IDN 3003 (P-0-3003) Configurable I/O: Digital Input 4 Mode
Determines the functionality of digital inputs 1 through 4.
The digital inputs may be read directly through IDN 3030 through IDN 3033 .
The following table describes the functions that are available.
A new input mode will not be active until the parameter set is saved to non-volatile memory and a cold start or warm start ( IDN 128 procedure is initiated.
Data Length:  | 2 bytes  | Non-Volatile:  | Yes  | 
Data Type:  | Unsigned decimal  | Write Access:  | CP2, CP3  | 
Minimum:  | 
  | Run-Up Check:  | 
  | 
Maximum:  | 
  | Cyclic Transfer:  | 
  | 
Default:  | 
  | Serial Equiv:  | InxMODE (x = 1, 2, 3, or 4).  | 
Units:  | 
  | Version:  | |
IDN Type:  | IO  | ADS Index Group (hex.):  | 0x8BBB  | 
Definition:
INx-Mode  | Description  | Active Edge  | Digital Input  | ||||
|---|---|---|---|---|---|---|---|
1  | 2  | 3  | 4  | ||||
0  | Reserved  | –  | 
  | 
  | 
  | 
  | |
1  | Reset  | 
  | x  | 
  | 
  | 
  | |
2  | PSTOP  | Active low  | 
  | 
  | x  | x  | |
3  | NSTOP  | Active low  | 
  | 
  | x  | x  | |
4  | PSTOP+Intg.Off  | Active low  | 
  | 
  | x  | 
  | |
5  | NSTOP+Intg.Off  | Active low  | 
  | 
  | 
  | x  | |
6  | PSTOP+NSTOP  | Active low  | 
  | 
  | x  | 
  | |
7  | P/NSTOP+Intg.Off  | Active low  | 
  | 
  | x  | 
  | |
8  | SETP.1/SETP.2  | 
  | x  | x  | x  | x  | |
9  | MT_No_Bit  | 
  | x  | x  | x  | x  | |
10  | Intg.Off  | Rising  | x  | x  | x  | x  | |
11  | v/Torq.Contr.  | Active high  | x  | x  | x  | x  | |
12  | Reference  | x  | x  | x  | x  | ||
13  | ROD/SSI  | Low/High  | x  | x  | x  | x  | |
14  | FError_clear  | 
  | x  | x  | x  | x  | |
15  | Start_MT Next  | 
  | x  | x  | x  | x  | |
16  | Start_MT No x  | 
  | x  | x  | x  | x  | |
17  | Start_ MT IO  | 
  | x  | x  | x  | x  | |
18  | Ipeak2x  | 
  | x  | x  | x  | x  | |
19  | Reserved  | 
  | 
  | 
  | 
  | 
  | |
20  | Start_Jog v=x  | 
  | x  | x  | x  | x  | |
21  | U_Mon.off  | High  | x  | x  | x  | x  | |
22  | MT Restart  | 
  | x  | x  | x  | x  | |
23  | Start2_MT No x  | 
  | x  | x  | x  | x  | |
24  | Switch over OPMODE  | 
  | x  | x  | x  | x  | |
25  | Zero_latch  | 
  | x  | x  | x  | x  | |
26  | Position Latch  | x  | x  | 
  | 
  | ||
27  | Emergency Stop  | 
  | x  | x  | x  | x  | |
28  | Reserved  | 
  | 
  | 
  | 
  | 
  | |
29  | Reserved  | 
  | 
  | 
  | 
  | 
  | |
30  | Command Buffer 1  | 
  | x  | x  | x  | x  | |
31  | Command Buffer 2  | 
  | x  | x  | x  | x  | |
32  | Brake  | 
  | x  | x  | x  | x  | |
33  | see 30  | 
  | x  | x  | x  | x  | |
34  | see 31  | 
  | x  | x  | x  | x  | |
35  | Select Velocity/Current Entry  | 
  | x  | x  | x  | x  | |
36  | Give Offset to Gearing Function  | 
  | x  | x  | x  | x  | |
37  | Change source of actual position at EXTPOS=1  | 
  | x  | x  | x  | x  | |
38  | Enable signal for following motion task  | 
  | x  | 
  | 
  | 
  | |
39  | Constant Speed for defined time  | 
  | x  | x  | x  | x  | |
40  | Additional hardware input (enable)  | 
  | x  | x  | x  | x  | |
41  | Fast emergency stop  | 
  | x  | x  | x  | x  | |