General
The General tab provides an overview of the camera object in TwinCAT and the connected camera.

General object information
The upper part contains general information about the camera object:

Name | Selected name of the object. Do not assign an object name more than once! |
Object Id | 32-bit identification number that is automatically assigned and unique within a project. |
Type | Object type. |
Comment | Freely editable field for user notes. |
Id | Identification number of the camera modules, which is assigned consecutively. If a camera module is deleted, the number becomes free again and can be assigned to a new camera module. |
Status of the camera instance
The middle part contains status information for the camera instance:

The following table explains the individual elements:
Connection | Displays the connection status to the camera. Via the button Possible status:
|
GenApi Descr. | This indicates whether the GenApi structure (feature tree in the Configuration Assistant) was successfully created. Status options:
The button
|
Param. Values | Status options:
The button
|
Simulation Mode | In simulation mode, images from recorded camera streams can be sent to the PLC instead of a real camera supplying images (see Record/Playback). If the simulation mode is activated, the Image Acquisition Object is automatically deactivated and the Image Acquisition Simulation Object is activated. If the simulation mode is deactivated, the Image Acquisition Object is automatically activated and the Image Acquisition Simulation Object is deactivated. The corresponding object links (see Camera details) will each be adjusted automatically. Default: disabled. |
ADS Communication Module | Required for the recording of a camera stream, see Record/Playback. This checkbox merely activates or deactivates the Ads Communicator object of the Camera object. Please note that if Ads Communicator object is activated, images captured by the camera will still be internally referenced for a short while so that they cannot be transformed into displayable images. Default: disabled. |
Clear Messages | Use this button to delete the messages written by this camera object. The button is only active if messages are present. |
Camera information
In the lower part, general camera information is displayed as far as it could be read from the camera (e.g. manufacturer and model name of the camera). This information can also be found in the configuration tree.

the display can be updated with Refresh Camera Status. In addition, it is possible to open the dialog for selecting a camera with Choose Target Camera
also allows the following actions: