ANOUT2
ASCII - Command | ANOUT2 |
|
| |
Syntax Transmit | ANOUT2 [Data] |
|
| |
Syntax Receive | ANOUT2 <Data> | Available in |
| |
Type | Variable rw | MMI | Yes | |
ASCII Format | Integer8 | CANBus Object Number | 350E (hex) | |
DIM | - | PROFIBUS PNU | 1614 (dec) IND = 0000xxxx (bin) | |
Range | 0 .. 8 | DPR | 14 (dec) | |
Default | 2 |
| ||
Opmode | All | Data Type Bus/DPR | Integer8 | |
Drive State | Disabled + Reset (Coldstart) | Weightning |
| |
Start Firmware | 1.20 |
| ||
Configuration | Yes | Revision | 1.8 | |
Function Group | Analog I/O | EEPROM | Yes | |
Short Description | Source of the Analog Output 2 |
Description
Configuration of analog output 2. The actual value is read via MONITOR2. The output provides various analog setpoint values or actual values, depending on the selection in the operator software. Output resistor 2.2kOhm. Resolution 10 bit.
Status | Description |
---|---|
ANOUT2=0 | No output voltage at Analog Output 2. |
ANOUT2=1 | Outputs the actual velocity (10V = VLIM). |
ANOUT2=2 | Outputs the actual current (10V = IPEAK). |
ANOUT2=3 | Outputs the velocity setpoint (10V = VLIM). |
ANOUT2=4 | Outputs the current setpoint (10V = IPEAK). |
ANOUT2=5 | Outputs the actual contouring error (10V = PEMAX). |
ANOUT2=6 | Outputs a value given by a option DPR-slotboard. |
ANOUT2=7 | The actual position is at the analog output. |
ANOUT2=8 | The analog output gives a constant voltage. The voltage can be set by using the help variable AN2TRIG in mV (starting with firmware 4.91) |