II, actual value: II)
0080, Safety reports FSoE Group error on channel A
0081, Safety reports FSoE Group error on channel B
0082, Safety reports STO module error on channel A
0083, Safety reports STO module error on channel B
0084, Safety reports FSIN module (digital Inputs) error on channel A
0085, Safety reports FSIN module (digital Inputs) error on channel B
0086, Safety reports Brake module error on channel A
0087, Safety reports Brake module error on channel B
0088, Safety reports Encoder overrange error on channel A
0089, Safety reports Encoder overrange error on channel B
0090, Safety reports Encoder underrange error on channel A
0091, Safety reports Encoder underrange error on channel B
0092, Safety reports Primary Safety Feedback error on channel A
0093, Safety reports Primary Safety Feedback error on channel B
0094, Safety reports Secondary Safety Feedback error on channel A
0095, Safety reports Secondary Safety Feedback error on channel B
0096, Safety reports Encoder voltage statemachine fault on channel A
0097, Safety reports Encoder voltage statemachine fault on channel B
0098, Safety reports Emergency Stop on channel A
0099, Safety reports Emergency Stop on channel B
00AD, Safety reports not defined Drive Command on channel A SS
00AE, Safety reports not defined Drive Command on channel B SS
00B0, Safety Card is in Bootloader mode. Download of valid Firmware is required.
00FF, Internal Error, Additional Errorcode 0xXX
0101, Primary MC: Completed RAM TEST: Starttime: 0xXX and Stoptime: 0xXX . The calculated timediff is 0xXX.
0102, Secondary MC: Completed RAM TEST: Starttime: 0xXX and Stoptime: 0xXX . The calculated timediff is 0xXX.
0103, C1 MCTEST Info: Arg1: 0xXX, Arg2: 0xXX, Arg3: 0xXX.
0104, C2 MCTEST Info: Arg1: 0xXX, Arg2: 0xXX, Arg3: 0xXX.
0115, Controller II: Maximum temperature exceeded. Temperature is 0xXX, should be <= 0xXX.
0116, Controller II: Minimum temperature alert. Temperature is 0xXX, should be >= 0xXX.
0117, Controller II: Temperature difference too high. Difference is II, should be <= II.
0118, Controller II: Maximum voltage alert (Partner_VCC). Voltage is 0xXX, should be <= 0xXX.
0119, Controller II: Minimum voltage alert (Partner_VCC). Voltage is 0xXX, should be >= 0xXX.
011A, Controller II: Maximum voltage alert (ECAT_VCC). Voltage is 0xXX, should be <= 0xXX.
011B, Controller II: Minimum voltage alert (ECAT_VCC). Voltage is 0xXX, should be >= 0xXX.
011E, Controller II: Timer Tick Difference is too high. Difference is 0xXX, should be >= 0xXX.
011F, Controller II: Minimum value alert (Individual ADC Check). Channel parameter = II. Actual value is 0xXX.
0120, Controller II: Maximum value alert (Individual ADC Check). Channel parameter = II. Actual value is 0xXX.
0121, Module Shutdown due to minimum value alert (Individual ADC Check). Channel parameter = II.
1000, The size of the safe User Parameter is too small (II), the expected size is II
1003, The reserved data of the SafeOut User Parameter of module II at byte offset 0xXX has to be 0
1004, The reserved data of the SafeIn User Parameter of module II at byte offset 0xXX has to be 0
100A, The version of the Product-Code (0xXX) is unequal the expected value of 0xXX
100B, The feature bits 0xXX of axis A are not supported, the allowed feature bits are 0xXX
100C, The feature bits 0xXX of axis B are not supported, the allowed feature bits are 0xXX
100F, The version (II (VII.II)) of the safety card is not released, not certified and shall only be used for non-safety-critical tests
1010, The default Project CRC is wrong, the received value is 0xXX
102A, Unallowed Safe User Parameter Version, Received=0xXX Expected=0xXX
102B, The Safe User Parameter Size (II) is unequal to the Safe User Parameter Size for the incremental download (SS)
102C, Unallowed Safe User Parameter Size for the rqeuested features, Received=II Expected=II
102D, Unallowed Safe User Parameter Ident, Received=II Expected=II
102E, Unallowed Safe User Parameter Size, Received=II Expected=II
102F, Unallowed Safe User Parameter Change in RUN, Offset=II Info=0xXX
1030, The size of the safe User Parameter is too big (II), the expected size is II
1515, Wrong SafetyCard Firmware: Number of supported axis does not fit with current device
1516, SafetyCard: Invalid Current scaling shift value for calculation configured. SafetyCard VendorData: II DriveApplication: II
2001, The II. connection has received an invalid FSoE-Cmd in state CONNECTION
2002, The II. connection has received an unknown FSoE-Cmd in state CONNECTION
2003, The II. connection has received an invalid FSoE-ConnID in state CONNECTION
2004, The II. connection has received an invalid FSoE-CRC in state CONNECTION
2005, The FSoE-Watchdog of the II. connection has been expired in state CONNECTION
2006, On the II. connection the received FSoE-Address (0xXX) does not match with the expected FSoE-Address (0xXX)
2007, On the II. connection the received connection data do not match with the sent values
200C, On the II. connection in state CONNECTION the Connection was restarted from the FSoE-Master
200E, A Module fault was detected on the II. connection in state CONNECTION
2011, On the II. connection in state CONNECTION a FSoE-Reset with Error-Code 1 was received which means that the communication partner has received an invalid FSoE-Cmd
2012, On the II. connection in state CONNECTION a FSoE-Reset with Error-Code 2 was received which means that the communication partner has received an unknown FSoE-Cmd
2013, On the II. connection in state CONNECTION a FSoE-Reset with Error-Code 3 was received which means that the communication partner has received an invalid FSoE-ConnID
2014, On the II. connection in state CONNECTION a FSoE-Reset with Error-Code 4 was received which means that the communication partner has received an invalid FSoE-CRC
2015, On the II. connection in state CONNECTION a FSoE-Reset with Error-Code 5 was received which means that the FSoE-Watchdog has been expired in the communication partner
2016, On the II. connection in state CONNECTION a FSoE-Reset with Error-Code 6 was received which means that the communication partner has received an invalid FSoE-Address
2017, On the II. connection in state CONNECTION a FSoE-Reset with Error-Code 7 was received which means that the communication partner has received connection data do not match with the sent values
2018, On the II. connection in state CONNECTION a FSoE-Reset with Error-Code 8 was received which means that the communication partner has received an invalid communication parameter length
2019, On the II. connection in state CONNECTION a FSoE-Reset with Error-Code 9 was received which means that the communication partner has received an invalid FSoE Watchdog
201A, On the II. connection in state CONNECTION a FSoE-Reset with Error-Code 10 was received which means that the communication partner has received an invalid application parameter length
201B, On the II. connection in state CONNECTION a FSoE-Reset with Error-Code 11 was received which means that the communication partner has received invalid application parameter data
201C, On the II. connection in state CONNECTION a FSoE-Reset with Error-Code 12 was received
201D, On the II. connection in state CONNECTION a FSoE-Reset with Error-Code 13 was received
201E, On the II. connection in state CONNECTION a FSoE-Reset with Error-Code 14 was received which means that the communication partner has detected a module fault
201F, On the II. connection in state CONNECTION a FSoE-Reset with Error-Code 0xXX was received
2041, The II. connection has received an invalid FSoE-Cmd in state PARAMETER
2042, The II. connection has received an unknown FSoE-Cmd in state PARAMETER
2043, The II. connection has received an invalid FSoE-ConnID in state PARAMETER
2044, The II. connection has received an invalid FSoE-CRC in state PARAMETER
2045, The FSoE-Watchdog of the II. connection has been expired in state PARAMETER
2047, On the II. connection the received parameter data do not match with the sent values
2048, On the II. connection the received communication parameter length (II) does not match with the expected value of 2
2049, On the II. connection the received FSoE Watchdog (II) is outside the allowed area from 2 to 60000
204A, On the II. connection the received application parameter length (II) is unequal the expected length of II
204B, On the II. connection the received application parameter data are wrong
204C, On the II. connection in state PARAMETER the Connection was restarted from the FSoE-Master
204E, A Module fault was detected on the II. connection in state PARAMETER
2051, On the II. connection in state PARAMETER a FSoE-Reset with Error-Code 1 was received which means that the communication partner has received an invalid FSoE-Cmd
2052, On the II. connection in state PARAMETER a FSoE-Reset with Error-Code 2 was received which means that the communication partner has received an unknown FSoE-Cmd
2053, On the II. connection in state PARAMETER a FSoE-Reset with Error-Code 3 was received which means that the communication partner has received an invalid FSoE-ConnID
