IDN 45 (S-0-0045) Velocity Data Scaling Factor
The scaling factor for all velocity data in the drive. The exponent is defined with IDN 46 , so that the LSB weight of all rotational velocity data is derived from the following equation:
The scaling may be defined within the following range: 1x10-5 to 1x100. IDN 45 and IDN 46 must be integers. If preferred rotational scaling is selected in IDN 44 , the velocity scaling factor (IDN 45) and the velocity data scaling exponent ( IDN 46 ) will fixed set to their default values (refer to IDN 44 ). By the velocity scaling it is possible to get a rounding error in the LSBits.

Data Length: | 2 bytes | Non-Volatile: | No |
Data Type: | Unsigned decimal | Write Access: | CP2, CP3 |
Minimum: | 1 | Run-Up Check: |
|
Maximum: | 10-( IDN 46 ) | Cyclic Transfer: |
|
Default: | 1 | Serial Equiv: |
|
Units: |
| Version: | |
IDN Type: | VE | ADS Index Group (hex.): | 0x002D |