Error messages of the real-time driver of mxAutomation
|
No. |
Message text |
Cause |
Remedy |
|---|---|---|---|
|
701 |
INTERNAL ERROR |
Internal exceptional error |
Contact KUKA Deutschland GmbH. (>>> KUKA Service) |
|
702 |
ASSERT FAILED |
Internal exceptional error | |
|
703 |
INVALID COMMAND ID |
Internal exceptional error | |
|
704 |
INVALID HEADER DATA |
Internal exceptional error | |
|
709 |
ERROR READING SOFTPLC |
Internal exceptional error | |
|
710 |
ERROR FROM KRC SUBMIT |
Internal exceptional error | |
|
712 |
INVALID CHECKSUM PLC -> KRC |
The checksum for data transmission from the PLC to the robot controller is invalid. |
Contact KUKA Deutschland GmbH. (>>> KUKA Service) |
|
713 |
INVALID MOVE TYPE |
An invalid value has been programmed in a KRC_Move function block for the parameter MoveType. |
Contact KUKA Deutschland GmbH. (>>> KUKA Service) |
|
730 |
INVALID PTP APO |
An invalid approximation parameter has been transferred for a PTP motion. |
Program a valid value (Approximate parameter). (>>> APO) |
|
731 |
INVALID CP APO |
An invalid approximation parameter has been transferred for a CP motion (LIN, CIRC). | |
|
732 |
INVALID BASE NUMBER |
An invalid number has been programmed for the BASE coordinate system in the KRC_ReadBaseData or KRC_WriteBaseData function block. |
Specify the number of the BASE coordinate system that is currently being used in the robot controller (BaseNo parameter).
|
|
An invalid number has been programmed for the BASE coordinate system in a KRC_Move or KRC_Jog function block. |
Specify the number of the BASE coordinate system that is currently being used in the robot controller (CoordinateSystem – COORDSYS.Base parameter). (>>> COORDSYS) | ||
|
733 |
INVALID TOOL NUMBER |
An invalid number has been programmed for the TOOL coordinate system in the KRC_ReadToolData or KRC_WriteToolData function block. |
Specify the number of the TOOL coordinate system that is currently being used in the robot controller (ToolNo parameter).
|
|
An invalid number has been programmed for the TOOL coordinate system in a KRC_Move or KRC_Jog function block. |
Specify the number of the TOOL coordinate system that is currently being used in the robot controller (CoordinateSystem – COORDSYS.Tool parameter). (>>> COORDSYS) | ||
|
734 |
INVALID VELOCITY |
An invalid value has been programmed for the speed in a function block. |
Program a valid value (Velocity parameter):
|
|
735 |
INVALID ACCELERATION |
An invalid value has been programmed for the acceleration in a function block. |
Program a valid value (Acceleration parameter):
|
|
736 |
INVALID C_PTP |
An invalid approximation distance has been transferred for a PTP motion. |
Program a valid value (Approximate parameter). (>>> APO) |
|
737 |
INVALID C_DIS |
An invalid distance parameter has been transferred for an approximate positioning motion. | |
|
738 |
INVALID C_VEL |
An invalid speed parameter has been transferred for an approximate positioning motion. | |
|
739 |
INVALID C_ORI |
An invalid alignment parameter has been transferred for an approximate positioning motion. | |
|
740 |
INVALID ORI_TYPE |
An invalid value has been programmed in a KRC_Move or KRC_Jog function block for the alignment control of the TCP. |
Program a valid value (OriType parameter). (>>> OriType) |
|
741 |
POSITION DATA NOT INITIALIZED |
No target position transferred when calling a KRC_Move function block. |
Define at least 1 element of the target position (Position parameter). (>>> E6POS) |
|
742 |
AXISPOSITION DATA NOT INITIALIZED |
No axis position transferred when calling a KRC_MoveAxis function block. |
Define at least 1 axis position (AxisPosition parameter). (>>> E6AXIS) |
|
743 |
INVALID TRIGGER DISTANCE |
An invalid value has been programmed for the switching point of the switch in a KRC_SetDistanceTrigger function block. |
Program a valid value (Distance parameter):
|
|
744 |
INVALID TRIGGER IO |
An invalid output has been programmed in a KRC_SetDistanceTrigger or KRC_SetPathTrigger function block. |
Program a valid value (Output parameter):
|
|
745 |
INVALID TRIGGER PULSE |
An invalid value has been programmed in a KRC_SetDistanceTrigger or KRC_SetPathTrigger function block for the pulse length. |
Program a valid value (Pulse parameter):
|
|
746 |
INVALID CIRC_HP |
No auxiliary position transferred when calling a KRC_MoveCirc function block. |
Define at least 1 element of the auxiliary position (CircHP parameter). (>>> E6AXIS) |
|
747 |
INVALID INTERRUPT IO |
The number of the digital input for which the interrupt is declared is invalid (KRC_DeclareInterrupt function block). |
Program a valid value (Input parameter):
|
|
748 |
INVALID INTERRUPT PRIORITY |