2054, On the II. connection in state PARAMETER a FSoE-Reset with Error-Code 4 was received which means that the communication partner has received an invalid FSoE-CRC
2055, On the II. connection in state PARAMETER a FSoE-Reset with Error-Code 5 was received which means that the FSoE-Watchdog has been expired in the communication partner
2056, On the II. connection in state PARAMETER a FSoE-Reset with Error-Code 6 was received which means that the communication partner has received an invalid FSoE-Address
2057, On the II. connection in state PARAMETER a FSoE-Reset with Error-Code 7 was received which means that the communication partner has received connection data do not match with the sent values
2058, On the II. connection in state PARAMETER a FSoE-Reset with Error-Code 8 was received which means that the communication partner has received an invalid communication parameter length
2059, On the II. connection in state PARAMETER a FSoE-Reset with Error-Code 9 was received which means that the communication partner has received an invalid FSoE Watchdog
205A, On the II. connection in state PARAMETER a FSoE-Reset with Error-Code 10 was received which means that the communication partner has received an invalid application parameter length
205B, On the II. connection in state PARAMETER a FSoE-Reset with Error-Code 11 was received which means that the communication partner has received invalid application parameter data
205C, On the II. connection in state PARAMETER a FSoE-Reset with Error-Code 12 was received
205D, On the II. connection in state PARAMETER a FSoE-Reset with Error-Code 13 was received
205E, On the II. connection in state PARAMETER a FSoE-Reset with Error-Code 14 was received which means that the communication partner has detected a module fault
205F, On the II. connection in state PARAMETER a FSoE-Reset with Error-Code 0xXX was received
2061, On the II. connection in state PARAMETER a wrong Command was received, which means that the Safe-Parameter size is wrong (Expected size: II, Received size: II)
2081, The II. connection has received an invalid FSoE-Cmd in state DATA
2082, The II. connection has received an unknown FSoE-Cmd in state DATA
2083, The II. connection has received an invalid FSoE-ConnID in state DATA
2084, The II. connection has received an invalid FSoE-CRC in state DATA
2085, The FSoE-Watchdog of the II. connection has been expired in state DATA
208C, On the II. connection in state DATA the Connection was restarted from the FSoE-Master
208D, The FailSafeData command was received on the II. connection in state DATA
208E, A Module fault was detected on the II. connection in state DATA
2091, On the II. connection in state DATA a FSoE-Reset with Error-Code 1 was received which means that the communication partner has received an invalid FSoE-Cmd
2092, On the II. connection in state DATA a FSoE-Reset with Error-Code 2 was received which means that the communication partner has received an unknown FSoE-Cmd
2093, On the II. connection in state DATA a FSoE-Reset with Error-Code 3 was received which means that the communication partner has received an invalid FSoE-ConnID
2094, On the II. connection in state DATA a FSoE-Reset with Error-Code 4 was received which means that the communication partner has received an invalid FSoE-CRC
2095, On the II. connection in state DATA a FSoE-Reset with Error-Code 5 was received which means that the FSoE-Watchdog has been expired in the communication partner
2096, On the II. connection in state DATA a FSoE-Reset with Error-Code 6 was received which means that the communication partner has received an invalid FSoE-Address
2097, On the II. connection in state DATA a FSoE-Reset with Error-Code 7 was received which means that the communication partner has received connection data do not match with the sent values
2098, On the II. connection in state DATA a FSoE-Reset with Error-Code 8 was received which means that the communication partner has received an invalid communication parameter length
2099, On the II. connection in state DATA a FSoE-Reset with Error-Code 9 was received which means that the communication partner has received an invalid FSoE Watchdog
209A, On the II. connection in state DATA a FSoE-Reset with Error-Code 10 was received which means that the communication partner has received an invalid application parameter length
209B, On the II. connection in state DATA a FSoE-Reset with Error-Code 11 was received which means that the communication partner has received invalid application parameter data
209C, On the II. connection in state DATA a FSoE-Reset with Error-Code 12 was received
209D, On the II. connection in state DATA a FSoE-Reset with Error-Code 13 was received
209E, On the II. connection in state DATA a FSoE-Reset with Error-Code 14 was received which means that the communication partner has detected a module fault
209F, On the II. connection in state DATA a FSoE-Reset with Error-Code 0xXX was received
20C1, The II. connection has received an invalid FSoE-Cmd in state SHUTDOWN
20C2, The II. connection has received an unknown FSoE-Cmd in state SHUTDOWN
20C4, The II. connection has received an invalid FSoE-CRC in state SHUTDOWN
20E3, The II. connection has received the invalid FSoE-ConnID 0 in state SESSION
3100, No groups defined when trying to activate or deactivate groups
3101, The reserved bits are set in value II at offset II when trying to activate or deactivate groups
3102, The operation mode at offset II is not supported when trying to activate or deactivate groups
3103, The deactivation of groups is not enabled for any group so no replacement values should be downloaded
3104, The maximum number (II) of Cfg Data pages was exceeded in the Replacement Values Cfg Data
3105, Invalid FB output size size at offset II of the Replacement Values Cfg Data
3106, Unexpected groupindex in the Replacement values Cfg Data at offset 0xXX
3107, The download of the Activate Project Cfg Data was refused because II bytes of the Replacement Values Cfg Data were missing
3108, To activate the Group II the user has to logged in with access rights Bit 0-15 unequal 0 that the Safe Logic Program will be stopped when logging in
3109, No more definitions of individual replace values for analog FB Outputs in case of Group State unequal RUN are expected at offset II
310A, The offset in the definitions of individual replace values for analog FB Outputs in case of Group State unequal RUN was wrong at offset II
310B, The source process image offset of the Cyclic FRAM Data is outside the FB analog input area at offset II
310C, The source process image offset of the Cyclic FRAM Data has to even at offset II
310D, The size of the Cyclic FRAM Data was exceeding at offset II
310E, The received size of the Cyclic FRAM Data at word offset 24 of the Safe Logic Cfg Data (II) is unequal the calculated value of II
310F, The size of the Cyclic FRAM CfgData in the GroupCfgData was not dividable by 4 at offset II
3110, The offset of the Cyclic FRAM Data in the GroupCfgData was wrong at offset II
3111, The value of II at offset II is not allowed when trying to activate or deactivate groups
3113, FB CAMMON (Word-Offset 0xXX of the CfgData): The TDC2UpperLimit (II) is lower or equal than the maximum position jitter (II)
3114, FB CAMMON (Word-Offset 0xXX of the CfgData): The TDCUpperLimit (II) is lower or equal than the maximum position jitter (II)
3115, FB CAMMON (Word-Offset 0xXX of the CfgData): The value of TDCLowerLimit (plus maximum position jitter) (II) is bigger or equal the configured position of 360� (II)
3116, FB CAMMON (Word-Offset 0xXX of the CfgData): The value of BDCUpperLimit (plus twice the maximum position jitter) (II) is bigger or equal the value of TDCLowerLimit (II)
3117, FB CAMMON (Word-Offset 0xXX of the CfgData): The value of BDCUpperLimit (II) is smaller or equal the configured value of 180� (plus maximum position jitter) (II)
3118, FB CAMMON (Word-Offset 0xXX of the CfgData): The value of BDCLowerLimit (plus maximum position jitter) (II) is greater or equal the configured value of 180� (II)
3119, FB CAMMON (Word-Offset 0xXX of the CfgData): The value of OverrunMax (plus twice the maximum position jitter) (II) is bigger or equal the value of BDCLowerLimit (II)
311A, FB CAMMON (Word-Offset 0xXX of the CfgData): The value of TDCUpperLimit (plus twice the maximum position jitter) (II) is bigger or equal the value of OverrunMax (II)
311B, FB CAMMON (Word-Offset 0xXX of the CfgData): The value of TDC1UpperLimit (plus the maximum position jitter) (II) is bigger or equal the configured position of 360� (II)
311C, FB CAMMON (Word-Offset 0xXX of the CfgData): The value of TDC1LowerLimit (plus twice the maximum position jitter) (II) is bigger or equal the value of TDC1UpperLimit (5d)
311D, FB CAMMON (Word-Offset 0xXX of the CfgData): The value of TDC2LowerLimit (plus twice the maximum position jitter) (II) is bigger or equal the value of BDCLowerLimit (II)
311E, FB CAMMON (Word-Offset 0xXX of the CfgData): The value of TDC2UpperLimit (plus twice the maximum position jitter) (II) is bigger or equal the value of TDC2LowerLimit (II)
