Supported SNVTs
General information about SNVTs can be found on the internet under www.lonmark.org.
The KL6401 supports the following SNVTs (LonMark data types).
SNVT ID | SNVT NAME | Read | Send | Additional information |
|---|---|---|---|---|
1 | SNVT_amp |
| ||
2 | SNVT_amp_mil |
| ||
3 | SNVT_angle |
| ||
4 | SNVT_angle_vel |
| ||
5 | SNVT_btu_kilo |
| ||
6 | SNVT_btu_mega |
| ||
7 | SNVT_char_ascii |
| ||
8 | SNVT_count |
| ||
9 | SNVT_count_inc |
| ||
10 | SNVT_date_cal |
|
| SNVT obsolete, not implemented |
11 | SNVT_date_day |
| ||
12 | SNVT_date_time |
|
| SNVT obsolete, not implemented |
13 | SNVT_elec_kwh |
| ||
14 | SNVT_elec_whr |
| ||
15 | SNVT_flow |
| ||
16 | SNVT_flow_mil |
| ||
17 | SNVT_length |
| ||
18 | SNVT_length_kilo |
| ||
19 | SNVT_length_micr |
| ||
20 | SNVT_length_mil |
| ||
21 | SNVT_lev_cont |
| ||
22 | SNVT_lev_disc |
|
| SNVT obsolete, not implemented |
23 | SNVT_mass |
| ||
24 | SNVT_mass_kilo |
| ||
25 | SNVT_mass_mega |
| ||
26 | SNVT_mass_mil |
| ||
27 | SNVT_power |
| ||
28 | SNVT_power_kilo |
| ||
29 | SNVT_ppm |
| ||
30 | SNVT_press |
| ||
31 | SNVT_res |
| ||
32 | SNVT_res_kilo |
| ||
33 | SNVT_sound_db |
| ||
34 | SNVT_speed |
| ||
35 | SNVT_speed_mil |
| ||
36 | SNVT_str_asc |
| ||
37 | SNVT_str_int |
| ||
38 | SNVT_telcom |
| ||
39 | SNVT_temp |
| ||
40 | SNVT_time_passed |
|
| SNVT obsolete, not implemented |
41 | SNVT_vol |
| ||
42 | SNVT_vol_kilo |
| ||
43 | SNVT_vol_mil |
| ||
44 | SNVT_volt |
| ||
45 | SNVT_volt_dbmv |
| ||
46 | SNVT_volt_kilo |
| ||
47 | SNVT_volt_mil |
| ||
48 | SNVT_amp_f |
| ||
49 | SNVT_angle_f |
| ||
50 | SNVT_angle_vel_f |
| ||
51 | SNVT_count_f |
| ||
52 | SNVT_count_inc_f |
| ||
53 | SNVT_flow_f |
| ||
54 | SNVT_length_f |
| ||
55 | SNVT_lev_cont_f |
| ||
56 | SNVT_mass_f |
| ||
57 | SNVT_power_f |
| ||
58 | SNVT_ppm_f |
| ||
59 | SNVT_press_f |
| ||
60 | SNVT_res_f |
| ||
61 | SNVT_sound_db_f |
| ||
62 | SNVT_speed_f |
| ||
63 | SNVT_temp_f |
| ||
64 | SNVT_time_f |
| ||
65 | SNVT_vol_f |
| ||
66 | SNVT_volt_f |
| ||
67 | SNVT_btu_f |
| ||
68 | SNVT_elec_whr_f |
| ||
69 | SNVT_config_src |
| ||
70 | SNVT_color |
| ||
71 | SNVT_grammage |
| ||
72 | SNVT_grammage_f |
| ||
73 | SNVT_file_req | Under construction, please not use. | ||
74 | SNVT_file_status |
| ||
75 | SNVT_freq_f |
| ||
76 | SNVT_freq_hz |
| ||
77 | SNVT_freq_kilohz |
| ||
78 | SNVT_freq_milhz |
| ||
79 | SNVT_lux |
| ||
80 | SNVT_ISO_7811 |
|
| SNVT obsolete, not implemented |
81 | SNVT_lev_percent |
| ||
82 | SNVT_multiplier |
| ||
83 | SNVT_state |
| ||
84 | SNVT_time_stamp |
| ||
85 | SNVT_zerospan |
| ||
86 | SNVT_magcard |
| ||
87 | SNVT_elapsed_tm |
| ||
88 | SNVT_alarm |
| ||
89 | SNVT_currency |
| ||
90 | SNVT_file_pos |
| ||
91 | SNVT_muldiv |
| ||
92 | SNVT_obj_request |
| ||
93 | SNVT_obj_status |
| ||
94 | SNVT_preset |
| ||
95 | SNVT_switch |
| ||
96 | SNVT_trans_table |
| ||
97 | SNVT_override |
