Industrie-PC

Feldbuskomponenten

Antriebstechnik


Servoverstärker



AX8000 | Multiachs-Servosystem




Original-Betriebsanleitung




Diagmessages für Achsmodule





Standard-Messages





Diagmessages of DeviceMainSlot





Diagmessages of module SafeMotion





Diagmessages of DeviceDebugSlot





Diagmessages of AxisMainSlot





Diagmessages of InterpolatorSlot





Diagmessages of PositionControlSlot





Diagmessages of VelocityControlSlot





Diagmessages of BiquadFilterSlot





Diagmessages of TorqueControlSlot





Diagmessages of FeedbackSlot






7320, HpfDsl: Encoder error (position invalid), Id=0xXX, Arg=0xXX






7380, HpfDsl: Encoder start sequence failed, Id=0xXX, Arg=0xXX






7381, HpfDsl: Encoder shutdown failed, Id=0xXX, Arg=0xXX






7382, HpfDsl: Parameter access error, Id=0xXX, Cmd=II, RID=0xXX, Offset=II, Len=II, LongMsgErrorCode=0xXX






7383, HpfDsl: Internal error, Id=0xXX, Arg=0xXX






7384, HpfDsl: Cyclic monitoring error, Id=0xXX, Arg=0xXX






7385, HpfDsl: Encoder file processing, Id=0xXX, WarnArg=0xXX






7386, HpfDsl: Found no encoder (No link to an encoder)!






7387, HpfDsl: The encoder doesn't meet the specified policies. Resolutionpolicy=II [Encoder=II, Requirement=II], Rangepolicy=II [Encoder=II, Requirement=II]






7388, HpfDsl: Encoder power off (triggered from SafeCu), Id=0xXX, Arg=0xXX






7389, HpfDsl: Encoder interface resistance check failed. Measured resistance is too low! R=II Ohm






738A, Loaded fpga is not verified.






738B, HpfDsl: Internal warning! The error inducer is available.






738C, HpfDsl: Encoder seems to be offline for UU cycles. (InternalDbg: UU)






738D, HpfDsl: Invalid encoder parameter, see SubIdx UU






738E, HpfDsl: Encoder file processing error, FileId=0xXX, Arg=0xXX






738F, HpfDsl: SafeCU monitored encoder status flag is set! The next fault reset triggers an encoder restart. EncST7..4=0xXX, EncST3..0=0xXX






7390, HpfDsl: Status dump, Encoder Status after IIms: Summary=0xXX, Regs 7..4=0xXX, Regs 3..0=0xXX






7391, HpfDsl: Status dump, Max occured position deviation=UU mdeg






7392, HpfDsl: Status dump, Error counter VPOS=UU, ACC=UU, VRT=UU, POS=UU, LINK=UU, Encoding=UU






7393, HpfDsl: A safety error condition is blocking the encoder voltage.






7394, HpfDsl: An overload or an open load state is detected on the 2WireInterface.






73C0, EnDat22: Encoder error (position invalid), Id=0xXX, Arg=0xXX






73C1, EnDat22: Encoder error (position invalid), Id=0xXX, Arg=0xXX






73C2, EnDat22: Encoder start failed, Id=0xXX, Arg=0xXX






73C3, EnDat22: Encoder shutdown failed, Id=0xXX, Arg=0xXX






73C4, EnDat22: Parameter access error, Id=0xXX, Cmd=II, Addr=0xXX, Len=II, Data=0xXX, FifoStatus=0xXX






73C5, EnDat22: Internal error, Id=0xXX, Arg=0xXX






73C6, EnDat22: Cyclic monitoring error, Id=0xXX, Arg=0xXX






73C7, EnDat22: Encoder file processing, Id=0xXX, WarnArg=0xXX






73C8, EnDat22: Encoder policy check (steps per revolution) failed, Enc=UU, PolicyValue=UU






73C9, EnDat22: Encoder policy check (distinguishable revolutions) failed, Enc=UU, PolicyValue=UU






73CA, EnDat22: Encoder policy check (step length) failed, Enc=0xXXXX, PolicyValue=0xXXXX






73CB, EnDat22: Encoder policy check (measuring length) failed, Enc=0xXXXX, PolicyValue=0xXXXX






73CC, EnDat22: The multiturn part of the transferred position value is not reliable, Id=0xXX, Arg=0xXX






73CD, EnDat22: Encoder power off (SafeCu global shutdown), Id=0xXX, Arg=0xXX






73CE, EnDat22: Found no encoder (No link to an encoder)!






73CF, EnDat22: The encoder position is received later as expected! Increase the wait time by IIns.






73D0, EnDat22: An 'extended reset' has triggered the reinitialization of the multiturn part of the transferred position, Id=0xXX, Arg=0xXX






73D1, EnDat22: User setting forces ignoring of incompatible encoder parameter. [MemRange II, Word II]






73D2, EnDat22: Incompatible encoder parameter [MemRange II, Word II] ignored or modified!






73D3, EnDat22: The encoder is incompatible. See MemRange II, Word II






73D4, Loaded fpga is not verified.