311F, The maximum size of the Replacement Values was exceeded at Word-Offset 0xXX of the Group Cfg Data
3120, If no deactivation mode is enabled the offset of the replacement values shall be zero at Word-Offset 0xXX of the Group Cfg Data
3121, No more replacement values expected at byte-offset 0xXX of the Replacement Values Cfg Data
3200, The PROFIsafe-protocol is not supported on this device
3201, The F_ParVersion in the F_Prm_Flag2 of the F-Parameter at Word-Offset 0xXX is unequal 1 (PROFIsafe V2)
3202, The F_CRC1 of the F-Parameter at Word-Offset 0xXX is wrong
3203, The F_CRC_Length in the F_Prm_Flag1 of the F-Parameter is wrong at Word-Offset 0xXX, the expected value is 0 (3 Bytes CRC2)
3206, The I-Parameter CRC in the F-Parameter is wrong at Word-Offset 0xXX
3207, The F_Block_ID in the F_Prm_Flag2 of the F-Parameter is wrong at Word-Offset 0xXX, the expected value is 0 (No F_iPar_CRC, no F_WD_Time 2) or 1 (F_iPar_CRC, no F_WD_Time 2)
3208, The F_Source_Address in the F-Parameter at Word-Offset 0xXX is outside the allowed area of 1-0xFFFE
3209, The F_Destination_Address in the F-Parameter at Word-Offset 0xXX is outside the allowed area of 1-0xFFFE
320A, The F_WD_Time in the F-parameter at Word-Offset 0xXX is outside the allowed range from 2-60000
320B, The F_Destination_Address in the F-Parameter at Word-Offset 0xXX is wrong, the expected value is II
3300, The State OPERATIONAL was left in Restore Mode
3301, Only II CRCs were matching in Restore Mode
3302, The CRC of the Activate Project Cfg Data in Restore Mode does not match, the expected value was 0xXX
3303, No RestoreMode Slaves configured when trying to start the Restore Mode
3304, The CRC of the User List Cfg Data was not matching in Restore Mode, the expected value was 0xXX
3305, The download of the User List Cfg Data is not activated in Restore Mode
3306, The download of the User List Cfg Data in Restore-Mode is not allowed in the state II
3307, The activation of the TwinSAFE Restore Project is not allowed in the state II
3308, The Restore Mode is not supported in EtherCAT state 0xXX
3310, The FSoE-Slave on the II. connection is in Restore-Mode
3311, The FSoE-Master on the II. connection is in Restore-Mode
3400, The II. group has no more errors
3401, The Analog Input at word offset II of the analog input process image has expired maximum allowed deviation to the last stored value, received value: II, last stored value: II
3402, The Wait-Com-Error-Timeout has not been expired when the group II should be deactivated in passivate mode
3403, A module fault happened in group II
3404, The assigned connection reported an error when the group II was deactivated in passivate mode
3405, The connection has been successfully restarted when the group II was deactivated in passivate mode
3410, All groups will enter the ERROR-state because the safe logic program has been restarted
3411, All groups will enter the ERROR-state because the CRC of the Change Group Activation Data was wrong
3412, All groups will enter the ERROR-state because the CRC of the Change FB Parameter Data was wrong
3413, All groups will enter the ERROR-state because the CRC of the Project CRC Data was wrong
3414, All groups will enter the ERROR-state because the CRC of the Power-On Analog Value Check Data was wrong
3415, The TwinSAFE Logic Program was not loaded on C1 because of an inconsistency
3416, The TwinSAFE Logic Program was not loaded on C2 because of an inconsistency
3420, No more EtherCAT size error (EtherCAT Output Size=II, EtherCAT Input Size=II)
3421, The EtherCAT Output Data sizes of the Safety Logic Program (II) and the EtherCAT Configuration (II) are unequal
3422, The EtherCAT Input Data sizes of the Safety Logic Program (II) and the EtherCAT Configuration (II) are unequal
3423, The EtherCAT Output Data sizes for PROFIsafe of the Safety Logic Program (II) and the EtherCAT Configuration (II) are unequal
3424, The EtherCAT Input Data sizes for PROFIsafe of the Safety Logic Program (II) and the EtherCAT Configuration (II) are unequal
3425, The needed EtherCAT Process data buffer size (II) exceeded the maximum available size of II
3501, On the II. connection the changeable FSoE Address of II already exists
3502, On the II. connection the changeable FSoE Address is zero
3800, FB II (ESTOP): An EDM-fault (0xXX) was detected in state SAFE
3802, FB II (ESTOP): An EDM-fault (0xXX) was detected in state RESET
3803, FB II (ESTOP): An EDM-fault (0xXX) was detected in state START
3804, FB II (ESTOP): An DiscTime-Fault (0xXX) was detected in state SAFE, the actual EStopIn-values are 0xXX
3806, FB II (ESTOP): An DiscTime-Fault (0xXX) was detected in state RESET, the actual EStopIn-values are 0xXX
3807, FB II (ESTOP): An DiscTime-Fault (0xXX) was detected in state START, the actual EStopIn-values are 0xXX
3809, FB II (ESTOP): An DiscTime-Fault (0xXX) was detected in state DELAYOUT, the actual EStopIn-values are 0xXX
380F, FB II (ESTOP): At least one activated EDM-Input was not reset in RUN when the EDM Reset time had been expired (Diag-Code=0xXX)
3810, FB II (MON): An EDM-fault (0xXX) was detected in state SAFE
3812, FB II (MON): An EDM-fault (0xXX) was detected in state RESET
3813, FB II (MON): An EDM-fault (0xXX) was detected in state START
3814, FB II (MON): An DiscTime-Fault (0xXX) was detected in state SAFE, the actual MonIn/Secure-values are 0xXX
3816, FB II (MON): An DiscTime-Fault (0xXX) was detected in state RESET, the actual MonIn/Secure-values are 0xXX
3817, FB II (MON): An DiscTime-Fault (0xXX) was detected in state START, the actual MonIn/Secure-values are 0xXX
3818, FB II (MON): An DiscTime-Fault (0xXX) was detected in state RUN, the actual MonIn/Secure-values are 0xXX
3819, FB II (MON): An DiscTime-Fault (0xXX) was detected in state DELAYOUT, the actual MonIn/Secure-values are 0xXX
381A, FB II (MON): An DiscTime-Fault (0xXX) was detected in state FUNCTEST, the actual MonIn/Secure-values are 0xXX
381F, FB II (MON): At least one activated EDM-Input was not reset in RUN when the EDM Reset time had been expired (Diag-Code=0xXX)
3820, FB II (TWOHAND): A Disc-Group-fault (0xXX) was detected in state 1BUTTON, the actual TwoHandIn-values are 0xXX
3821, FB II (TWOHAND): A Disc-Group-fault (0xXX) was detected in state 2BUTTON, the actual TwoHandIn-values are 0xXX
3823, FB II (TWOHAND): An DiscTime-Fault (0xXX) was detected in state SAFE, the actual TwoHandIn-values are 0xXX
3825, FB II (TWOHAND): An DiscTime-Fault (0xXX) was detected in state RESET, the actual TwoHandIn-values are 0xXX
382B, FB II (TWOHAND): An DiscTime-Fault (0xXX) was detected in state 1BUTTON, the actual TwoHandIn-values are 0xXX
382C, FB II (TWOHAND): An DiscTime-Fault (0xXX) was detected in state 2BUTTON, the actual TwoHandIn-values are 0xXX
382D, FB II (TWOHAND): An DiscTime-Fault (0xXX) was detected in state RELEASE, the actual TwoHandIn-values are 0xXX
3830, FB II (OPMODE): An DiscTime-Fault (0xXX) was detected, the actual OpIn-values are 0xXX
3831, FB II (OPMODE): An Input-Fault was detected in state RESET, the actual OpIn-values are 0xXX
3840, FB II (EDM): The SwitchOn-Time had been expired
3841, FB II (EDM): The SwitchOff-Time had been expired
3853, FB II (CS): An DiscTime-Fault (0xXX) was detected in state SAFE, the actual Deactivate-values are 0xXX
3855, FB II (CS): An DiscTime-Fault (0xXX) was detected in state RESET, the actual Deactivate-values are 0xXX
3881, FB II (MUTING): An DiscTime-Fault (0xXX) was detected in state RUN, the actual MuteIn/OssdIn-values are 0xXX
3883, FB II (MUTING): An DiscTime-Fault (0xXX) was detected in state SAFE, the actual MuteIn/OssdIn-values are 0xXX
3885, FB II (MUTING): An DiscTime-Fault (0xXX) was detected in state RESET, the actual MuteIn/OssdIn-values are 0xXX
3888, FB II (MUTING): An DiscTime-Fault (0xXX) was detected in state DELAYOUT, the actual MuteIn/OssdIn-values are 0xXX
3889, FB II (MUTING): An DiscTime-Fault (0xXX) was detected in state MUTING1, the actual MuteIn/OssdIn-values are 0xXX
388A, FB II (MUTING): An DiscTime-Fault (0xXX) was detected in state MUTING2, the actual MuteIn/OssdIn-values are 0xXX
388B, FB II (MUTING): An DiscTime-Fault (0xXX) was detected in state MUTING3, the actual MuteIn/OssdIn-values are 0xXX
388C, FB II (MUTING): An DiscTime-Fault (0xXX) was detected in state MUTING4, the actual MuteIn/OssdIn-values are 0xXX
388D, FB II (MUTING): An DiscTime-Fault (0xXX) was detected in state MUTING5, the actual MuteIn/OssdIn-values are 0xXX
388E, FB II (MUTING): An DiscTime-Fault (0xXX) was detected in state MUTING6, the actual MuteIn/OssdIn-values are 0xXX
388F, FB II (MUTING): An DiscTime-Fault (0xXX) was detected in state MUTING7, the actual MuteIn/OssdIn-values are 0xXX
3890, FB II (MUTING): An DiscTime-Fault (0xXX) was detected in state MUTING8, the actual MuteIn/OssdIn-values are 0xXX
3891, FB II (MUTING): An DiscTime-Fault (0xXX) was detected in state MUTING9, the actual MuteIn/OssdIn-values are 0xXX
3892, FB II (MUTING): State RUN, Sequential Inputs=TRUE: MutingEnable is set and the MuteIn-signals are invalid, the actual MuteIn/OssdIn-values are 0xXX
3893, FB II (MUTING): State RUN, Sequential Inputs=FALSE: MutingEnable is set and the MuteIn-signals are invalid, the actual MuteIn/OssdIn-values are 0xXX
