Industrial PC
Fieldbus Components
Drive Technology
Servo drive
Distributed servo drives
Rotary servomotors
Translatory servomotors
Planetary gears
Transport systems
Compact drive technology
Accessories
Software
TE5910 | TC3 Motion Designer - Quick commissioning guide
AX8000 | Multi-axis servo system - Function description
AX5000 | Digital compact servo drives - Function description
AX5000 | Digital compact servo drives - IDN-Description
AX5000 | Digital compact servo drives - Diagnostic Messages
AX5000 EMC-Manual - Version 1.1
AX5000 Tuning-Guide - Version 1.0
AX8xxx | Axis module - Diagnostic messages
AX8xxx | Axis module - Object dictionary
AX86x0 | Power supply module - Object dictionary
AX86x0 | Power supply module - Diagnostic messages
Standard-Messages
0000, No errors
2310, Continuous over current (device output side), Operating time counter: UU s., Entry counter: UU
2380, Peak over current (device output side), Operating time counter: UU s., Entry counter: UU
23A0, Continuous over current (device output side)
3110, Mains over-voltage, Operating time counter: UU s., Entry counter: UU
3130, Phase failure, Operating time counter: UU s., Entry counter: UU
3180, Mains voltage over brake resistor operating voltage. Operating time counter: UU s., Entry counter: UU
3181, Wrong mains type. Operating time counter: UU s., Entry counter: UU
31A0, Mains over-voltage
31A1, Mains under-voltage
3210, DC link over-voltage, Operating time counter: UU s., Entry counter: UU
3280, Device DC link over-voltage, Operating time counter: UU s., Entry counter: UU
4210, Excess temperature device, Operating time counter: UU s., Entry counter: UU
42A0, Excess temperature device
5560, Read data failed: SS
5561, Missing data EEPROM: SS
556C, Write data failed: SS
5580, Read failure EEPROM Pcb ID UU
5582, Missing ids in EEPROM Pcb ID UU
5583, Missing device ids in eeprom. Operating time counter: UU s., Entry counter: UU
5587, Missing factory settings
5592, EEPROM Pcb ID UU FirmwareIndex is incompatible to this Firmware
5593, ESC EEPROM Pcb ID UU Structure Version is incompatible to this Firmware.
5598, Update BIC to SII Eeprom failed: SS
55A0, Read failure EEPROM. SS
55A1, Missing data EEPROM. SS
55D0, Restored Errormessages from persistent memory
55D1, Missing data EEPROM: SS
6010, Software reset (watchdog), Operating time counter: UU s., Entry counter: UU
6080, Failure config bits. Operating time counter: UU s., Entry counter: UU
6310, Loss of parameters, Operating time counter: UU s., Entry counter: UU
6320, Parameter error. Operating time counter: UU s., Entry counter: UU
6380, Parameter 0xXX/XX with parametrized 0xXX/XX is too low
6381, Parameter 0xXX/XX with parametrized 0xXX/XX is too high
6382, Value of parameter 0xXX/XX not supported
6383, Parameter error: SS
7111, Failure brake chopper, Operating time counter: UU s., Entry counter: UU
7112, Over current brake chopper, Operating time counter: UU s., Entry counter: UU
7180, Brake resistor not found. Operating time counter: UU s., Entry counter: UU
7181, Brake resistor power overload by DC link over-voltage. Operating time counter: UU s., Entry counter: UU
7182, Wrong xml file. Operating time counter: UU s., Entry counter: UU
7183, Brake resistor overloaded. Operating time counter: UU s., Entry counter: UU
7184, Chopper diode overloaded. Operating time counter: UU s., Entry counter: UU
71A0, Brake resistor overloaded
7580, I2C communication failure. Operating time counter: UU s., Entry counter: UU
FF01, Error reaction forced: Generative brake order
FF02, Error reaction forced: Non-generative brake order
FF03, Error reaction forced: Brake chopper off
FF07, Error reaction forced: Torque Off order
FF0B, Error reaction forced: NC handling order
FF1C, Load resistor overloaded with error reaction brake, Operating time counter: UU s., Entry counter: UU
FF1D, Load resistor overloaded with error reaction torque off, Operating time counter: UU s., Entry counter: UU
FFA0, Fan malfunction
FFC0, SS successfully done
FFD0, Debug firmware, replace "As soon as possible"!
FFD1, Dbg: SS
AX8820 | Universal regenerative unit - Diagnostic messages
AX8820 | Universal regenerative unit - Object Dictionary
AMP8000 | Distributed servo drives - Diagnostic messages
AMP8000 | Distributed servo drives - Object Dictionary
Archive
TwinCAT 3
TwinCAT 2
MX-System
Industry Solutions
Search
News
Home