Input signals
AxisGroupIdx
This signal input is used to set the number of the robot addressed by a function block.
Execute
If this signal is set, mxAutomation transfers the associated function block to the robot. The function block is stored in a statement buffer by the robot, provided there is still sufficient space in the buffer. If the Execute input is reset, mxAutomation deletes the function block from the buffer again unless execution of the statement has already begun.
QueueMode
Mode in which a statement is executed on the robot controller
|
Value |
Name |
Description |
|---|---|---|
|
0 |
DIRECT |
The statement is executed directly by the submit interpreter (Submit program). Note: This mode is not available for certain function blocks. |
|
1 |
ABORTING |
The statement is executed immediately by the robot interpreter (main program). First, all active motions and buffered statements are aborted and the robot is braked to a standstill. |
|
2 |
BUFFERED |
The statement is buffered. Buffered statements are executed by the robot interpreter (main program) according to the FIFO principle. |
CircType
Orientation control for circular motion
|
Value |
Name |
Description |
|---|---|---|
|
0 |
BASE |
Base-related orientation control during a circular motion |
|
1 |
PATH |
Path-related orientation control during a circular motion |
OriType
Orientation control for the TCP
|
Value |
Name |
Description |
|---|---|---|
|
0 |
VAR |
The orientation of the TCP changes continuously during the motion. |
|
1 |
CONSTANT |
The orientation of the TCP remains constant during the motion. |
|
2 |
JOINT |
The orientation of the TCP changes continuously during the motion, but not uniformly. This is done by linear transformation (axis-specific motion) of the wrist axis angles. Note: This orientation type is not suitable if a specific orientation must be maintained exactly. |