POUs
|
Function blocks |
Description |
|---|---|
|
Send / receive function block |
Read
|
POUs |
Description |
|---|---|
|
Electric current (Amperes) | |
|
Electric current (milliAmperes) | |
|
Angular distance (radians) | |
|
Angular velocity (radians/second) | |
|
Thermal energy (kilo-Btus) | |
|
Thermal energy (mega-Btus) | |
|
ASCII character (8-bit ASCII character) | |
|
Absolute count (units) | |
|
Increment count (units (delta)) | |
|
Day of week (day names) | |
|
Electric energy (kiloWatt-hours) | |
|
Electric energy (Watt-hours) | |
|
Flow volume (liters/second) | |
|
Flow volume (milliliters/second) | |
|
Length (meters) | |
|
Length (kilometers) | |
|
Length(micrometers (microns)) | |
|
Length (millimeters) | |
|
Continuous level (% of full level) | |
|
Mass (grams) | |
|
Mass (kilograms) | |
|
Mass (metric tons) | |
|
Mass (milligrams) | |
|
Power (Watts) | |
|
Power (kiloWatts) | |
|
Concentration (ppm) | |
|
Pressure (gauge) (kiloPascals) | |
|
Electric resistance (Ohms) | |
|
Electric resistance (kiloOhms) | |
|
Sound level (dB) | |
|
Linear velocity (meters/second) | |
|
Linear velocity (meters/second) | |
|
Character string | |
|
Wide character string with locale code | |
|
Telecomm states | |
|
Temperature (degrees Celsius) | |
|
Volume (liters) | |
|
Volume (kiloliters) | |
|
Volume (milliliters) | |
|
Electric voltage (Volts) | |
|
Electric voltage (dB microVolts) | |
|
Electric voltage (kiloVolts) | |
|
Electric voltage (milliVolts) | |
|
Electric current (Amperes) | |
|
Angular distance (radians) | |
|
Angular velocity (radians/second) | |
|
Absolute count (units) | |
|
Increment count (units (delta)) | |
|
Flow volume (liters/second) | |
|
Length (meters) | |
|
Continuous level | |
|
Mass (grams) | |
|
Power (Watts) | |
|
Concentration (ppm) | |
|
Pressure (gauge) (Pascals) | |
|
Electric resistance (Ohms) | |
|
Sound level (dBspl) | |
|
Linear velocity (meters/second) | |
|
Temperature (degrees Celsius) | |
|
Elapsed time (seconds) | |
|
Volume (liters) | |
|
Electric voltage (Volts) | |
|
Thermal energy (Btus) | |
|
Electric energy (Watt-hours) | |
|
Configuration source | |
|
CIELAB color (L*,a*,b) | |
|
Grammage (grams/sq meter) | |
|
Grammage (grams/sq meter) | |
|
File request | |
|
File status | |
|
Frequency (Hertz) | |
|
Frequency (Hertz) | |
|
Frequency (kiloHertz) | |
|
Frequency (Hertz) | |
|
Illumination (lux) | |
|
Percentage level (% of full level) | |
|
Multiplier | |
|
State vector | |
|
Time stamp | |
|
Zero and span | |
|
ISO 7811 (40 hexadecimal digits) | |
|
Elapsed time | |
|
Alarm status | |
|
Currency | |
|
File position | |
|
Multiply/Divide | |
|
Object request | |
|
Object status | |
|
Preset | |
|
Switch | |
|
Translation table | |
|
Override code | |
|
Power factor | |
|
Power factor (multiplier) | |
|
Density (kilograms/cubic meter) | |
|
Density (kilograms/cubic meter) | |
|
Angular velocity (revolutions/minute (RPM)) | |
|
HVAC emergency mode | |
|
Angular distance(degrees) | |
|
Temperature (degrees Celsius) | |
|
Temperature | |
|
Elapsed time (seconds) | |
|
HVAC mode | |
|
Occupancy | |
|
Area (square meters) | |
|
HVAC override | |
|
HVAC status | |
|
Pressure | |
|
Neuron address | |
|
Scene control | |
|
Scene configuration | |
|
Setting control | |
|
Evaporator state | |
|
Thermostat mode | |
|
Defrost mode | |
|
Defrost termination | |
|
Defrost state | |
|
Elapsed time | |
|
Elapsed time | |
|
Acidity (pH) | |
|
Acidity (pH) | |
|
Chiller status | |
|
Time of day event | |
|
Smoke obscuration | |
|
Fire test request | |
|
