TwinCAT 3.1 Build 4026
The following new properties and features are available with TwinCAT 3.1 Build 4026.
Category | Feature | Further information | Available from Build Revision |
|---|---|---|---|
Development support | Cross Reference List: New "Context" column | 4026.0 | |
List components: Extension of the function with categories and highlighting of the entered characters. | 4026.0 | ||
Smart tag function: Simple declaration of variables from the implementation part. | 4026.0 | ||
PLC Bookmarks | 4026.0 | ||
ST editor | Dark Theme (offline) | 4026.0 | |
Highlighting of all places of use of the variable on which the cursor is placed. | 4026.0 | ||
Incremental search | 4026.0 | ||
Rectangle selection | 4026.0 | ||
CFC editor | Setting for execution order Default: Automatic data flow mode | 4026.0 | |
Temporary display of the execution order | 4026.0 | ||
Easier insertion of multiple elements from the toolbox | 4026.0 | ||
Drag and drop of variables and objects from the declaration section and from the Solution Explorer | 4026.0 | ||
Changing the pin arrangement via drag and drop | 4026.0 | ||
Object-orientated programming | For input parameters with initial value, no variables have to be passed in a call. | 4026.0 | |
IntelliSense for additional FB_init parameters | 4026.0 | ||
Online features | Structured representation of inherited variables | 4026.0 | |
"Go to implementation" and "Go to reference" commands | 4026.0 | ||
Filter option in the "Select online status" dialog | 4026.0 | ||
Unterstützung von __TRY, __CATCH, __FINALLY, __ENDTRY für 64 Bit Laufzeitsysteme | 4026.0 | ||
Libraries | Use of a PLC project as referenced library. | 4026.0 | |
New options for libraries in the PLC project properties: "Allow implicit checks for compiled libraries" and "Force Qualified_only for library access". | 4026.0 | ||
Improve navigation in the library manager through linking. | 4026.0 | ||
Ability to activate and deactivate repositories in the library manager. | 4026.0 | ||
Distinguish between the commands for adding placeholders and libraries. | 4026.0 | ||
Multiple selection in the "Add Library" dialog | 4026.0 | ||
Export of the values of a parameter list as .csv file | 4026.0 | ||
Operators, variables and data types | Determine the name of local objects with the __POUNAME operator and the line number with the __POSITION operator. | 4026.0 | |
Generic constants | 4026.0 | ||
New data types:
| 4026.0 | ||
XSIZEOF | 4026.0 | ||
Interpretation of a literal as UTF8 using the UTF8# prefix | 4026.0 | ||
Miscellaneous | Representation of the type system: Library Tc3_Global_Types ExternalTypes.tmc instead of the External Types folder | 4026.0 | |
Save PLC projects as reusable project templates. | 4026.0 |