Error messages of the mxA interface in the submit interpreter
|
No. |
Message text |
Cause |
Remedy |
|---|---|---|---|
|
401 |
INTERNAL ERROR |
Internal exceptional error |
Contact KUKA Deutschland GmbH. (>>> KUKA Service) |
|
402 |
ASSERT FAILED |
Internal exceptional error | |
|
403 |
INVALID COMMAND ID |
Internal exceptional error | |
|
404 |
INVALID COMMAND STATE |
Internal exceptional error | |
|
405 |
OVERFLOW COMMAND QUEUE |
Internal exceptional error | |
|
406 |
INVALID COMMAND QUEUE INDEX |
Internal exceptional error | |
|
407 |
INVALID COMMAND (PRE) QUEUE INDEX |
Internal exceptional error | |
|
408 |
INVALID WRITE_Q_IDX AND WRITE_PRE_Q_IDX |
Internal exceptional error | |
|
409 |
OVERFLOW STATUS RETURN QUEUE (SUBMIT) |
There are more than 100 checkback signals relating to status changes waiting to be transferred from the robot controller to the PLC. The transmission rate is considerably lower than the processing speed. |
Reduce the number of statements to be buffered simultaneously. If this is not possible, contact KUKA Deutschland GmbH. (>>> KUKA Service) |
|
410 |
INVALID FIELDBUS TELEGRAM LENGTH |
Internal exceptional error |
Contact KUKA Deutschland GmbH. (>>> KUKA Service) |
|
411 |
TIMEOUT ABORT_REQUEST |
Internal exceptional error | |
|
412 |
INVALID CHECKSUM PLC -> KRC |
The checksum for data transmission from the PLC to the robot controller is invalid: | |
|
Error during start-up:
|
Check configuration in iiQWorks.Sim and CODESYS and configure PROFINET correctly. | ||
|
Error during operation:
|
Contact KUKA Deutschland GmbH. (>>> KUKA Service) | ||
|
413 |
INVALID MOVE TYPE |
Internal exceptional error |
Contact KUKA Deutschland GmbH. (>>> KUKA Service) |
|
414 |
TIMEOUT HEARTBEAT FROM PLC |
Connection to PLC interrupted |
Restore connection, then acknowledge error. |
|
PLC program stopped |
Restart the PLC program. | ||
|
Submit interpreter deselected or stopped |
Restart submit interpreter. | ||
|
Connecting cable defective or not correctly connected |
Exchange connecting cable or connect it correctly. | ||
|
416 |
SYS VAR NOT INITIALIZED |
An error occurred when reading a system variable. The specified system variable does not exist or may not be read in the current operating state. Example: $POS_ACT cannot be accessed until a BCO run has been carried out. | |
|
417 |
UNDERFLOW OF NIBBLE |
Internal exceptional error |
Contact KUKA Deutschland GmbH. (>>> KUKA Service) |
|
418 |
OVERFLOW OF NIBBLE |
Internal exceptional error | |
|
419 |
UNDERFLOW OF BYTE |
Internal exceptional error | |
|
420 |
OVERFLOW OF BYTE |
Internal exceptional error | |
|
421 |
UNDERFLOW OF INT16 |
Internal exceptional error | |
|
422 |
OVERFLOW OF INT16 |
Internal exceptional error | |
|
423 |
UNDERFLOW OF INT32 |
Internal exceptional error | |
|
424 |
OVERFLOW OF INT32 |
Internal exceptional error | |
|
425 |
UNDERFLOW OF REAL |
Internal exceptional error | |
|
426 |
OVERFLOW OF REAL |
Internal exceptional error | |
|
430 |
INVALID PTP APO |
An invalid approximation parameter has been transferred for a PTP motion. |
Program a valid value (parameter Approximate). (>>> APO) |
|
431 |
INVALID CP APO |
An invalid approximation parameter has been transferred for a CP motion (LIN, CIRC). | |
|
432 |
INVALID BASE NUMBER |
An invalid number has been programmed in the function block KRC_ReadBaseData or KRC_WriteBaseData for the BASE coordinate system. |
Specify the number of the BASE coordinate system that is currently being used in the robot controller (parameter BaseNo).
