Writing system variables
Description
The function block KRC_WriteSysVar can be used to write system variables.
Inputs
Parameter | Type | Description |
|---|---|---|
AxisGroupIdx | INT | Index of axis group
|
ExecuteCmd | BOOL | The statement is executed in the case of a rising edge of the signal. |
Index | INT | Index of the system variable
|
Value1 … Value10 | REAL | Value of the system variable If the system variable is a structure type, up to 10 components of the structure can be written. |
bContinue | BOOL | TRUE = write to system variable without advance run stop Note: Only possible for specific system variables. |
BufferMode | INT | Mode in which the statement is executed
(>>> BufferMode) |
![]() | So far, only the system variable $ADVANCE can be written. If required for the customer-specific application, the list of writable system variables can be expanded by KUKA. |
Outputs
Parameter | Type | Description |
|---|---|---|
Busy | BOOL | TRUE = statement is currently being transferred or has already been transferred |
Done | BOOL | TRUE = statement has been executed |
Aborted | BOOL | TRUE = statement has been aborted |
Error | BOOL | TRUE = error in function block |
ErrorID | DINT | Error number |
OrderID | DINT | OrderID number |