Temperature rate of change/rise | |
|
Fire initiator type | |
|
Fire indicator type | |
|
Time zone descriptor | |
|
Earth position | |
|
Register value | |
|
Register value | |
|
Voltage in alternating current | |
|
Amperage in alternating current | |
|
Turbidity | |
|
Turbidity | |
|
HVAC unit type | |
|
Electric energy | |
|
Temp difference | |
|
Control request | |
|
Control response | |
|
Camera PTZ | |
|
Privacy zone | |
|
Position control | |
|
Enthalpy (kiloJoules/kg) | |
|
GFCI status type | |
|
Motor state | |
|
Pumpset | |
|
Exclusive control | |
|
Pumpset sensor | |
|
Pump sensor | |
|
Absolute humidity | |
|
Flow volume | |
|
Device control mode | |
|
Valve mode | |
|
Alarm status 2 | |
|
State vector | |
|
Network variable type | |
|
Entry operation mode | |
|
Entry state | |
|
Entry status | |
|
Flow direction | |
|
HVAC saturation status | |
|
Device status | |
|
Device fault states | |
|
Device maintenance | |
|
Date event | |
|
Scheduler value | |
|
Sunblind State | |
|
Rail-Audio Controller Control | |
|
Rail-Audio Controller Request | |
|
Absolute count | |
|
Clothes Washer Command | |
|
Clothes Washer-Management Status | |
|
Clothes Washer Status | |
|
Clothes Washer Alarm | |
|
Value multiplier | |
|
Switch with scene and setting control. | |
|
Color. | |
|
Log status (hundredths of second) | |
|
Precision timestamp. | |
|
Log file transfer request. | |
|
Log file transfer status. | |
|
Log status request. | |
|
Enthalpy difference (kJ/kg) . | |
|
Electrical current (milliAmperes) . | |
|
Time hour (hours) . | |
|
Lamp Status. | |
|
Environment. | |
|
Geographic Location. |
Send
|
Function blocks |
Description |
|---|---|
|
Electric current (ampere) | |
|
Electric current (milliampere) | |
|
Angular distance (radian) | |
|
Angular velocity (radian / second) | |
|
Thermal energy (kiloBtu) | |
|
Thermal energy (megaBtu) | |
|
ASCII character (8-bit ASCII character) | |
|
Absolute number (items) | |
|
Increment counter (items(delta)) | |
|
Day of the week | |
|
Electric energy (kW / hour) | |
|
Electric energy (Watt / hour) | |
|
Volume flow (liters / second) | |
|
Volume flow (milliliters / second) | |
|
Length (meter) | |
|
Length (kilometer) | |
|
Length (micrometer) | |
|
Length (millimeter) | |
|
Continuous change in value (% from maximum level) | |
|
Mass (gram) | |
|
Mass (kilogram) | |
|
Mass (metric ton) | |
|
Mass (milligram) | |
|
Power (watt) | |
|
Power (kilowatt) | |
|
Concentration (ppm) | |
|
Pressure (overpressure) (kilopascal) | |
|
Electric resistance (ohm) | |
|
Electric resistance (kiloohm) | |
|
Sound pressure level (dB) | |
|
Linear velocity (meters / second) | |
|
Linear velocity (meters / second) | |
|
String (max. 30 characters) (ASCII string) | |
|
Wide Character String | |
|
Telephone status (telephone status name) | |
|
Temperature (°C) | |
|
Volume (liter) | |
|
Volume (kiloliter) | |
|
Volume (milliliter) | |
|
Electrical voltage (volt) | |
|
Electrical voltage (dB microvolt) | |
|
Electrical voltage (kilovolt) | |
|
Electrical voltage (millivolt) | |
|
Electric current (ampere) | |
|
Angular distance (radian) | |
|
Angular velocity (radian / second) | |
|
Absolute number (items) | |
|
Increment counter (items(delta)) | |
|
Volume flow (liters / second) | |
|
Length (meter) | |
|
Continuous change in value (% from maximum level) | |
|
Mass (gram) | |
|
Power (watt) | |
|
Concentration (ppm) | |
|
Pressure (overpressure) (pascal) | |
|
Electric resistance (ohm) | |
|
Sound pressure level (dBspl) | |
|
Linear velocity (meters / second) | |
|
Temperature (°C) | |
|