|
|
An invalid number has been programmed in a KRC_Move or KRC_Jog function block for the BASE coordinate system. |
Specify the number of the BASE coordinate system that is currently being used in the robot controller (parameter CoordinateSystem – COORDSYS.Base). (>>> COORDSYS) | ||
|
433 |
INVALID TOOL NUMBER |
An invalid number has been programmed in the function block KRC_ReadToolData or KRC_WriteToolData for the TOOL coordinate system. |
Specify the number of the TOOL coordinate system that is currently being used in the robot controller (parameter ToolNo).
|
|
An invalid number has been programmed in a KRC_Move or KRC_Jog function block for the TOOL coordinate system. |
Specify the number of the TOOL coordinate system that is currently being used in the robot controller (parameter CoordinateSystem – COORDSYS.Tool). (>>> COORDSYS) | ||
|
434 |
INVALID VELOCITY |
An invalid value has been programmed in a function block for the speed. |
Program a valid value (parameter Velocity):
|
|
435 |
INVALID ACCELERATION |
An invalid value has been programmed in a function block for the acceleration. |
Program a valid value (parameter Acceleration):
|
|
436 |
INVALID C_PTP |
An invalid approximation distance has been transferred for a PTP motion. |
Program a valid value (parameter Approximate). (>>> APO) |
|
437 |
INVALID C_DIS |
An invalid distance parameter has been transferred for an approximated motion. | |
|
438 |
INVALID C_VEL |
An invalid speed parameter has been transferred for an approximated motion. | |
|
439 |
INVALID C_ORI |
An invalid orientation parameter has been transferred for an approximated motion. | |
|
440 |
INVALID ORI_TYPE |
An invalid value has been programmed in a KRC_Move or KRC_Jog function block for the orientation control of the TCP. |
Program a valid value (parameter OriType). (>>> OriType) |
|
441 |
POSITION DATA NOT INITIALIZED |
No target position transferred when calling a KRC_Move function block. |
Define at least 1 element of the target position (parameter Position). (>>> E6POS) |
|
442 |
AXISPOSITION DATA NOT INITIALIZED |
No axis position transferred when calling a KRC_MoveAxis function block. |
Define at least 1 axis position (parameter AxisPosition). (>>> E6AXIS) |
|
443 |
INVALID TRIGGER DISTANCE |
An invalid value has been programmed in the KRC_SetDistanceTrigger function block for the switching point of the trigger. |
Program a valid value (parameter Distance):
|
|
444 |
INVALID TRIGGER IO |
An invalid output has been programmed in a KRC_SetDistanceTrigger or KRC_SetPathTrigger function block. |
Program a valid value (parameter Output):
|
|
445 |
INVALID TRIGGER PULSE |
An invalid value has been programmed in a KRC_SetDistanceTrigger or KRC_SetPathTrigger function block for the length of the pulse. |
Program a valid value (parameter Pulse):
|
|
446 |
INVALID CIRC_HP |
No auxiliary position transferred when calling a KRC_MoveCirc function block. |
Define at least 1 element of the auxiliary position (parameter CircHP). (>>> E6AXIS) |
|
447 |
INVALID INTERRUPT IO |
The number of the digital input to which the interrupt is declared is invalid (function block KRC_DeclareInterrupt). |
Program a valid value (parameter Input):
|
|
448 |
INVALID INTERRUPT NUMBER/ PRIORITY |
An invalid number was transferred when calling a KRC_…Interrupt function block. |
Program a valid value (parameter Interrupt):
|
|
449 |
INTERRUPT NOT DECLARED |
Interrupt has not been declared. |
Declare interrupt. (>>> Declaring interrupts) |
|
450 |
INVALID INTERRUPT ACTION |
The interrupt reaction programmed when the interrupt was declared is invalid. |
Program a valid reaction (parameter Reaction) (>>> Declaring interrupts) |
|
451 |
INVALID IO NUMBER |
The number of the digital input to which the interrupt is declared is invalid (function block KRC_DeclareInterrupt). |
Program a valid value (parameter Input):
|
|
452 |
INVALID PULSE DURATION |
An invalid value has been programmed in the function block KRC_WriteDigitalOutput for the length of the pulse. |
Program a valid value (parameter Pulse):
(>>> Writing a digital output) |
|
453 |
INVALID BUFFER_MODE |
An invalid BufferMode has been programmed in a function block. For example , DIRECT mode is not available for some function blocks. |
Program a valid BufferMode. (>>> BufferMode) |
|
454 |
INVALID TOOL NUMBER FOR LOAD_DATA |
