General command overview
Command  | Description  | block-by-block /   | Default  | 
|---|---|---|---|
Contour line programming (angle)  | s  | 
  | |
Rotation additive  | m  | 
  | |
Calculates the inverse rotation of a vector  | s  | 
  | |
Calculates the rotation of a vector  | s  | 
  | |
Bottleneck detection off  | m  | Default  | |
Bottleneck detection on  | m  | 
  | |
Constant velocity at the contour  | m  | Default  | |
Constant velocity in the interior circle  | m  | 
  | |
Constant velocity of tool center point  | m  | 
  | |
Circular interpolation  | s  | 
  | |
Centre point correction off  | m  | 
  | |
Centre point correction on  | m  | Default  | |
Delete Distance to Go  | s  | 
  | |
Dynamic Override  | m  | 
  | |
Constant feed programming  | m  | Default  | |
Linear feed programming  | m  | 
  | |
Rapid traverse  | m  | 
  | |
Straight line interpolation  | m  | Default  | |
Clockwise circular interpolation  | m  | 
  | |
Anticlockwise circular interpolation  | m  | 
  | |
Dwell time  | s  | 
  | |
Accurate stop  | s  | 
  | |
Plane selection XY  | m  | Default  | |
Plane selection ZX  | m  | 
  | |
Plane selection YZ  | m  | 
  | |
No miller/cutter radius compensation  | m  | Default  | |
Miller/cutter radius compensation left  | m  | 
  | |
Miller/cutter radius compensation right  | m  | 
  | |
Zero shift suppression  | m  | Default  | |
1st adjustable zero shift  | m  | 
  | |
2nd adjustable zero shift  | m  | 
  | |
3rd adjustable zero shift  | m  | 
  | |
4th adjustable zero shift  | m  | 
  | |
1st programmable zero shift  | m  | 
  | |
2nd programmable zero shift  | m  | 
  | |
Accurate stop  | m  | 
  | |
Dimensions inch  | m  | 
  | |
Dimensions metric  | m  | Default  | |
Programmed traverse to reference point  | s  | 
  | |
Reference dimension notation  | m  | Default  | |
Incremental dimension notation  | m  | 
  | |
Dimensions in inches with calculation of the feed  | m  | 
  | |
Dimensions metric with calculation of the feed  | m  | 
  | |
Mirroring coordinate system  | m  | 
  | |
Modulo movement  | s  | 
  | |
Messages from the NC program  | s  | 
  | |
orthogonal approach of and departure from the contour  | s  | 
  | |
Feed direction positive  | m  | Default  | |
Feed direction negative  | m  | 
  | |
Automatic Accurate Stop  | m  | 
  | |
Parameterization of the axis dynamics  | m  | 
  | |
C1 reduction factor  | m  | 
  | |
C2 reduction factor  | m  | 
  | |
Circular smoothing  | m  | 
  | |
C0 reduction - deflection angle  | m  | 
  | |
Circular smoothing (old)  | m  | 
  | |
Pathway dynamics (old)  | m  | 
  | |
Pathway dynamics  | m  | 
  | |
Circular accuracy  | m  | 
  | |
Smoothing with Bezier Splines  | m  | 
  | |
Smoothing of Segment Transitions  | m  | 
  | |
C0 reduction - max. step change in velocity  | m  | 
  | |
Minimum velocity  | m  | 
  | |
Parameterization of the configurable zero shift  | m  | 
  | |
Reads the actual position  | s  | 
  | |
Absolute rotation  | m  | 
  | |
Extended rotation function off  | m  | Default  | |
Extended rotation function on  | m  | 
  | |
Calculation routine for rotating a vector  | s  | 
  | |
Initialization of R-parameters  | s  | 
  | |
Converts an R-parameter to DWord and checks whether a defined bit is set  | m  | 
  | |
Contour line programming (segment length)  | s  | 
  | |
Skip virtual movements  | m  | 
  | |
Cartesian tool displacement and length compensation is not applied under G91  | m  | 
  | |
Cartesian tool displacement and length compensation is applied under G91  | m  | Default  | |
Writing and reading of tool parameters  | m  | 
  | |
Target position monitoring  | s  | 
  | |
Zero shift is not applied under G91  | m  | 
  | |
Zero shift is applied under G91  | m  | Default  | 
Address  | Description  | 
|---|---|
Axis label for auxiliary axis ( 1 <= n <= 5)  |