
Industrial PC

Fieldbus Components

Drive Technology


Servo drive


Distributed servo drives


Rotary servomotors


Translatory servomotors


Planetary gears


Transport systems


Compact drive technology


Accessories


Software



TE5910 | TC3 Motion Designer - Quick commissioning guide



AX8000 | Multi-axis servo system - Function description



AX5000 | Digital compact servo drives - Function description



AX5000 | Digital compact servo drives - IDN-Description



AX5000 | Digital compact servo drives - Diagnostic Messages



AX5000 EMC-Manual - Version 1.1



AX5000 Tuning-Guide - Version 1.0



AX8xxx | Axis module - Diagnostic messages



AX8xxx | Axis module - Object dictionary



AX86x0 | Power supply module - Object dictionary



AX86x0 | Power supply module - Diagnostic messages




Standard-Messages





0000, No errors





2310, Continuous over current (device output side), Operating time counter: UU s., Entry counter: UU





2380, Peak over current (device output side), Operating time counter: UU s., Entry counter: UU





23A0, Continuous over current (device output side)





3110, Mains over-voltage, Operating time counter: UU s., Entry counter: UU





3130, Phase failure, Operating time counter: UU s., Entry counter: UU





3180, Mains voltage over brake resistor operating voltage. Operating time counter: UU s., Entry counter: UU





3181, Wrong mains type. Operating time counter: UU s., Entry counter: UU





31A0, Mains over-voltage





31A1, Mains under-voltage





3210, DC link over-voltage, Operating time counter: UU s., Entry counter: UU





3280, Device DC link over-voltage, Operating time counter: UU s., Entry counter: UU





4210, Excess temperature device, Operating time counter: UU s., Entry counter: UU





42A0, Excess temperature device





5560, Read data failed: SS





5561, Missing data EEPROM: SS





556C, Write data failed: SS





5580, Read failure EEPROM Pcb ID UU





5582, Missing ids in EEPROM Pcb ID UU





5583, Missing device ids in eeprom. Operating time counter: UU s., Entry counter: UU





5587, Missing factory settings





5592, EEPROM Pcb ID UU FirmwareIndex is incompatible to this Firmware





5593, ESC EEPROM Pcb ID UU Structure Version is incompatible to this Firmware.





5598, Update BIC to SII Eeprom failed: SS





55A0, Read failure EEPROM. SS





55A1, Missing data EEPROM. SS





55D0, Restored Errormessages from persistent memory





55D1, Missing data EEPROM: SS





6010, Software reset (watchdog), Operating time counter: UU s., Entry counter: UU





6080, Failure config bits. Operating time counter: UU s., Entry counter: UU





6310, Loss of parameters, Operating time counter: UU s., Entry counter: UU





6320, Parameter error. Operating time counter: UU s., Entry counter: UU





6380, Parameter 0xXX/XX with parametrized 0xXX/XX is too low





6381, Parameter 0xXX/XX with parametrized 0xXX/XX is too high





6382, Value of parameter 0xXX/XX not supported





6383, Parameter error: SS





7111, Failure brake chopper, Operating time counter: UU s., Entry counter: UU





7112, Over current brake chopper, Operating time counter: UU s., Entry counter: UU





7180, Brake resistor not found. Operating time counter: UU s., Entry counter: UU





7181, Brake resistor power overload by DC link over-voltage. Operating time counter: UU s., Entry counter: UU





7182, Wrong xml file. Operating time counter: UU s., Entry counter: UU





7183, Brake resistor overloaded. Operating time counter: UU s., Entry counter: UU





7184, Chopper diode overloaded. Operating time counter: UU s., Entry counter: UU





71A0, Brake resistor overloaded





7580, I2C communication failure. Operating time counter: UU s., Entry counter: UU





FF01, Error reaction forced: Generative brake order





FF02, Error reaction forced: Non-generative brake order





FF03, Error reaction forced: Brake chopper off





FF07, Error reaction forced: Torque Off order





FF0B, Error reaction forced: NC handling order





FF1C, Load resistor overloaded with error reaction brake, Operating time counter: UU s., Entry counter: UU





FF1D, Load resistor overloaded with error reaction torque off, Operating time counter: UU s., Entry counter: UU





FFA0, Fan malfunction





FFC0, SS successfully done





FFD0, Debug firmware, replace "As soon as possible"!





FFD1, Dbg: SS



AX8820 | Universal regenerative unit - Diagnostic messages



AX8820 | Universal regenerative unit - Object Dictionary



AMP8000 | Distributed servo drives - Diagnostic messages



AMP8000 | Distributed servo drives - Object Dictionary


Archive

TwinCAT 3

TwinCAT 2

MX-System

Industry Solutions

Search

News

Home