G functions (G..)

G00

Linear interpolation in rapid traverse

G01

Linear interpolation

G02

Clockwise circle (cw)

G03

Counter-clockwise circle (ccw)

G02 Z.. K..

Helical interpolation (cw)

G03 Z.. K..

Helical interpolation (ccw)

G04

Dwell time

G05

Tangential TRC selection/deselection

G08

Acceleration at block start

G09

Deceleration at block end

G10

Feed rate of TRC, constant

G11

Feed rate of TRC, adapted

G12

Deselecting corner deceleration

G13

Selecting corner deceleration

G17

Select working plane XY

G18

Select working plane ZX

G19

Select working plane YZ

G20

Deselect the mirroring function

G21

Mirror programmed paths on the Y axis

G22

Mirror programmed paths on the X axis

G23

Superimpose G21 and G22

G25

Linear transitions with TRC

G26

Circular transitions with TRC

G33

Thread cutting, uniform pitch

G40

Deselection of TRC/CRC

 

 

G41

Activate TRC/CRC on left of contour

 

 

G42

Activate TRC/CRC on left of contour

 

 

G51

Selection of diameter programming

G52

Deselection of diameter programming

G53

Deselect zero offsets

G54 - G59

Select zero offsets

G60

Exact stop

G61

Polynomial contouring

G63

Thread tapping without compensation chuck

G66

Synchronise cycle at block end

G68

Select contour rotation

G69

Deselect contour rotation

G70

Inputs in inches

G71

Inputs in metric units

G74

Homing

 

 

 

G80 - G89

Implicit subroutine calls

G90

Dimension systems, absolute dimension

G91

Incremental dimension (all parameters relative)

G92

Reference point offset

G93

Switching F word to machining time in seconds

G94

Switching F word to feed rate per minute

G95

Feed rate per revolution

 

 

G96

Switching S word to constant cutting velocity

G97

Switching S word to spindle speed

G98

Setting negative software limit switch

G99

Setting positive software limit switch

G100

Measuring functions

 

 

 

 

G101

Include measuring offset calculation in offset

G102

Extract measuring offset from offset

G106

Measurement run with motion to target point (Type 3)

G107

Deselect cross-block edge banding

G108

Edge banding

G112

Gear change

G115

Disabling look-ahead function

G116

Disabling the calculation of block transition velocity

G117

Enabling the complete look-ahead function

G127

Weighting of maximum velocity, axis-specific

G128

Weighting of maximum velocity, axis group-specific

G129

Weighting of rapid traverse velocity

G130

Axis-specific weighting of acceleration

G131

Axis group-specific weighting of acceleration for G01/G02/G03

G132

Axis-specific weighting of ramp time

G133

Axis group-specific weighting of ramp time for G01/G02/G03

G134

Axis group-specific weighting of geometrical ramp time

G135

Selecting feedforward control

 

 

G136

Specifying weighting of feedforward control

 

 

G137

Deselecting feedforward control

 

 

G138

Direct TRC selection/deselection

 

 

G139

Indirect TRC selection/deselection

 

 

 

 

G140

Deselecting contour masking

G141

Selecting contour masking

G150

Deselecting spline interpolation

 

 

G151

Selecting Akima spline interpolation

G159

Extended zero offset

G160

Enable/disable zero offsets axis-specific

G161

Specifying centre point for circle definition, absolute

G162

Specifying centre point for circle definition, relative (initial state)

G163

Radius programming

G164

Deselecting circle centre point correction

G165

Selecting circle centre point correction

G166

override

G167

Spindle override

 

 

G193

Path-related feed interpolation

G194

Switching F word to weighting of maximum feed rate

G196

Maximum spindle speed for G96

G200

Selecting manual mode without parallel interpolation

G201

Selecting manual mode with parallel interpolation

G202

Deselecting manual mode with parallel interpolation

G230

Axis-specific weighting of acceleration for G00

G231

Axis group-specific weighting of acceleration for G00

G232

Ramp time weighting G00, axis-specific

G233

Axis group-specific weighting of ramp time for G00

G236

Direct TRC selection/deselection on the path

 

 

G237

Perpendicular TRC selection/deselection

G238

Selecting inside corner of TRC

G239

Selecting/deselecting TRC directly without block

G260

Deselecting polynomial contouring

G261

Selecting polynomial contouring (at block end)

G293

Time-related feed interpolation

G301

Inserting chamfers

G302

Inserting roundings

G303

Arc in 3D space

G310

Measure with interruption and jump (G310) (Types 5,6)

G331

Tapping with pitch specification

G332

Tapping retraction with pitch specification

G333

Acceleration weighting with feedhold, axis-specific

 

G334

Acceleration weighting with feedhold, axis group-specific

 

G338

Ramp time weighting with feedhold, axis-specific

 

G339

Ramp time weighting with feedhold, axis group-specific

 

G351

Mirroring with axis specification

G359

Deselecting exact stop

G360

Selecting exact stop

G800..

Implicit subroutine calls (additional)

G900

Deceleration at block end

G901

Deceleration after block end