3894, FB II (MUTING): State MUTING1, MutingEnable is set and the OssdIn-signals are invalid, the actual MuteIn/OssdIn-values are 0xXX
3895, FB II (MUTING): State MUTING1, MutingEnable is set and the MuteIn-signals are invalid, the actual MuteIn/OssdIn-values are 0xXX
3896, FB II (MUTING): State MUTING2, MutingEnable is set and the MuteIn-signals before the AOPD are invalid, the actual MuteIn/OssdIn-values are 0xXX
3897, FB II (MUTING): State MUTING2, MutingEnable is set and the MuteIn-signals after the AOPD are invalid, the actual MuteIn/OssdIn-values are 0xXX
3898, FB II (MUTING): State MUTING3, MutingEnable is set and the OssdIn-signals are invalid, the actual MuteIn/OssdIn-values are 0xXX
3899, FB II (MUTING): State MUTING3, Sequential Inputs=TRUE: MutingEnable is set and the MuteIn-signals are invalid, the actual MuteIn/OssdIn-values are 0xXX
389A, FB II (MUTING): State MUTING3, Sequential Inputs=FALSE: MutingEnable is set and the MuteIn-signals are invalid, the actual MuteIn/OssdIn-values are 0xXX
389B, FB II (MUTING): State MUTING4, MutingEnable is set and the OssdIn-signals are invalid, the actual MuteIn/OssdIn-values are 0xXX
389C, FB II (MUTING): State MUTING4, MutingEnable is set and the MuteIn-signals are invalid, the actual MuteIn/OssdIn-values are 0xXX
389D, FB II (MUTING): State MUTING5, MutingEnable is set and the OssdIn-signals are invalid, the actual MuteIn/OssdIn-values are 0xXX
389E, FB II (MUTING): State MUTING5, Sequential Inputs=TRUE: MutingEnable is set and the MuteIn-signals are invalid, the actual MuteIn/OssdIn-values are 0xXX
389F, FB II (MUTING): State MUTING5, Sequential Inputs=FALSE: MutingEnable is set and the MuteIn-signals are invalid, the actual MuteIn/OssdIn-values are 0xXX
38A0, FB II (MUTING): State MUTING6, MutingEnable is set and the OssdIn-signals are invalid, the actual MuteIn/OssdIn-values are 0xXX
38A1, FB II (MUTING): State MUTING6, MutingEnable is set and the MuteIn-signals are invalid, the actual MuteIn/OssdIn-values are 0xXX
38A2, FB II (MUTING): State MUTING7, MutingEnable is set and the MuteIn-signals before the AOPD are invalid, the actual MuteIn/OssdIn-values are 0xXX
38A3, FB II (MUTING): State MUTING7, MutingEnable is set and the MuteIn-signals after the AOPD are invalid, the actual MuteIn/OssdIn-values are 0xXX
38A4, FB II (MUTING): State MUTING8, MutingEnable is set and the OssdIn-signals are invalid, the actual MuteIn/OssdIn-values are 0xXX
38A5, FB II (MUTING): State MUTING8, Sequential Inputs=TRUE, CheckOssdOptional=TRUE: MutingEnable is set and the OssdIn-signals are invalid, the actual MuteIn/OssdIn-values are 0xXX
38A6, FB II (MUTING): State MUTING8, Sequential Inputs=TRUE: MutingEnable is set and the MuteIn-signals are invalid, the actual MuteIn/OssdIn-values are 0xXX
38A7, FB II (MUTING): State MUTING8, Sequential Inputs=FALSE: MutingEnable is set and the MuteIn-signals are invalid, the actual MuteIn/OssdIn-values are 0xXX
38A8, FB II (MUTING): State MUTING9, MutingEnable is set and the OssdIn-signals are invalid, the actual MuteIn/OssdIn-values are 0xXX
38A9, FB II (MUTING): State MUTING9, MutingEnable is set and the MuteIn-signals are invalid, the actual MuteIn/OssdIn-values are 0xXX
38AA, FB II (MUTING): State MUTING5, Sequential Inputs=TRUE, MuteIn3 and MuteIn4 are inactive: MutingEnable is set and the MuteIn-signals are invalid, the actual MuteIn/OssdIn-values are 0xXX
38AB, FB II (MUTING): State MUTING6, Sequential Inputs=TRUE, MuteIn3 and MuteIn4 are inactive: MutingEnable is set and the MuteIn-signals are invalid, the actual MuteIn/OssdIn-values are 0xXX
38AC, FB II (MUTING): State MUTING1, MutingEnable is set and the MuteIn-signals are invalid, the actual MuteIn/OssdIn-values are 0xXX
38B0, FB II (MUTING): At least one activated EDM-Input was not reset in RUN when the EDM Reset time had been expired (Diag-Code=0xXX)
38C1, FB II (MUTING): The Max-Muting-Time had been expired in state MUTING1 (Digital Inputs=0xXX)
38C2, FB II (MUTING): The Max-Muting-Time had been expired in state MUTING2 (Digital Inputs=0xXX)
38C3, FB II (MUTING): The Max-Muting-Time had been expired in state MUTING3 (Digital Inputs=0xXX)
38C4, FB II (MUTING): The Max-Muting-Time had been expired in state MUTING4 (Digital Inputs=0xXX)
38C5, FB II (MUTING): The Max-Muting-Time had been expired in state MUTING5 (Digital Inputs=0xXX)
38C6, FB II (MUTING): The Max-Muting-Time had been expired in state MUTING6 (Digital Inputs=0xXX)
38C7, FB II (MUTING): The Max-Muting-Time had been expired in state MUTING7 (Digital Inputs=0xXX)
38C8, FB II (MUTING): The Max-Muting-Time had been expired in state MUTING8 (Digital Inputs=0xXX)
38C9, FB II (MUTING): The Max-Muting-Time had been expired in state MUTING9 (Digital Inputs=0xXX)
4001, FB II (CAMMON): The TDC2UpperLimit (II) is lower or equal than the maximum position jitter (II)
4002, FB II (CAMMON): The Position (II) is bigger than the maximum position (plus the maximum position jitter) (II)
4003, FB II (CAMMON): The input OverrunCAM was FALSE in the top dead center area, the actual position is II
4004, FB II (CAMMON): The input OverrunCAM changed from FALSE to TRUE outside the area between BDCUpperLimit and TDCLowerLimit, the actual position is II
4005, FB II (CAMMON): The input OverrunCAM was TRUE in the area between OverrunMax and BDCUpperLimit, the actual position is II
4006, FB II (CAMMON): The input OverrunCAM changed from TRUE to FALSE outside the area between OverrunMax and BDCLowerLimit, the actual position is II
4007, FB II (CAMMON): The input UpwardsCAM was FALSE in the area between BDCUpperLimit and TDCLowerLimit, the actual position is II
4008, FB II (CAMMON): The input UpwardsCAM changed from FALSE to TRUE outside the area between BDCLowerLimit and TDCLowerLimit, the actual position is II
4009, FB II (CAMMON): The input UpwardsCAM changed from TRUE to FALSE outside the area between TDCLowerLimit and OverrunMax, the actual position is II
400A, FB II (CAMMON): The Position was moving while waiting for a rising edge of the input Reset in the state MOVE-STOP
400B, FB II (CAMMON): The Position was moving while waiting for a falling edge of the input Reset in the state MOVE-START
400C, FB II (CAMMON): The Position II in the area between OverrunMax and BDCLowerLimit was detected in the state MOVE-UP
400D, FB II (CAMMON): The Position has left the top dead center while waiting for a stop, the actual position is II
400E, FB II (CAMMON): The Position has been changed negative
400F, FB II (CAMMON): The input UpwardsCAM was TRUE in the area between OverrunMax and BDCLowerLimit
4010, FB II (CAMMON): The Position has a circle overflow in Pendulum Mode, actual position=II, last position=II
4011, FB II (CAMMON): The Position has moved while waiting for a rising edge of the input Reset in Pendulum Mode, actual position=II, compare position=II
4012, FB II (CAMMON): The Input BackwardsMove is TRUE while the Position is between 180� and 360�, the actual position is II
4013, FB II (CAMMON): The Input BackwardsMove is TRUE while the moving is clockwise
4014, FB II (CAMMON): The Position has moved while waiting for a falling edge of the input Reset in Pendulum Mode, actual position=II, last position=II
4015, FB II (CAMMON): The value of TDCLowerLimit (plus maximum position jitter) (II) is bigger or equal the configured position of 360� (II)
4016, FB II (CAMMON): The value of BDCUpperLimit (plus twice the maximum position jitter) (II) is bigger or equal the value of TDCLowerLimit (II)
4017, FB II (CAMMON): The value of BDCUpperLimit (II) is smaller or equal the configured value of 180� (plus maximum position jitter) (II)
4018, FB II (CAMMON): The value of BDCLowerLimit (plus maximum position jitter) (II) is greater or equal the configured value of 180� (II)
4019, FB II (CAMMON): The value of OverrunMax (plus twice the maximum position jitter) (II) is bigger or equal the value of BDCLowerLimit (II)
401A, FB II (CAMMON): The value of TDCUpperLimit (plus twice the maximum position jitter) (II) is bigger or equal the value of OverrunMax (II)
401B, FB II (CAMMON): The value of TDC1UpperLimit (plus the maximum position jitter) (II) is bigger or equal the configured position of 360� (II)
401C, FB II (CAMMON): The value of TDC1LowerLimit (plus twice the maximum position jitter) (II) is bigger or equal the value of TDC1UpperLimit (5d)
401D, FB II (CAMMON): The value of TDC2LowerLimit (plus twice the maximum position jitter) (II) is bigger or equal the value of BDCLowerLimit (II)
401E, FB II (CAMMON): The value of TDC2UpperLimit (plus twice the maximum position jitter) (II) is bigger or equal the value of TDC2LowerLimit (II)
401F, FB II (CAMMON): The input PressStarted is TRUE and the position did not move after the PressStartedDelayTime
4020, FB II (CAMMON): The input PressStarted is TRUE and the position has stopped after moving before
4021, FB II (CAMMON): The input PressStarted is TRUE and the position has not moved enough, the actual position is II, the compare position is II
4022, FB II (CAMMON), Pendulum Mode: The Position has changed contra clockwise while moving up clockwise (actual Position=II, old Position=II)
