G00 | Linear interpolation in rapid traverse |
G01 | Linear interpolation |
G02 | Clockwise circle (cw) |
G03 | Counter-clockwise circle (ccw) |
G02 Z.. K.. | Helical interpolation (cw) |
G03 Z.. K.. | Helical interpolation (ccw) |
G04 | Dwell time |
G05 | Tangential TRC selection/deselection |
G08 | Acceleration at block start |
G09 | Deceleration at block end |
G10 | Feed rate of TRC, constant |
G11 | Feed rate of TRC, adapted |
G12 | Deselecting corner deceleration |
G13 | Selecting corner deceleration |
G17 | Select working plane XY |
G18 | Select working plane ZX |
G19 | Select working plane YZ |
G20 | Deselect the mirroring function |
G21 | Mirror programmed paths on the Y axis |
G22 | Mirror programmed paths on the X axis |
G23 | Superimpose G21 and G22 |
G25 | Linear transitions with TRC |
G26 | Circular transitions with TRC |
G33 | Thread cutting, uniform pitch |
G40 | Deselection of TRC/CRC |
| |
| |
G41 | Activate TRC/CRC on left of contour |
| |
| |
G42 | Activate TRC/CRC on left of contour |
| |
| |
G51 | Selection of diameter programming |
G52 | Deselection of diameter programming |
G53 | Deselect zero offsets |
G54 - G59 | Select zero offsets |
G60 | Exact stop |
G61 | Polynomial contouring |
G63 | Thread tapping without compensation chuck |
G66 | Synchronise cycle at block end |
G68 | Select contour rotation |
G69 | Deselect contour rotation |
G70 | Inputs in inches |
G71 | Inputs in metric units |
G74 | Homing |
| |
| |
| |
G80 - G89 | Implicit subroutine calls |
G90 | Dimension systems, absolute dimension |
G91 | Incremental dimension (all parameters relative) |
G92 | Reference point offset |
G93 | Switching F word to machining time in seconds |
G94 | Switching F word to feed rate per minute |
G95 | Feed rate per revolution |
| |
| |
G96 | Switching S word to constant cutting velocity |
G97 | Switching S word to spindle speed |
G98 | Setting negative software limit switch |
G99 | Setting positive software limit switch |
G100 | Measuring functions |
| |
| |
| |
| |
G101 | Include measuring offset calculation in offset |
G102 | Extract measuring offset from offset |
G106 | Measurement run with motion to target point (Type 3) |
G107 | Deselect cross-block edge banding |
G108 | Edge banding |
G112 | Gear change |
G115 | Disabling look-ahead function |
G116 | Disabling the calculation of block transition velocity |
G117 | Enabling the complete look-ahead function |
G127 | Weighting of maximum velocity, axis-specific |
G128 | Weighting of maximum velocity, axis group-specific |
G129 | Weighting of rapid traverse velocity |
G130 | Axis-specific weighting of acceleration |
G131 | Axis group-specific weighting of acceleration for G01/G02/G03 |
G132 | Axis-specific weighting of ramp time |
G133 | Axis group-specific weighting of ramp time for G01/G02/G03 |
G134 | Axis group-specific weighting of geometrical ramp time |
G135 | Selecting feedforward control |
| |
| |
G136 | Specifying weighting of feedforward control |
| |
| |
G137 | Deselecting feedforward control |
| |
| |
G138 | Direct TRC selection/deselection |
| |
| |
G139 | Indirect TRC selection/deselection |
| |
| |
| |
| |
G140 | Deselecting contour masking |
G141 | Selecting contour masking |
G150 | Deselecting spline interpolation |
| |
| |
G151 | Selecting Akima spline interpolation |
G159 | Extended zero offset |
G160 | Enable/disable zero offsets axis-specific |
G161 | Specifying centre point for circle definition, absolute |
G162 | Specifying centre point for circle definition, relative (initial state) |
G163 | Radius programming |
G164 | Deselecting circle centre point correction |
G165 | Selecting circle centre point correction |
G166 | override |
G167 | Spindle override |
| |
| |
G193 | Path-related feed interpolation |
G194 | Switching F word to weighting of maximum feed rate |
G196 | Maximum spindle speed for G96 |
G200 | Selecting manual mode without parallel interpolation |
G201 | Selecting manual mode with parallel interpolation |
G202 | Deselecting manual mode with parallel interpolation |
G230 | Axis-specific weighting of acceleration for G00 |
G231 | Axis group-specific weighting of acceleration for G00 |
G232 | Ramp time weighting G00, axis-specific |
G233 | Axis group-specific weighting of ramp time for G00 |
G236 | Direct TRC selection/deselection on the path |
| |
| |
G237 | Perpendicular TRC selection/deselection |
G238 | Selecting inside corner of TRC |
G239 | Selecting/deselecting TRC directly without block |
G260 | Deselecting polynomial contouring |
G261 | Selecting polynomial contouring (at block end) |
G293 | Time-related feed interpolation |
G301 | Inserting chamfers |
G302 | Inserting roundings |
G303 | Arc in 3D space |
G310 | Measure with interruption and jump (G310) (Types 5,6) |
G331 | Tapping with pitch specification |
G332 | Tapping retraction with pitch specification |
G333 | Acceleration weighting with feedhold, axis-specific | |
G334 | Acceleration weighting with feedhold, axis group-specific | |
G338 | Ramp time weighting with feedhold, axis-specific | |
G339 | Ramp time weighting with feedhold, axis group-specific | |
G351 | Mirroring with axis specification |
G359 | Deselecting exact stop |
G360 | Selecting exact stop |
G800.. | Implicit subroutine calls (additional) |
G900 | Deceleration at block end |
G901 | Deceleration after block end |