AX5021-0000 brake module

Order no. | Description |
|---|---|
AX5021-0000-0000 | Using a brake module, additional braking power can be taken up in a drive system, because connecting an external braking resistor without a brake module in a drive system with devices up to max. 25 A rated current is not permissible. The brake module also offers further advantages: installation is easy and it is compact and does not take up much space. The brake module is equipped with a complete DC link and an internal braking resistor and enables connection of an external braking resistor with the integrated brake chopper. Several brake modules can be integrated into a drive system. |
![]() | Operating conditions The brake module may only be used together with servo drives from the AX51xx-xxxx-02xx and AX52xx-xxxx-02xx series; these devices have a serial number >100,000. In addition to the AX5021, the drive system must also include at least two other servo drives from the AX5000 series! |