4023, FB II (CAMMON), Pendulum Mode: The Position has changed clockwise while moving up contra clockwise (actual Position=II, old Position=II)
4024, FB II (CAMMON): The Position was moving while waiting for a falling edge of the input Reset in the state WAIT-FOR_RESET
4025, FB II (CAMMON): The TDCUpperLimit (II) is lower or equal than the maximum position jitter (II)
4080, FB II (ADD/SUB): an underflow was detected, AnalogIn1=II, AnalogIn2=II
4081, FB II (ADD/SUB): an overflow was detected, AnalogIn1=II, AnalogIn2=II
4088, FB II (SPEED): an underflow was detected, actual Position=II, old Position=II
4089, FB II (SPEED): an overflow was detected, actual Position=II, old Position=II
4090, FB II (LIMIT): the minimum value (II) is bigger than the maximum value (II)
4098, FB II (COMPARE): an underflow was detected on CompOut (II), the minimum allowed value is II
4099, FB II (COMPARE): an overflow was detected on CompOut (II), the maximum allowed value is II
40A0, FB II (MUL): an underflow was detected, AnalogIn1=II, AnalogIn2=II
40A1, FB II (MUL): an overflow was detected, AnalogIn1=II, AnalogIn2=II
40A8, FB II (DIV): an underflow was detected, AnalogIn1=II, AnalogIn2=II
40A9, FB II (DIV): an overflow was detected, AnalogIn1=II, AnalogIn2=II
40B0, FB II (SCALE): an underflow was detected, AnalogIn=II
40B1, FB II (SCALE): an overflow was detected, AnalogIn=II
40B2, FB II (SCALE): an overflow was detected after multiplication, AnalogIn=II
40B3, FB II (SCALE): an overflow was detected before division when rounding up the value, AnalogIn=II
40B8, FB II (COUNT): an underflow was detected on ActValue (II)
40B9, FB II (COUNT): an overflow was detected on ActValue (II)
40C0, FB II (SLI): an underflow was detected on ActValue (II), the minimum allowed value is II
40C1, FB II (SLI): an overflow was detected on ActValue (II), the maximum allowed value is II
40C8, FB II (ENVELOPE): an underflow was detected on InValue (II), the minimum allowed value is II
40C9, FB II (ENVELOPE): an overflow was detected on InValue (II), the maximum allowed value is II
40CA, FB II (ENVELOPE): an overflow error was detected on InValue (II), InValue+Offset is bigger than the maximum allowed value
40CB, FB II (ENVELOPE): the MaxTime was expired (InValue=II)
40D0, FB II (SLP): MultiturnPos_LL (II) is bigger than MultiturnPos_UL (II)
40D1, FB II (SLP): MultiturnPos_LL=MultiturnPos_UL and SingleturnPos_LL (II) is bigger than SingleturnPos_UL (II)
40D8, FB II (SBT): Brake-Test failed in state II
40D9, FB II (SBT): Brake-Test Interval expired in state II
40DA, FB II (SBT): Brake-Test failed, Actual Position Deviation=II, Maximum Position Deviation=IIInterval expired in state II
6009, SAFEOUT:Initial-Parameter: MultiplierDiagTestPulse has to be greater zero. ModuleNr:0xXX
6010, SAFEOUT:Initial-Parameter: Number of Modules incorrect. ModuleNr:0xXX, Parameter:0xXX
6011, SAFEOUT:Initial-Parameter: Number of Channels incorrect. Parameter0:0xXX, Parameter1:0xXX, Parameter2:0xXX
6012, SAFEOUT:Initial-Parameter: Number of Diagnosis active Module incorrect. Parameter0:0xXX, Parameter1:0xXX, Parameter2:0xXX
6013, SAFEOUT:Initial-Parameter: Number of Diagnosis inactive Module incorrect. Parameter0:0xXX, Parameter1:0xXX, Parameter2:0xXX
6014, SAFEOUT:Initial-Parameter: Number of Feedback active Module incorrect. Parameter0:0xXX, Parameter1:0xXX, Parameter2:0xXX
6015, SAFEOUT:Initial-Parameter: Number of Feedback Diagnosis active Module incorrect. Parameter0:0xXX, Parameter1:0xXX, Parameter2:0xXX
6016, SAFEOUT:Initial-Parameter: Number of Feedback inactive Module incorrect. Parameter0:0xXX, Parameter1:0xXX, Parameter2:0xXX
6017, SAFEOUT:Initial-Parameter: Number of Feedback Diagnosis inactive Module incorrect. Parameter0:0xXX, Parameter1:0xXX, Parameter2:0xXX
6018, SAFEOUT:Initial-Parameter: Number of Diagnosis active Channel incorrect. Parameter0:0xXX, Parameter1:0xXX, Parameter2:0xXX
6019, SAFEOUT:Initial-Parameter: Number of Diagnosis inactive Channel incorrect. Parameter0:0xXX, Parameter1:0xXX, Parameter2:0xXX
601A, SAFEOUT:Initial-Parameter: Number of Feedback active Channel incorrect. Parameter0:0xXX, Parameter1:0xXX, Parameter2:0xXX
601B, SAFEOUT:Initial-Parameter: Number of Feedback Diagnosis active Channel incorrect. Parameter0:0xXX, Parameter1:0xXX, Parameter2:0xXX
601C, SAFEOUT:Initial-Parameter: Number of Feedback inactive Channel incorrect. Parameter0:0xXX, Parameter1:0xXX, Parameter2:0xXX
601D, SAFEOUT:Initial-Parameter: Number of Feedback Diagnosis inactive Channel incorrect. Parameter0:0xXX, Parameter1:0xXX, Parameter2:0xXX
601E, SAFEOUT:Setup Hardware Fault: Module Switch. ReturnData:0xXX, ReturnState:0xXX
601F, SAFEOUT:Setup Hardware Fault: Diagnosis active Module. ReturnData:0xXX, ReturnState:0xXX
6020, SAFEOUT:Setup Hardware Fault: Diagnosis inactive Module. ReturnData:0xXX, ReturnState:0xXX
6021, SAFEOUT:Setup Hardware Fault: Feedback active Module. ReturnData:0xXX, ReturnState:0xXX
6022, SAFEOUT:Setup Hardware Fault: Feedback Diagnosis active Module. ReturnData:0xXX, ReturnState:0xXX
6023, SAFEOUT:Setup Hardware Fault: Feedback inactive Module. ReturnData:0xXX, ReturnState:0xXX
6024, SAFEOUT:Setup Hardware Fault: Feedback Diagnosis inactive Module. ReturnData:0xXX, ReturnState:0xXX
6025, SAFEOUT:Setup Hardware Fault: Channel Switch. ReturnData:0xXX, ReturnState:0xXX
6026, SAFEOUT:Setup Hardware Fault: Diagnosis active Channel. ReturnData:0xXX, ReturnState:0xXX
6027, SAFEOUT:Setup Hardware Fault: Diagnosis inactive Channel. ReturnData:0xXX, ReturnState:0xXX
6028, SAFEOUT:Setup Hardware Fault: Feedback active Channel. ReturnData:0xXX, ReturnState:0xXX
6029, SAFEOUT:Setup Hardware Fault: Feedback Diagnosis active Channel. ReturnData:0xXX, ReturnState:0xXX
602A, SAFEOUT:Setup Hardware Fault: Feedback inactive Channel. ReturnData:0xXX, ReturnState:0xXX
602B, SAFEOUT:Setup Hardware Fault: Feedback Diagnosis inactive Channel. ReturnData:0xXX, ReturnState:0xXX
6030, SAFEOUT:The Feedback of the active Module Switch is wrong. Module:0xXX
6031, SAFEOUT:The Feedback of the inactive Module Switch is wrong. Module:0xXX
6032, SAFEOUT:The Feedback of the active Channel Switch is wrong. Module:0xXX / Channel:0xXX
6033, SAFEOUT:The Feedback of the inactive Channel Switch is wrong. Module:0xXX / Channel:0xXX
6040, SAFEOUT:Diagnosis Test: Common Fault Module:0xXX / DiagChannel:0xXX
6041, SAFEOUT:Diagnosis Test: Unknown State local ModuleState:0xXX
6042, SAFEOUT:Diagnosis Test: Unknown State other ModuleState:0xXX
6050, SAFEOUT:Diagnosis Test: Feedback active Module Switch is wrong (Step1 - check current state). Module:0xXX
6051, SAFEOUT:Diagnosis Test: Feedback inactive Module Switch is wrong (Step1 - check current state). Module:0xXX
6052, SAFEOUT:Diagnosis Test: Feedback active Channel Switch is wrong (Step1 - check current state). Module:0xXX / DiagChannel:0xXX
6053, SAFEOUT:Diagnosis Test: Feedback inactive Channel Switch is wrong (Step1 - check current state). Module:0xXX / DiagChannel:0xXX
6060, SAFEOUT:Diagnosis Test: Feedback active Module Switch is wrong (Step2 - check test pulse). Module:0xXX
6061, SAFEOUT:Diagnosis Test: Feedback inactive Module Switch is wrong (Step2 - check test pulse). Module:0xXX
6062, SAFEOUT:Diagnosis Test: Feedback active Channel Switch is wrong (Step2 - check test pulse). Module:0xXX / DiagChannel:0xXX
6063, SAFEOUT:Diagnosis Test: Feedback inactive Channel Switch is wrong (Step2 - check test pulse). Module:0xXX / DiagChannel:0xXX
6080, SAFEOUT:Diagnosis Test:VendorData. ID: 0xXX Module:0xXX
6081, SAFEOUT:Diagnosis Test:VendorData. ID: 0xXX Module:0xXX
6082, SAFEOUT:Diagnosis Test:VendorData. ID: 0xXX Module:0xXX
6083, SAFEOUT:Diagnosis Test:VendorData. Channel: 0xXX Module:0xXX
6084, SAFEOUT:Diagnosis Test:VendorData. Channel: 0xXX Module:0xXX
6085, SAFEOUT:Diagnosis Test:VendorData. Channel: 0xXX Module:0xXX
6086, SAFEOUT:Diagnosis Test:VendorData. Channel: 0xXX Module:0xXX
6090, SAFEOUT:Module Switch FeedbackTest ViolationCounter incremented, Outputs active. Module:0xXX, Info:0xXX.
6091, SAFEOUT:Module Switch FeedbackTest ViolationCounter incremented, Outputs inactive. Module:0xXX, Info:0xXX.
6092, SAFEOUT:Channel Switch FeedbackTest ViolationCounter incremented, Outputs active. Module:0xXX, Channel:0xXX, Info:0xXX.
6093, SAFEOUT:Channel Switch FeedbackTest ViolationCounter incremented, Outputs inactive. Module:0xXX, Channel:0xXX, Info:0xXX.
6094, SAFEOUT:Module Switch DiagnosisTest ViolationCounter incremented, Outputs active (Step1 - check current state). Module:0xXX, Info:0xXX.
6095, SAFEOUT:Module Switch DiagnosisTest ViolationCounter incremented, Outputs inactive (Step1 - check current state). Module:0xXX, Info:0xXX.
6096, SAFEOUT:Channel Switch DiagnosisTest ViolationCounter incremented, Outputs active (Step1 - check current state). Module:0xXX, Channel:0xXX, Info:0xXX.
6097, SAFEOUT:Channel Switch DiagnosisTest ViolationCounter incremented, Outputs inactive (Step1 - check current state). Module:0xXX, Channel:0xXX, Info:0xXX.
6098, SAFEOUT:Module Switch DiagnosisTest ViolationCounter incremented, Outputs active (Step2 - check test pulse). Module:0xXX, Info:0xXX.