An invalid number was transferred when calling a KRC_…Interrupt function block. |
Program a valid value (Interrupt parameter):
|
|
750 |
INVALID INTERRUPT ACTION |
The interrupt reaction programmed during the declaration of the interrupt is invalid. |
Program a valid reaction (Reaction parameter). (>>> Declaring interrupts) |
|
751 |
INVALID IO NUMBER |
The number of the digital input for which the interrupt is declared is invalid (KRC_DeclareInterrupt function block). |
Program a valid value (Input parameter):
|
|
752 |
INVALID PULSE DURATION |
An invalid value has been programmed for the pulse length in the KRC_WriteDigitalOutput function block. |
Program a valid value (Pulse parameter):
|
|
753 |
INVALID BUFFER_MODE |
An invalid BufferMode has been programmed in a function block, e.g. DIRECT mode is not available for certain function blocks. |
Program a valid BufferMode. (>>> BufferMode) |
|
754 |
INVALID TOOL NUMBER FOR LOAD_DATA |
An invalid number has been programmed in the KRC_ReadLoadData or KRC_WriteLoadData function block for reading or writing the load data or supplementary load data. |
Program a valid value (Tool parameter). (>>> Reading the load data) (>>> Writing load data) |
|
755 |
INVALID ANALOG IO NUMBER |
An invalid value has been programmed in a function block for the analog input or output. |
Program a valid value (Number parameter):
|
|
756 |
INVALID IPO_MODE |
An invalid value has been programmed in a function block for the interpolation type, e.g. KRC_Move. |
Program a valid value (CoordinateSystem – COORDSYS.IPO_MODE parameter). (>>> COORDSYS) |
|
757 |
INVALID CIRC_TYPE |
An invalid value has been programmed in a KRC_MoveCirc function block for the alignment control during the circular motion. |
Program a valid value (CircType parameter). (>>> CircType) |
|
758 |
INVALID FRAME DATA |
Invalid TOOL or BASE data have been programmed in a KRC_WriteToolData or KRC_WriteBaseData function block. |
Program valid data (parameter ToolData or BaseData). (>>> Writing TOOL data) (>>> Writing BASE data) |
|
759 |
INVALID LOAD DATA |
Invalid load data have been programmed in a KRC_WriteLoadData function block. |
Program valid data. (>>> Writing load data) |
|
760 |
INVALID SOFT_END (REVERSED) |
Error when writing the software limit switches: positive software limit switch < negative software limit switch (KRC_WriteSoftEnd or KRC_WriteSoftEndEx function block) |
Program lower values for the negative software limit switch than for the positive software limit switch. |
|
765 |
INVALID REAL VALUE |
The programmed Real value is invalid. |
|
|
770 |
INVALID PARAMETER VALUE |
An invalid value has been programmed in the called function block for one or more parameters. |
Program valid values for the parameters. |
|
771 |
INVALID ADVANCE COUNT |
In the KRC_SetAdvance function block, an invalid value has been programmed for the number of functions that are to be transferred prior to the first robot motion. |
Program a valid value (Count parameter):
|
|
772 |
INVALID MAXWAITTIME |
In the KRC_SetAdvance function block, an invalid value has been programmed for the maximum delay time before the start of the program execution if the specified number of functions in the Count parameter is not reached. |
Program a valid value (MaxWaitTime parameter):
|
|
773 |
INVALID ADVANCE MODE |
In the KRC_SetAdvance function block, an invalid value has been programmed for wait mode. |
Program a valid value (Mode parameter):
|
|
774 |
INVALID DI STARTNUMBER |
In the KRC_ReadDigitalInputArray function block, an invalid value has been programmed for the number of the first digital input that is called. |
Program a valid value (Startnumber parameter):
|
|
775 |
INVALID DI LENGTH |
In the function block KRC_ReadDigitalInputArray, an invalid value has been programmed for the number of inputs that are polled. |
Program a valid value (Length parameter):
|
|
780 |
INVALID WORKSPACENO |
In the called function block, an invalid number has been programmed for the number of the workspace. |
Program a valid value (WorkspaceNo parameter):
|
|
781 |
INVALID WORKSPACEMODE |
In the called function block, an invalid number has been programmed for the mode for workspaces. |
Program a valid value (WorkspaceMode parameter):
|
|
782 |
INVALID WORKSPACEPART |
Internal exceptional error |
Contact KUKA Deutschland GmbH. (>>> KUKA Service) |
|
783 |
UDP CONNECTION TIMEOUT |
Connection timeout during UDP communication |
Check the IP addresses of the two connection points and the cable between them. Define a longer value for the timeout in the mxa_config.dat file. |
|
801 |
STOPMESS ACTIVE |
Group error that prevents motion enable |
Check how the error was triggered and correct the error.
|