Writing load data
Description
The function block KRC_WriteLoadData writes the load data of the robot (payload data or supplementary load data).
Inputs
Parameter | Type | Description |
|---|---|---|
AxisGroupIdx | INT | Index of axis group
|
ExecuteCmd | BOOL | The statement is executed in the case of a rising edge of the signal. |
Tool | INT | Number of the TOOL coordinate system for writing the payload data or number for writing the supplementary load data
|
M | REAL | Mass |
X, Y, Z | REAL | Position of the center of gravity relative to the flange |
A, B, C | REAL | Orientation of the principal inertia axes relative to the flange |
JX, JY, JZ | REAL | Mass moments of inertia |
BufferMode | INT | Mode in which the statement is executed
(>>> BufferMode) |
Outputs
Parameter | Type | Description |
|---|---|---|
Busy | BOOL | TRUE = statement is currently being transferred or has already been transferred |
Done | BOOL | TRUE = statement has been executed |
Aborted | BOOL | TRUE = statement has been aborted |
Error | BOOL | TRUE = error in function block |
ErrorID | DINT | Error number |
OrderID | DINT | OrderID number |