6099, SAFEOUT:Module Switch DiagnosisTest ViolationCounter incremented, Outputs inactive (Step2 - check test pulse). Module:0xXX, Info:0xXX.
609A, SAFEOUT:Channel Switch DiagnosisTest ViolationCounter incremented, Outputs active (Step2 - check test pulse). Module:0xXX, Channel:0xXX, Info:0xXX.
609B, SAFEOUT:Channel Switch DiagnosisTest ViolationCounter incremented, Outputs inactive (Step2 - check test pulse). Module:0xXX, Channel:0xXX, Info:0xXX.
60A0, SAFEOUT:Sercom Fault 0. Cmd/State:0xXX
60A1, SAFEOUT:Sercom Fault 1. Cmd/State:0xXX
60B0, SAFEOUT:Unknown Sercom Command Request 1. Cmd/State:0xXX
60B1, SAFEOUT:Unknown Sercom Command Answer 1. Cmd/State:0xXX
60B2, SAFEOUT:Unknown Sercom Command Request 2. Cmd/State:0xXX
60B3, SAFEOUT:Unknown Sercom Command Answer 2. Cmd/State:0xXX
60C0, SAFEOUT:Module Switch too fast Switching OFF detected Fault (see technical data). Module:0xXX
60C1, SAFEOUT:Channel Switch too fast Switching OFF detected Fault (see technical data). Module:0xXX / Channel:0xXX
60C2, SAFEOUT:Module Switch too fast Switching ON detected Fault (see technical data). Module:0xXX
60C3, SAFEOUT:Channel Switch too fast Switching ON detected Fault (see technical data). Module:0xXX / Channel:0xXX
60C4, SAFEOUT:Module Error Acknowledge is not possible. Module:0xXX
60E0, SAFEOUT:HAL Read Fault. ReturnData:0xXX
60E1, SAFEOUT:Init Fault. Module:0xXX
8009, SAFEIN:Initial-Parameter: MultiplierDiagTestPulse has to be greater zero. ModuleNr:0xXX
8010, SAFEIN:Initial-Parameter: Number of Modules incorrect. ModuleNr:0xXX, Parameter:0xXX
8011, SAFEIN:Initial-Parameter: Number of Channels incorrect. Parameter0:0xXX, Parameter1:0xXX, Parameter2:0xXX
8018, SAFEIN:Initial-Parameter: Number of Diagnosis active Channel incorrect. Parameter0:0xXX, Parameter1:0xXX, Parameter2:0xXX
801B, SAFEIN:Initial-Parameter: Number of Feedback Diagnosis active Channel incorrect. Parameter0:0xXX, Parameter1:0xXX, Parameter2:0xXX
8025, SAFEIN:Setup Hardware Fault: Channel Switch. ReturnData:0xXX, ReturnState:0xXX
8026, SAFEIN:Setup Hardware Fault: Diagnosis active Channel. ReturnData:0xXX, ReturnState:0xXX
8029, SAFEIN:Setup Hardware Fault: Feedback Diagnosis active Channel. ReturnData:0xXX, ReturnState:0xXX
8040, SAFEIN:Diagnosis Test: Common Fault Module:0xXX / DiagChannel:0xXX
8041, SAFEIN:Diagnosis Test: Unknown State local ModuleState:0xXX
8042, SAFEIN:Diagnosis Test: Unknown State Other ModuleState:0xXX
8043, SAFEIN Pulse Detection: Wrong pulse was detected at . Module:0xXX / DiagChannel:0xXX
8044, SAFEIN Pulse Detection: Detected pulse from Module:0xXX / DiagChannel:0xXX
8052, SAFEIN:Diagnosis Test: Feedback in Step1 active Channel is wrong. Module:0xXX / DiagChannel:0xXX
8062, SAFEIN:Diagnosis Test: Feedback in Step2 active Channel is wrong. Module:0xXX / DiagChannel:0xXX
8080, SAFEIN:Diagnosis Test:VendorData. ID: 0xXX Module:0xXX
8081, SAFEIN:Diagnosis Test:VendorData. ID: 0xXX Module:0xXX
8084, SAFEIN:Diagnosis Test:VendorData. Channel: 0xXX Module:0xXX
8085, SAFEIN:Diagnosis Test:VendorData. Channel: 0xXX Module:0xXX
8086, SAFEIN:Diagnosis Test:VendorData. Channel: 0xXX Module:0xXX
8096, SAFEIN:DiagnosisTest ViolationCounter incremented, Inputs active (Step1 - check current state). Module:0xXX, Channel:0xXX, Info:0xXX.
809A, SAFEIN:DiagnosisTest ViolationCounter incremented, Inputs active (Step2 - check test pulse). Module:0xXX, Channel:0xXX, Info:0xXX.
80A0, SAFEIN:Sercom Fault 0. Cmd/State:0xXX
80A1, SAFEIN:Sercom Fault 1. Cmd/State:0xXX
80B0, SAFEIN:Unknown Sercom Command Request 1. Cmd/State:0xXX
80B1, SAFEIN:Unknown Sercom Command Answer 1. Cmd/State:0xXX
80B2, SAFEIN:Unknown Sercom Command Request 2. Cmd/State:0xXX
80B3, SAFEIN:Unknown Sercom Command Answer 2. Cmd/State:0xXX
80C0, SAFEIN:Error Acknowledge is not possible. Module:0xXX
80C1, SAFEIN:Diagnosis Test: Implausible Inputs detected. Module:0xXX
80C2, SAFEIN:Diagnosis Test: Implausible Inputs detected (INFO). Parameter1:0xXX / Parameter2:0xXX
80E0, SAFEIN:Init HAL Fault.ReturnState:0xXX
80E1, SAFEIN:Init Fault. Module:0xXX
80F0, SAFEIN: Testpulse is parametrized but not enabled (Diag Testpulse for Inputs active). Module:0xXX / Channel:0xXX
80F1, SAFEIN: Testpulse is parametrized but not enabled (Diag TestPulse active). Module:0xXX / Channel:0xXX
80F2, SAFEIN: Testfilter-Time too long. Parameter1:0xXX / Parameter2:0xXX
80F3, SAFEIN: Inputfilter-Time too short. Parameter1:0xXX / Parameter2:0xXX
80F4, SAFEIN: Wrong parameters detected for Module:0xXX / Channel:0xXX. Please check parameters!
A081, Transition Pre-Op to Safe-Op not successful. Safetycard not detected.
D000, ENCODER: Module: 0xXX. No Error
D010, ENCODER: Module: 0xXX in State 0xXX. Microcontroller async detected. Info: 0xXX.
D020, ENCODER: Module: 0xXX in State 0xXX. Encoder is in State 'Enabled' and Voltage is too low. Info: 0xXX.
D021, ENCODER: Module: 0xXX in State 0xXX. Encoder is in State 'To Enabled' and Voltage is too low. Info: 0xXX.
D070, ENCODER: Module: 0xXX in State 0xXX. Encoder is in State 'Disabled' and Voltage is too high. Info: 0xXX.
D071, ENCODER: Module: 0xXX in State 0xXX. Encoder is in State 'To Disabled' and Voltage is too high. Info: 0xXX.
D072, ENCODER: Module: 0xXX in State 0xXX. Encoder is in State 'To Enable' and Voltage is too high. Info: 0xXX.
D073, ENCODER: Module: 0xXX in State 0xXX. Encoder is in State 'Enabled' and Voltage is too high. Info: 0xXX.
D180, Primary MC: SAFETY FEEDBACK Module: 0xXX in State 0xXX. No Error
D181, Primary MC: SAFETY FEEDBACK Module: 0xXX in State 0xXX. No new Position received
D182, Primary MC: SAFETY FEEDBACK Module: 0xXX. Invalid Position. Errorcode: 0xXX Info: 0xXX
D183, Primary MC: SAFETY FEEDBACK Module: 0xXX in State 0xXX. DriveApplication reports Feedback Error 0xXX
D184, Primary MC: SAFETY FEEDBACK Module: 0xXX. Safety OCT Feedback not supported by Hardware
D185, Primary MC: SAFETY FEEDBACK Module: 0xXX. EnDat2.2 Feedback not supported by Hardware
D186, Primary MC: SAFETY FEEDBACK Invalid drive application data received. Invalid CRC. Module Id: II Calculated CRC: 0xXX Received CRC: 0xXX
D187, Primary MC: SAFETY FEEDBACK Invalid drive application data received. Invalid Command: 0xXX Module Id: II type: 0xXX
D188, Primary MC: SAFETY FEEDBACK Module: 0xXX. configured Safety User Parameter CRC (0xXX) did not match with Feedback Parameter CRC
D189, Primary MC: SAFETY FEEDBACK Module: 0xXX. Module state sync error. local: 0xXX other: 0xXX
D18A, Primary MC: SAFETY FEEDBACK: FPGA is not validated with this firmware. Elapsed time: II seconds
D18B, Primary MC: SAFETY FEEDBACK Module: 0xXX. Stored Feedback Parameter CRC (0xXX) and Safety User Parameter CRC (0xXX) did not match
D18C, Primary MC: SAFETY FEEDBACK Module: 0xXX. Encoder Safety User Parameter CRC configured but Drive Application (Slot Configuration) not set
D18D, Primary MC: SAFETY FEEDBACK Module: 0xXX. Cannot enable because module is not configured. State: 0xXX DriveAppl: 0xXX
D18E, Primary MC: SAFETY FEEDBACK Module: 0xXX. Double used Parameter CRC (0xXX). Info: 0xXX
D18F, Primary MC: SAFETY FEEDBACK Module: 0xXX. Encoder Voltage not enabled. State: 0xXX
D190, Primary MC: SAFETY FEEDBACK Module: 0xXX. Encoder data buffer overrun. State: 0xXX
D191, Primary MC: SAFETY FEEDBACK Module: 0xXX. Cannot read Encoder info block. Return Code: 0xXX Info: II
D192, Primary MC: SAFETY FEEDBACK Invalid drive application data received. Module Id exceeded: II Expected max: II
D193, Primary MC: SAFETY FEEDBACK Invalid drive application data received. Data length too long: II Expected max: II
D194, Primary MC: SAFETY FEEDBACK Invalid drive application data received. Data length too short: II Expected min: II
D195, Primary MC: SAFETY FEEDBACK Module: 0xXX. Invalid drive application data received. Not allowed in this state: II Command: II
D196, Primary MC: SAFETY FEEDBACK Module: 0xXX. Error during position calculation. Info: 0xXX
D197, Primary MC: SAFETY FEEDBACK Invalid Safety FPGA interface version. Info: 0xXX
D198, Primary MC: SAFETY FEEDBACK Module: 0xXX. Invalid Safedrive Settings Parameter II. value: 0xXX
D199, Primary MC: SAFETY FEEDBACK Module: 0xXX. Not supported by this firmware. CRC: 0xXX
D19A, Primary MC: SAFETY FEEDBACK Module: 0xXX. Safe user parameter position shift value is too large. SingleturnPositionBits: II PositionShiftValue: II
D19B, Primary MC: SAFETY FEEDBACK Module: 0xXX. Motor exchange cannot performed. Stored and current Encoder Parameter mismatch (Subidx: II). Current Encoder Index: II
D19C, Primary MC: SAFETY FEEDBACK Module: 0xXX. Motor exchange cannot performed because other module II is in fault state with errorcode 0xXX
D19D, Primary MC: SAFETY FEEDBACK Module: 0xXX. Motor exchange detected and successfully done.