An invalid number has been programmed in the function block KRC_ReadLoadData or KRC_WriteLoadData for reading or writing the load data or supplementary load data. |
Program a valid value (parameter Tool). (>>> Reading the load data) (>>> Writing load data) |
|
455 |
INVALID ANALOG IO NUMBER |
An invalid number has been programmed for the analog input or output in a function block. |
Program a valid number (parameter Number):
|
|
456 |
INVALID IPO_MODE |
An invalid value has been programmed in a function block for the interpolation mode, e.g. in a KRC_Move function block. |
Program a valid value (parameter CoordinateSystem – COORDSYS.IPO_MODE). (>>> COORDSYS) |
|
457 |
INVALID CIRC_TYPE |
An invalid value has been programmed in a KRC_MoveCirc function block for the orientation control during the circular motion. |
Program a valid value (parameter CircType). (>>> CircType) |
|
458 |
INVALID FRAME DATA |
Invalid TOOL or BASE data have been programmed in a KRC_WriteToolData or KRC_WriteBaseData function block. |
Program valid data (parameter ToolData or BaseData). (>>> Writing TOOL data) (>>> Writing BASE data) |
|
459 |
INVALID LOAD DATA |
Invalid load data have been programmed in a KRC_WriteLoadData function block. |
Program valid data. (>>> Writing load data) |
|
460 |
INVALID SOFT_END (REVERSED) |
Error writing the software limit switches: Positive software limit switch < negative software limit switch |
Program lower values for the negative software limit switch than for the positive software limit switch. |
|
461 |
INVALID INTERRUPT STATE |
Internal exceptional error |
Contact KUKA Deutschland GmbH. (>>> KUKA Service) |
|
462 |
INVALID SYS VAR INDEX |
An index for which no system variable is stored has been transferred in a KRC_ReadSysVar or KRC_WriteSysVar function block. |
Program a valid value (parameter Index). (>>> Reading system variables) (>>> Writing system variables) |
|
463 |
INVALID SYS VAR VALUE |
An invalid value has been programmed in a KRC_WriteSysVar function block for the system variable. |
Program a valid value (parameter Value1 … Value10). (>>> Writing system variables) |
|
464 |
SYS VAR NOT WRITEABLE |
An error occurred when writing a system variable. The specified system variable does not exist or may not be written in the current operating state. | |
|
465 |
INVALID REAL VALUE |
The programmed Real value is invalid. |
Program a valid value:
|
|
466 |
ERROR SETTING OUTPUT |
Error writing an output. The output may already be assigned by the system. |
Use a different digital output (parameter Number):
|
|
467 |
ERROR SETTING SOFTEND |
An error occurred when writing a software limit switch. One possible error, for example, is writing a rotational axis with a value outside the range +/-360°. |
Program valid values for the software limit switches (see machine data). |
|
468 |
INVALID TECH FUNCTION INDEX |
A TechFunctionID for which no technology function is stored has been transferred in a KRC_TechFunction function block. |
Contact KUKA Deutschland GmbH. (>>> KUKA Service) |
|
469 |
INVALID TECH FUNCTION PARAMETER |
An invalid value has been programmed in a KRC_TechFunction function block for a parameter. |
Contact KUKA Deutschland GmbH. (>>> KUKA Service) |
|
470 |
INVALID PARAMETER VALUE |
An invalid value has been programmed in the called function block for one or more parameters. |
Program valid values for the parameters. |
|
471 |
PDAT NOT INITIALIZED |
No PDAT data were transferred on calling a KRC_ForwardAdvanced or KRC_InverseAdvanced function block. |
Define at least 1 element of PDAT_ACT. |
|
472 |
FDAT NOT INITIALIZED |
No FDAT data were transferred on calling a KRC_ForwardAdvanced or KRC_InverseAdvanced function block. |
Define at least 1 element of FDAT_ACT. |
|
473 |
LDAT NOT INITIALIZED |
No LDAT data were transferred on calling a KRC_ForwardAdvanced or KRC_InverseAdvanced function block. |
Define at least 1 element of LDAT_ACT. |
|
474 |
INVALID TOOL OR BASE NUMBER |
An invalid number has been programmed in the KRC_ForwardAdvanced or KRC_InverseAdvanced function block for the TOOL coordinate system or for the BASE coordinate system. |
Specify the number of the TOOL coordinate system that is currently being used in the robot controller (parameter Tool).
Specify the number of the BASE coordinate system that is currently being used in the robot controller (parameter Base).
|