G-functions

G00

Rapid traverse

G01

Linear interpolation

G02

Circular interpolation, clockwise (cw.)

G03

Circular interpolation, counter-clockwise (ccw.)

G02/03

Helical interpolation

G04

Dwell

G08

Acceleration at block begin

G09

Deceleration at block end

G10

Feedrate constant

G11

Feedrate adapted

G12

Deselection of corner feed reduction

G13

Selection of corner feed reduction

G17

X-Y-plane

G18

Z-X-plane

G19

Y-Z-plane

G20

Deselection of mirroring

G21

Mirroring of programmed path on the Y-axis

G22

Mirroring of programmed path on the X-axis

G23

Superimposing of G21 and G22

G33

Thread cutting, uniform lead

G51

Selection of diameter programming

G52

Deselection of diameter programming

G53

Deselection of zero offsets

G54…G59

Selection of zero offsets

G60

Exact stop

G61

Polynom contouring

G63

Tapping

G70

Inch data input

G71

Metric data input

G80 – G89

Implicite subprogram calls

G90

Absolute dimensioning

G91

Incremental dimension (relative)

G92

Coordinate preset

G93

F-word for specifying machining time

G94

F-word for specifying the feedrate

G95

Feedrate in millimeter per revolution

G96

Constant cutting speed

G97

Specification of spindle speed in 1/min

G98

Set negative software limit switch

G99

Set positive software limit switch

G100

Measuring functions (Typ 1- 7)

G101

Inclusion of measuring offsets in shifts

G102

Extracting measuring offsets from shifts

G106

Measurement with movement to target point

G107

Deselection of block global edge banding

G108

Edge banding

G115

General influencing of look-ahead

G116

Manipulate look-ahead

G117

Switch on look-ahead (default)

G129

Weighting of rapid traverse velocity

G130

Axis-specific weighting of acceleration

G131

Axis group-specific weighting of acceleration

G132

Axis-specific weighting of ramp time

G133

Axis group-specific weighting of ramp time

G134

Axis group-specific weighting of geometrical ramp time

G159

Extended zero offsets

G160

Axis specific activation of zero offsets

G161*

Circle center point, absolute

G162**

Circle center point, relative

G163

Radius programming

G164

Circle center point offset off

G165

Circle center point offset on

G166

Override 100%

G193

Path related feed adaptation

G194

Weighting of maximum feed velocity

G196

Maximum spindle speed for G96

G200

Selection of manual mode without parallel interpolation

G201

Selection of manual mode with parallel interpolation

G202

Deselection of manual mode with parallel interpolation

G239

Direct selection/deselection of TRC without a block

G260

Deselection of polynom contouring

G261

Selection of polynom contouring

G293

Time related feed adaptation

G301

Inserting of chamfers

G302

Inserting of rounding

G310

Interruptible block (Measurement typ 5 - 6)

G351

Mirroring with axis information

G359

Deselection of exact stop

G360

Selection of exact stop

G800 – G819

Additional implicite subprogram calls

G900

Switching to deceleration after block end

G901

Deceleration after block end

*If G162 is active:

I Relative position of the circle center point in X-direction

J Relative position of the circle center point in Y-direction

K Relative position of the circle center point in Z-direction

**If G161 is active:

I Absolute position of the circle center point in X-direction

J Absolute position of the circle center point in Y-direction

K Absolute position of the circle center point in Z-direction