D19E, Primary MC: SAFETY FEEDBACK Module: 0xXX. SafeUserParameter: EnableForSetReferencingPosition is disabled but reference position is not zero. Ref SingleturnPos: II RefMultiturnPos: II
D19F, Primary MC: SAFETY FEEDBACK Module: 0xXX. SafeUserParameter: MinimumReferencePostion (Singleturn:0xXX Multiturn:II) is larger than MaximumReferencePosition
D1A0, Primary MC: SAFETY FEEDBACK Module: 0xXX. SafeUserParameter: ReferenceSafePosition (Singleturn:0xXX Multiturn:II) is too small. Position exceeded minimum Range
D1A1, Primary MC: SAFETY FEEDBACK SafeUserParameter: Cyclic FRAM data size is not large enough. Allocated size: II Requested size: II
D1A2, Primary MC: SAFETY FEEDBACK Module: 0xXX. SafeUserParameter: Difference between minimal and maximal configured position is too large. Difference: Singleturn:0xXX Multiturn:II
D1A3, Primary MC: SAFETY FEEDBACK Module: 0xXX. Referencing of position in automatic mode is required. No stored position found.
D1A4, Primary MC: SAFETY FEEDBACK Module: 0xXX. Referencing of position cannot be achieved because motor speed is too high. current Speed: II configured limit: II
D1A5, Primary MC: SAFETY FEEDBACK Module: 0xXX. Position deviation on startup is too large. Difference: Singleturn:0xXX Multiturn:II
D1A6, Primary MC: SAFETY FEEDBACK Module: 0xXX. Referenced position exceeded configured minimum range. Current position: Singleturn:0xXX Multiturn:II
D1A7, Primary MC: SAFETY FEEDBACK Module: 0xXX. Referenced position exceeded configured maximum range. Current position: Singleturn:0xXX Multiturn:II
D1A8, Primary MC: SAFETY FEEDBACK Module: 0xXX. SafeUserParameter: ReferenceSafePosition (Singleturn:0xXX Multiturn:II) is too large. Position exceeded maximum Range
D1A9, Primary MC: SAFETY FEEDBACK Module: 0xXX. SafeUserParameter: Referencing Optional Parameter size is invaild. Info: 0xXX. 0xXX.
D1AA, Primary MC: SAFETY FEEDBACK Module: 0xXX. Invalid feedback configuration. Same encoder type on primary and secondary feedback is not permitted. Other Module: II type:II
D1AB, Primary MC: SAFETY FEEDBACK Module: 0xXX. SafeUserParameter: Invalid referencing operation mode selected: II
D1AC, Primary MC: SAFETY FEEDBACK Module: 0xXX. SafeUserParameter: ManualReferencing option and SpeedatReferencePosition is not zero. value: II
D1AD, Primary MC: SAFETY FEEDBACK Module: 0xXX. Position Referencing is not supported because no Multiturn Feedback detected.
D1AE, Primary MC: SAFETY FEEDBACK Module: 0xXX. Shifted Singleturn Position exceeds 32bit. SingleturnPosBits: II PositionShiftBits: II
D1AF, Primary MC: SAFETY FEEDBACK Module: 0xXX. SafeUserParameter: Online change of Referencing mode is not permitted. Current: II New: II
D1B0, Primary MC: SAFETY FEEDBACK Module: 0xXX. Manual Referencing requires download of new Safe User Parameter because position range exceeded.
D280, Secondary MC: SAFETY FEEDBACK Module: 0xXX in State 0xXX. No Error
D281, Secondary MC: SAFETY FEEDBACK Module: 0xXX in State 0xXX. No new Position received
D282, Secondary MC: SAFETY FEEDBACK Module: 0xXX. Invalid Position. Errorcode: 0xXX Info: 0xXX
D283, Secondary MC: SAFETY FEEDBACK Module: 0xXX in State 0xXX. DriveApplication reports Feedback Error 0xXX
D284, Secondary MC: SAFETY FEEDBACK Module: 0xXX. Safety OCT Feedback not supported by Hardware
D285, Secondary MC: SAFETY FEEDBACK Module: 0xXX. EnDat2.2 Feedback not supported by Hardware
D286, Secondary MC: SAFETY FEEDBACK Invalid drive application data received. Invalid Command. Module Id: II type: 0xXX Command: 0xXX
D287, Secondary MC: SAFETY FEEDBACK Invalid drive application data received. Invalid Command: 0xXX Module Id: II type: 0xXX
D288, Secondary MC: SAFETY FEEDBACK Module: 0xXX. configured Safety User Parameter CRC (0xXX) did not match with Feedback Parameter CRC
D289, Secondary MC: SAFETY FEEDBACK Module: 0xXX. Module state sync error. local: 0xXX other: 0xXX
D28A, Secondary MC: SAFETY FEEDBACK: FPGA is not validated with this firmware. Elapsed time: II seconds
D28B, Secondary MC: SAFETY FEEDBACK Module: 0xXX. Stored Feedback Parameter CRC (0xXX) and Safety User Parameter CRC (0xXX) did not match
D28C, Secondary MC: SAFETY FEEDBACK Module: 0xXX. Encoder Safety User Parameter CRC configured but Drive Application (Slot Configuration) not set
D28D, Secondary MC: SAFETY FEEDBACK Module: 0xXX. Cannot enable because module is not configured. State: 0xXX DriveAppl: 0xXX
D28E, Secondary MC: SAFETY FEEDBACK Module: 0xXX. Double used Parameter CRC (0xXX). Info: 0xXX
D28F, Secondary MC: SAFETY FEEDBACK Module: 0xXX. Encoder Voltage not enabled. State: 0xXX
D290, Secondary MC: SAFETY FEEDBACK Module: 0xXX. Encoder data buffer overrun. State: 0xXX
D291, Secondary MC: SAFETY FEEDBACK Module: 0xXX. Cannot read Encoder info block. Return Code: 0xXX Info: II
D292, Secondary MC: SAFETY FEEDBACK Invalid drive application data received. Module Id exceeded: II Expected max: II
D293, Secondary MC: SAFETY FEEDBACK Invalid drive application data received. Data length too long: II Expected max: II
D294, Secondary MC: SAFETY FEEDBACK Invalid drive application data received. Data length too short: II Expected min: II
D295, Secondary MC: SAFETY FEEDBACK Module: 0xXX. Invalid drive application data received. Not allowed in this state: II Command: II
D296, Secondary MC: SAFETY FEEDBACK Module: 0xXX. Error during position calculation. Info: 0xXX
D297, Secondary MC: SAFETY FEEDBACK Invalid Safety FPGA interface version. Info: 0xXX
D298, Secondary MC: SAFETY FEEDBACK Module: 0xXX. Invalid Safedrive Settings Parameter II. value: 0xXX
D299, Secondary MC: SAFETY FEEDBACK Module: 0xXX. Not supported by this firmware. CRC: 0xXX
D29A, Secondary MC: SAFETY FEEDBACK Module: 0xXX. Safe user parameter position shift value is too large. SingleturnPositionBits: II PositionShiftValue: II
D29B, Secondary MC: SAFETY FEEDBACK Module: 0xXX. Motor exchange cannot performed. Stored and current Encoder Parameter mismatch (Subidx: II). Current Encoder Index: II
D29C, Secondary MC: SAFETY FEEDBACK Module: 0xXX. Motor exchange cannot performed because other module II is in fault state with errorcode 0xXX
D29D, Secondary MC: SAFETY FEEDBACK Module: 0xXX. Motor exchange detected and successfully done.
D29E, Secondary MC: SAFETY FEEDBACK Module: 0xXX. SafeUserParameter: EnableForSetReferencingPosition is disabled but reference position is not zero. Ref SingleturnPos: II RefMultiturnPos: II
D29F, Secondary MC: SAFETY FEEDBACK Module: 0xXX. SafeUserParameter: MinimumReferencePostion (Singleturn:0xXX Multiturn:II) is larger than MaximumReferencePosition
D2A0, Secondary MC: SAFETY FEEDBACK Module: 0xXX. SafeUserParameter: ReferenceSafePosition (Singleturn:0xXX Multiturn:II) is too small. Position exceeded minimum Range
D2A1, Secondary MC: SAFETY FEEDBACK SafeUserParameter: Cyclic FRAM data size is not large enough. Allocated size: II Requested size: II
D2A2, Secondary MC: SAFETY FEEDBACK Module: 0xXX. SafeUserParameter: Difference between minimal and maximal configured position is too large. Difference: Singleturn:0xXX Multiturn:II
D2A3, Secondary MC: SAFETY FEEDBACK Module: 0xXX. Referencing of position in automatic mode is required. No stored position found.