Elapsed time (seconds) | |
|
Volume (liter) | |
|
Electrical voltage (volt) | |
|
Thermal energy (Btu) | |
|
Electric energy (Watt / hour) | |
|
Configuration properties | |
|
Color according to CIE standard | |
|
American measure for paper weight and density | |
|
American measure for paper weight and density | |
|
File request | |
|
File information | |
|
Frequency (hertz) | |
|
Frequency (hertz) | |
|
Frequency (kilohertz) | |
|
Frequency (millihertz) | |
|
Illuminance (lux) | |
|
Percentage value | |
|
Multiplier | |
|
Status information | |
|
Time stamp | |
|
Zero point and proportionality factor | |
|
ISO 7811 (40 hexadecimal numbers) | |
|
Elapsed time | |
|
Alarm status | |
|
Currency | |
|
File position | |
|
Gain factor/attenuation factor | |
|
Function selection | |
|
Object status | |
|
Preliminary setting | |
|
Switch | |
|
Conversion table | |
|
Override mode | |
|
Power factor | |
|
Power factor | |
|
Density (kg/m³) | |
|
Density (kg/m³) | |
|
Angular velocity (revolutions/minute (RPM)) | |
|
HVAC emergency mode | |
|
Angle indication | |
|
Temperature (°C) | |
|
Temperature (6 temperature values) | |
|
Elapsed time (second) | |
|
HVAC operating mode | |
|
Occupancy signal (states) | |
|
Area (square meter) | |
|
HVAC override mode | |
|
HVAC status | |
|
Pressure (overpressure) (pascal) | |
|
Neuron address (16-bit address value) | |
|
Scenes | |
|
Scene setting | |
|
Settings | |
|
Evaporator status | |
|
Thermostat mode | |
|
Defrost mode | |
|
Completion of the defrost cycle | |
|
Defrost status (enumeration) | |
|
Elapsed time (minutes) | |
|
Elapsed time (hour) | |
|
Acidity (pH) | |
|
Acidity (pH) | |
|
Refrigeration unit status | |
|
Presence time | |
|
Darkening due to smoke | |
|
Request fire alarm system test | |
|
Value of the temperature change/increase | |
|
Fire detector type | |
|
Fire alarm display | |
|
Time zone description | |
|
Position on Earth | |
|
Register value | |
|
Register value | |
|
Alternating voltage | |
|
Alternating current | |
|
Turbidity | |
|
Turbidity | |
|
HVAC plant type | |
|
Electric energy (kW / hour) | |
|
Temperature difference (°C) | |
|
Control request | |
|
Control response | |
|
Camera PTZ (SNZ) | |
|
Private zone | |
|
Position setting for cameras in networks | |
|
Enthalpy (kilojoules/kg) | |
|
Residual current circuit breaker status | |
|
Motor status (motor status designation) | |
|
Pump group | |
|
Exclusive control | |
|
Pump group sensor | |
|
Pump sensor (speed, temperature, status) | |
|
Absolute humidity | |
|
Volume flow (cubic meters / hour) | |
|
Device operating mode | |
|
Valve state | |
|
Alarm status 2 | |
|
Status information (64 individual bit values) | |
|
Network variable type | |
|
Operating mode for access objects | |
|
State for access objects | |
|
Status of access objects | |
|
Flow direction | |
|
HVAC saturation status | |
|
Device status | |
|
Error state | |
|
Device maintenance status | |
|
Event status | |
|
Calendar value | |
|
Blind status | |
|
Sound function control | |
|
Sound function request | |
|
Absolute counter | |
|
Washing machine / commands | |
|
Washing machine /management status | |
|
Washing machine / status | |
|
Washing machine / status | |
|
Multiplier | |
|
Switch for setting scenes and settings. | |
|
Color | |
|
Log status | |
|
Precise time stamp | |
|
Log file transfer request | |
|
Log file transfer status. | |
|
Log status request | |
|
Enthalpy difference (kJ/kg) | |
|
Electric current (milliampere) | |
|
Time in hours | |
|
Lamp status | |
|
Environment | |
|
Geographical location |