IDN 3043 (P-0-3043) Position Switch Polarity Parameter

With this IDN it is possible to select the polarity for each position switch flag to the corresponding flag bit ( IDN 59 ) or the digital output (refer to IDN 59 , IDN 3041 , 3042 and IDN 3044 ).

With this functionality it is possible to implement a cam function with a positive or negative polarity.

Application Example: Positive Cam Function

IDN 60 = 2/8 Revolution IDN 3041 0001Hex IDN 3042 = 0003Hex

IDN 61 = 3/8 Revolution IDN IDN 3043 = 0002Hex IDN 3044 = 0

IDN 3005 = 41 IDN 3007 = 0003Hex

Application Example: Negative Cam Function

IDN 60 = 2/8 Revolution IDN 3041 0001Hex IDN 3042 = 0003Hex

IDN 61 = 3/8 Revolution IDN IDN 3043 = 0001Hex IDN 3044 = 0

IDN 3005 = 40 IDN 3007 = 0003Hex

IDN 3043 (P-0-3043) Position Switch Polarity Parameter 1:
IDN 3043 (P-0-3043) Position Switch Polarity Parameter 2:

Data Length:

2 bytes

Non-Volatile:

Yes

Data Type:

Binary

Write Access:

CP2, CP3, CP4

Minimum:

0000H

Run-Up Check:

 

Maximum:

00FFH

Cyclic Transfer:

 

Default:

0

Serial Equiv:

WPOSP

Units:

 

Version:

5.04 

IDN Type:

PS

ADS Index Group (hex.):

0x8BE3

Definition

Bit

Description

Setting

LSB 0

 

Position switch point 1 ( IDN 60 )

 0= The flag will set to „1“ if the position feedback is greater than or equal to the position switch point.

 1 = The flag will set to „0“ if the position feedback value is smaller than the position switching point.

1

Position switch point 2 ( IDN 61 )

2

Position switch point 3 ( IDN 62 )

3

Position switch point 4 ( IDN 63 )

4

Position switch point 5 ( IDN 64 )

5

Position switch point 6 ( IDN 65 )

6

Position switch point 7 ( IDN 66 )

7

Position switch point 8 ( IDN 67 )

8-15

 

Reserved