D2A4, Secondary MC: SAFETY FEEDBACK Module: 0xXX. Referencing of position cannot be achieved because motor speed is too high. current Speed: II configured limit: II
D2A5, Secondary MC: SAFETY FEEDBACK Module: 0xXX. Position deviation on startup is too large. Difference: Singleturn:0xXX Multiturn:II
D2A6, Secondary MC: SAFETY FEEDBACK Module: 0xXX. Referenced position exceeded configured minimum range. Current position: Singleturn:0xXX Multiturn:II
D2A7, Secondary MC: SAFETY FEEDBACK Module: 0xXX. Referenced position exceeded configured maximum range. Current position: Singleturn:0xXX Multiturn:II
D2A8, Secondary MC: SAFETY FEEDBACK Module: 0xXX. SafeUserParameter: ReferenceSafePosition (Singleturn:0xXX Multiturn:II) is too large. Position exceeded maximum Range
D2A9, Secondary MC: SAFETY FEEDBACK Module: 0xXX. SafeUserParameter: Referencing Optional Parameter size is invaild. Info: 0xXX. 0xXX.
D2AA, Secondary MC: SAFETY FEEDBACK Module: 0xXX. Invalid feedback configuration. Same encoder type on primary and secondary feedback is not permitted. Other Module: II type:II
D2AB, Secondary MC: SAFETY FEEDBACK Module: 0xXX. SafeUserParameter: Invalid referencing operation mode selected: II
D2AC, Secondary MC: SAFETY FEEDBACK Module: 0xXX. SafeUserParameter: ManualReferencing option and SpeedatReferencePosition is not zero. value: II
D2AD, Secondary MC: SAFETY FEEDBACK Module: 0xXX. Position Referencing is not supported because no Multiturn Feedback detected.
D2AE, Secondary MC: SAFETY FEEDBACK Module: 0xXX. Shifted Singleturn Position exceeds 32bit. SingleturnPosBits: II PositionShiftBits: II
D2AF, Secondary MC: SAFETY FEEDBACK Module: 0xXX. SafeUserParameter: Online change of Referencing mode is not permitted. Current: II New: II
D2B0, Secondary MC: SAFETY FEEDBACK Module: 0xXX. Manual Referencing requires download of new Safe User Parameter because position range exceeded.
D300, SafeMotion Axis A Diag Message 1
D301, SafeMotion Axis A Diag Message 2
D302, SafeMotion Axis A Diag Message 3
D303, SafeMotion Axis A Diag Message 4
D304, SafeMotion Axis A Diag Message 5
D305, SafeMotion Axis A Diag Message 6
D306, SafeMotion Axis A Diag Message 7
D307, SafeMotion Axis A Diag Message 8
D308, SafeMotion Axis A Diag Message 9
D309, SafeMotion Axis A Diag Message 10
D30A, SafeMotion Axis A Diag Message 11
D30B, SafeMotion Axis A Diag Message 12
D30C, SafeMotion Axis A Diag Message 13
D30D, SafeMotion Axis A Diag Message 14
D30E, SafeMotion Axis A Diag Message 15
D30F, SafeMotion Axis A Diag Message 16
D310, SafeMotion Axis B Diag Message 1
D311, SafeMotion Axis B Diag Message 2
D312, SafeMotion Axis B Diag Message 3
D313, SafeMotion Axis B Diag Message 4
D314, SafeMotion Axis B Diag Message 5
D315, SafeMotion Axis B Diag Message 6
D316, SafeMotion Axis B Diag Message 7
D317, SafeMotion Axis B Diag Message 8
D318, SafeMotion Axis B Diag Message 9
D319, SafeMotion Axis B Diag Message 10
D31A, SafeMotion Axis B Diag Message 11
D31B, SafeMotion Axis B Diag Message 12
D31C, SafeMotion Axis B Diag Message 13
D31D, SafeMotion Axis B Diag Message 14
D31E, SafeMotion Axis B Diag Message 15
D31F, SafeMotion Axis B Diag Message 16
D320, The Safety Control Task watchdog has bveen expired
00B1, Safety reports a 'Global Shutdown Error'
0115, Controller II: Maximum temperature exceeded. Temperature is 0xXX, should be <= 0xXX.
0117, Controller II: Temperature difference too high. Difference is II, should be <= II.
0118, Controller II: Maximum voltage alert (Partner_VCC). Voltage is 0xXX, should be <= 0xXX.
011A, Controller II: Maximum voltage alert (ECAT_VCC). Voltage is 0xXX, should be <= 0xXX.
102C, Unallowed Safe User Parameter Size for the requested features, Received=II Expected=II
3112, The activating or deactivating of groups is not allowed in PREOP
3115, FB CAMMON (Word-Offset 0xXX of the CfgData): The value of TDCLowerLimit (plus maximum position jitter) (II) is bigger or equal the configured position of 360° (II)
3117, FB CAMMON (Word-Offset 0xXX of the CfgData): The value of BDCUpperLimit (II) is smaller or equal the configured value of 180° (plus maximum position jitter) (II)
3118, FB CAMMON (Word-Offset 0xXX of the CfgData): The value of BDCLowerLimit (plus maximum position jitter) (II) is greater or equal the configured value of 180° (II)
311B, FB CAMMON (Word-Offset 0xXX of the CfgData): The value of TDC1UpperLimit (plus the maximum position jitter) (II) is bigger or equal the configured position of 360° (II)
3122, The Download of the Project CRC is not allowed in PREOP
3123, The Download of the Change Group Activation data is not allowed if customizing is not supported
3414, All groups will enter the ERROR-state because the CRC of the Cyclic FRAM Data was wrong
3417, All groups will enter the ERROR-state because the initialization of Cyclic FRAM Data was wrong
3418, Safe User Parameter from FRAM are not correct
38D0, FB II (ADVPOSMON): The referenced SafeDriveFeedback module (II) is not configured or has no Position Referencing enabled.
38D1, FB II (ADVPOSMON): The referenced SafeDriveFeedback module (II) reports error 0xXX.
4012, FB II (CAMMON): The Input BackwardsMove is TRUE while the Position is between 180° and 360°, the actual position is II
4015, FB II (CAMMON): The value of TDCLowerLimit (plus maximum position jitter) (II) is bigger or equal the configured position of 360° (II)
4017, FB II (CAMMON): The value of BDCUpperLimit (II) is smaller or equal the configured value of 180° (plus maximum position jitter) (II)
4018, FB II (CAMMON): The value of BDCLowerLimit (plus maximum position jitter) (II) is greater or equal the configured value of 180° (II)
401B, FB II (CAMMON): The value of TDC1UpperLimit (plus the maximum position jitter) (II) is bigger or equal the configured position of 360° (II)
D1B0, Primary MC: SAFETY FEEDBACK Module: 0xXX. Manual Referencing requires download of new Safe User Parameter.
D1B1, Primary MC: SAFETY FEEDBACK Module: 0xXX. FPGA type is not supported by current Firmware. Protocol reported: II II
D1B2, Primary MC: SAFETY FEEDBACK Module: 0xXX. EnDat3 Feedback is not supported by Hardware.
D1B3, Primary MC: SAFETY FEEDBACK Module: 0xXX. The stored encoder Id (II) did not match with the expected id (II). Maybe the axis is reversed.
D1B4, Primary MC: SAFETY FEEDBACK Module: 0xXX. 64bit calculation is needed for position verification and may result in long safety cycle execution time (Return Code: 0xXX).
D2B0, Secondary MC: SAFETY FEEDBACK Module: 0xXX. Manual Referencing requires download of new Safe User Parameter.
D2B1, Secondary MC: SAFETY FEEDBACK Module: 0xXX. FPGA type is not supported by current Firmware. Protocol reported: II II
D2B2, Secondary MC: SAFETY FEEDBACK Module: 0xXX. EnDat3 Feedback is not supported by Hardware.
D2B3, Secondary MC: SAFETY FEEDBACK Module: 0xXX. The stored encoder Id (II) did not match with the expected id (II). Maybe the axis is reversed.
D2B4, Secondary MC: SAFETY FEEDBACK Module: 0xXX. 64bit calculation is needed for position verification and may result in long safety cycle execution time (Return Code: 0xXX).
D320, The Safety Control Task watchdog has been expired
Diagmessages of module DeviceDebug
Diagmessages of module AxisMain
Diagmessages of module Interpolator
Diagmessages of module PositionControl
Diagmessages of module VelocityControl
Diagmessages of module VelocityControl2
Diagmessages of module BiquadFilter
Diagmessages of module TorqueControl
Diagmessages of module OCT rotary (Hiperface DSL)
Diagmessages of module EnDat 22 rotary
Diagmessages of module EnDat 22 linear
Diagmessages of module BiSS-C rotary
Diagmessages of module BiSS-C linear
Diagmessages of module SimulationRotary
Diagmessages of module SyncServoMotor
Diagmessages of module LinearMotor
Diagmessages of module AsynchronousMotor
Diagmessages of module AxisDebug
Diagmessages of module OCT linear (Hiperface DSL)
Diagmessages of module EnDat 3 rotary
Diagmessages of module EnDat 3 linear
AX86x0 | Power supply module - Diagnostic messages
AX2090-BW80 | External brake resistor
TE5910 | TC3 Motion Designer - Quick commissioning guide
AX2090-BW65 | External brake resistor IP65
AX8000 | Multi-axis servo system - Function description
AX2090-NF80 | Mains filter
AX8820 | Universal regenerative unit
AX5000 | Digital Compact Servo Drive
Distributed servo drives
Rotary servomotors
Translatory servomotors
Planetary gears
Transport systems
Compact drive technology
Archive
TwinCAT 3
TwinCAT 2
Industry Solutions
Search
News
Home