Option: Adaptive weighting of acceleration (P-AXIS-00501)

P-AXIS-00501

Option: Adaptive weighting of acceleration

Description

To reduce a possible oscillation the acceleration can be reduced for small deviations.

Parameter

kenngr.dist_ctrl[i].use_adaptive_acceleration (where i=0)

Data type

BOOLEAN

Data range

0: No adaptive weighting of acceleration

1: Adaptive weighting of acceleration active

Axis types

T, R

Dimension

T: ----

R: ----

Default value

0

Drive types

SERCOS, Profidrive, CANopen

Remarks

In addition the following limits for acceleration and distance error must be configured: P-AXIS-00502 or P-AXIS-00416 and P-AXIS-00504 or P-AXIS-00505

 

Available as of Build V3.1.3080.12 or V3.1.3107.44

For compatibility reasons, the parameter

kenngr.distc.use_adaptive_acceleration

continues to be available.

Option: Adaptive weighting of acceleration (P-AXIS-00501) 1:
Parameters for acceleration and distance error