IDN 179 (S-0-0179) Probe Position Latch Status

The probe status parameter indicates whether a position has been captured and latched within one of the „Probe Edge Value“ IDNs ( IDN 130 0 through 133). IDN 179 duplicates the information found in IDN 409 9 through 412.

Data Length:

2 bytes

Non-Volatile:

No

Data Type:

Binary

Write Access:

Read-only

Minimum:

 

Run-Up Check:

 

Maximum:

 

Cyclic Transfer:

 

Default:

0

Serial Equiv:

 

Units:

 

Version:

5.04 

IDN Type:

PS

ADS Index Group (hex.):

0x00B3

Definition:

Bit

Description

Setting

LSB 0

Probe 1 – Position latched on positive edge ( IDN 130 )

0 = No.

1 = Latched.

1

Probe 1 – Position latched on negative edge ( IDN 131 )

0 = No.

1 = Latched.

2

Probe 2 – Position latched on positive edge ( IDN 132 )

0 = No.

1 = Latched.

3

Probe 2 – Position latched on negative edge ( IDN 133 )

0 = No.

1 = Latched.

4 - 15

Reserved.

Set to 0.