Objects for parameterization
Index 8000: AI Acc Settings X
Index (hex) | Name | Meaning | Data type | Flags | Default |
---|---|---|---|---|---|
8000:0 | AI Acc Settings X | Settings for the acceleration axis X | UINT8 | RO | 0x1E (30dec) |
8000:06 | Enable filter | Enables the measured value filter. See chapter Measured value filter. | BOOLEAN | RW | 0x00 (0dec) |
8000:0B | Enable vendor calibration | Enables the scaling of the measured values to mg/LSB. See chapter Measured value resolution. | BOOLEAN | RW | 0x01 (1dec) |
8000:15 | Filter settings | Selection of the measured value filter. See chapter Measured value filter. | UINT16 | RW | 0x0002 (2dec) |
8000:1E | Slope detection sensitivity | Controls the sensitivity of the status display. See chapter Status display. | UINT16 | RW | 0x0002 (2dec) |
Index 8010: AI Acc Settings Y
Index (hex) | Name | Meaning | Data type | Flags | Default |
---|---|---|---|---|---|
8010:0 | AI Acc Settings Y | Settings for the acceleration axis Y | UINT8 | RO | 0x1E (30dec) |
8010:06 | Enable filter | Enables the measured value filter. See chapter Measured value filter. | BOOLEAN | RW | 0x00 (0dec) |
8010:0B | Enable vendor calibration | Enables the scaling of the measured values to mg/LSB. See chapter Measured value resolution. | BOOLEAN | RW | 0x01 (1dec) |
8010:15 | Filter settings | Selection of the measured value filter. See chapter Measured value filter. | UINT16 | RW | 0x0002 (2dec) |
8010:1E | Slope detection sensitivity | Controls the sensitivity of the status display. See chapter Status display. | UINT16 | RW | 0x0002 (2dec) |
Index 8020: AI Acc Settings Z
Index (hex) | Name | Meaning | Data type | Flags | Default |
---|---|---|---|---|---|
8020:0 | AI Acc Settings Z | Settings for the acceleration axis Z | UINT8 | RO | 0x1E (30dec) |
8020:06 | Enable filter | Enables the measured value filter. See chapter Measured value filter. | BOOLEAN | RW | 0x00 (0dec) |
8020:0B | Enable vendor calibration | Enables the scaling of the measured values to mg/LSB. See chapter Measured value resolution. | BOOLEAN | RW | 0x01 (1dec) |
8020:15 | Filter settings | Selection of the measured value filter. See chapter Measured value filter. | UINT16 | RW | 0x0002 (2dec) |
8020:1E | Slope detection sensitivity | Controls the sensitivity of the status display. See chapter Status display. | UINT16 | RW | 0x0002 (2dec) |
Index F800: SAI Settings
Index (hex) | Name | Meaning | Data type | Flags | Default |
---|---|---|---|---|---|
800F:0 | SAI Settings |
| UINT8 | RO | 0x11 (17dec) |
F800:0D | Sampling rate | From Firmware 03 Selection of the sampling rate. See chapter Sampling rate. | UINT16 | RW | 0x0000 (0dec) |
800F:11 | Range | Selection of the measuring range. See chapter Measuring range. | UINT16 | RW | 0x0000 (0dec) |