| ||
98 | SNVT_pwr_fact |
| ||
99 | SNVT_pwr_fact_f |
| ||
100 | SNVT_density |
| ||
101 | SNVT_density_f |
| ||
102 | SNVT_rpm |
| ||
103 | SNVT_hvac_emerg |
| ||
104 | SNVT_angle_deg |
| ||
105 | SNVT_temp_p |
| ||
106 | SNVT_temp_setpt |
| ||
107 | SNVT_time_sec |
| ||
108 | SNVT_hvac_mode |
| ||
109 | SNVT_occupancy |
| ||
110 | SNVT_area |
| ||
111 | SNVT_hvac_overid |
| ||
112 | SNVT_hvac_status |
| ||
113 | SNVT_press_p |
| ||
114 | SNVT_address |
| ||
115 | SNVT_scene |
| ||
116 | SNVT_scene_cfg |
| ||
117 | SNVT_setting |
| ||
118 | SNVT_evap_state |
| ||
119 | SNVT_therm_mode |
| ||
120 | SNVT_defr_mode |
| ||
121 | SNVT_defr_term |
| ||
122 | SNVT_defr_state |
| ||
123 | SNVT_time_min |
| ||
124 | SNVT_time_hour |
| ||
125 | SNVT_ph |
| ||
126 | SNVT_ph_f |
| ||
127 | SNVT_chlr_status |
| ||
128 | SNVT_tod_event |
| ||
129 | SNVT_smo_obscur |
| ||
130 | SNVT_fire_test |
| ||
131 | SNVT_temp_ror |
| ||
132 | SNVT_fire_init |
| ||
133 | SNVT_fire_indcte |
| ||
134 | SNVT_time_zone |
| ||
135 | SNVT_earth_pos |
| ||
136 | SNVT_reg_val |
| ||
137 | SNVT_reg_val_ts |
| ||
138 | SNVT_volt_ac |
| ||
139 | SNVT_amp_ac |
| ||
|
|
|
|
|
143 | SNVT_turbidity |
| ||
144 | SNVT_turbidity_f |
| ||
145 | SNVT_hvac_type |
| ||
146 | SNVT_elec_kwh_l |
| ||
147 | SNVT_temp_diff_p |
| ||
148 | SNVT_ctrl_req |
| ||
149 | SNVT_ctrl_resp |
| ||
150 | SNVT_ptz |
| ||
151 | SNVT_privacyzone |
| ||
152 | SNVT_pos_ctrl |
| ||
153 | SNVT_enthalpy |
| ||
154 | SNVT_gfci_status |
| ||
155 | SNVT_motor_state |
| ||
156 | SNVT_pumpset_mn |
| ||
157 | SNVT_ex_control |
| ||
158 | SNVT_pumpset_sn |
| ||
159 | SNVT_pump_sensor |
| ||
160 | SNVT_abs_humid |
| ||
161 | SNVT_flow_p |
| ||
162 | SNVT_dev_c_mode |
| ||
163 | SNVT_valve_mode |
| ||
164 | SNVT_alarm_2 |
| ||
165 | SNVT_state_64 |
| ||
166 | SNVT_nv_type |
| ||
|
|
|
|
|
168 | SNVT_ent_opmode |
| ||
169 | SNVT_ent_state |
| ||
170 | SNVT_ent_status |
| ||
171 | SNVT_flow_dir |
| ||
172 | SNVT_hvac_satsts |
| ||
173 | SNVT_dev_status |
| ||
174 | SNVT_dev_fault |
| ||
175 | SNVT_dev_maint |
| ||
176 | SNVT_date_event |
| ||
177 | SNVT_sched_val |
| ||
178 | SNVT_sec_state |
|
| SNVT obsolete, not implemented |
179 | SNVT_sec_status |
|
| SNVT obsolete, not implemented |
180 | SNVT_sblnd_state |
| ||
181 | SNVT_rac_ctrl |
| ||
182 | SNVT_rac_req |
| ||
183 | SNVT_count_32 |
| ||
184 | SNVT_clothes_w_c |
| ||
185 | SNVT_clothes_w_m |
| ||
186 | SNVT_clothes_w_s |
| ||
187 | SNVT_clothes_w_a |
| ||
188 | SNVT_multiplier_s |
| ||
189 | SNVT_switch_2 |
| ||
190 | SNVT_color_2 |
| ||
191 | SNVT_log_status |
| ||
192 | SNVT_time_stamp_p |
| ||
193 | SNVT_log_fx_request |
| ||
194 | SNVT_log_fx_status |
| ||
195 | SNVT_log_request |
| ||
196 | SNVT_enthalpy_d |
| ||
197 | SNVT_amp_ac_mil |
| ||
198 | SNVT_time_hour_p |
| ||
199 | SNVT_lamp_status |
| ||
200 | SNVT_environment |
| ||
201 | SNVT_geo_loc |
|