73D5, EnDat22: Select safety cycle content failed, Id=0xXX, Arg=0xXX






73D6, EnDat22: Internal warning! The error incuder is available.






73D7, EnDat22: The encoder don't support the selected valuation addresses, Supported=0xXX, Configured=0xXX






73D8, EnDat22: The selected valuations could not be read.






73D9, EnDat22: User setting forces a encoder start in the EnDat21 mode only! The 'position actual value' isn't available!






73FF, EnDat22: Internal Error, Additional Errorcode 0xXX






7780, SimulationEnc: Encoder simulation is not supported for the selected motor type. (ModuleIdent 0xXX)






77BF, SimulationEnc: Internal Error, Additional Errorcode 0xXX






77C0, BiSS-C: Encoder error (position invalid), Id=0xXX, Arg=0xXX






77C1, BiSS-C: Encoder error (position invalid), Id=0xXX, Arg=0xXX






77C2, BiSS-C: Encoder start failed, Id=0xXX, Arg=0xXX






77C3, BiSS-C: Encoder shutdown failed, Id=0xXX, Arg=0xXX






77C4, BiSS-C: Internal error, Id=0xXX, Arg=0xXX






77C5, BiSS-C: Cyclic monitoring error, Id=0xXX, Arg=0xXX






77C6, BiSS-C: Encoder warning active, Id=0xXX, Arg=0xXX






77C7, BiSS-C: Parameter error in object 0xXX/XX






77FF, BiSS-C: Internal Error, Additional Errorcode 0xXX






7880, EnDat3: Encoder error (position invalid), HPFstatus: F(0)=UU, HPFV(1)=UU, ERR_REQ(0)=UU, valid(1)=UU; ShortStatus: TrmErr(0)=UU (0xXX)






7881, EnDat3: Encoder error (position invalid), HPFstatus: F(0)=UU, HPFV(1)=UU, ERR_REQ(0)=UU, valid(1)=UU; ShortStatus: TrmErr(0)=UU (0xXX)






7882, EnDat3: Encoder error (position invalid), ForegroundErrorCode=0xXX






7883, EnDat3: Encoder error (position invalid), ForegroundErrorCode=0xXX






7884, EnDat3: Encoder error (position invalid), HPFvalid(1)=UU; ShortStatus: TrmError(0)=UU, HPFF(0)=UU (0xXX)






7885, EnDat3: Encoder error (position invalid), HPFvalid(1)=UU; ShortStatus: TrmError(0)=UU, HPFF(0)=UU (0xXX)






7886, EnDat3: Encoder error (position invalid), FGstatus: HPFF(0)=UU, CSerr(0)=UU, PhyErr(0)=UU, WDerr(0)=UU, StrobeErr(0)=UU (0xXX)






7887, EnDat3: Encoder error (position invalid), FGstatus: HPFF(0)=UU, CSerr(0)=UU, PhyErr(0)=UU, WDerr(0)=UU, StrobeErr(0)=UU (0xXX)






7888, EnDat3: Encoder start failed, Id=0xXX, Arg=0xXX






7889, EnDat3: Encoder shutdown failed, Id=0xXX, Arg=0xXX






788A, EnDat3: Parameter access error, hr=0xXX, BGreq=II, ErrorCode=0xXX, Data=0xXX, 0xXX






788B, EnDat3: Internal error, Id=0xXX, Arg=0xXX






788C, EnDat3: Cyclic monitoring error, Id=0xXX, Arg=0xXX






788D, EnDat3: Encoder start failed, ambiguous motor temperature sensor id, II <> II






788E, EnDat3: Encoder policy check (steps per revolution) failed, Enc=UU, PolicyValue=UU






788F, EnDat3: Encoder policy check (distinguishable revolutions) failed, Enc=UU, PolicyValue=UU






7890, EnDat3: Encoder policy check (step length) failed, Enc=0xXXXX, PolicyValue=0xXXXX






7891, EnDat3: Encoder policy check (measuring length) failed, Enc=0xXXXX, PolicyValue=0xXXXX






7892, EnDat3: Encoder interface resistance check failed. Measured resistance is too low! R=II Ohm






7893, EnDat3: Encoder power off (SafeCu global shutdown), Id=0xXX, Arg=0xXX






7894, EnDat3: Found no encoder (No link to an encoder)!






7895, EnDat3: Invalid memory area crc (memory base addr=0xXX).






7896, EnDat3: An encoder restart is required because the non-volatile encoder settings are modified (addr=0xXX).






7897, EnDat3: A safety error condition is blocking the encoder voltage.






7898, Electronic data sheet: No motor temperature sensor id






7899, Loaded fpga is not verified.






789A, EnDat3: Low priority frame error, SendListEntry x=UU, y=UU, z=UU, LPFstatus=0xXX, FGerrCode=0xXX






789B, EnDat3: Invalid memory area crc (memory base addr=0xXX).






789C, EnDat3: Encoder warning, Status=0xXX, LatchedStatus=0xXX






789D, EnDat3: Encoder status dump, HPFstatus: F(0)=UU, HPFV(1)=UU, ERR_REQ(0)=UU, valid(1)=UU; ShortStatus: TrmErr(0)=UU (0xXX)






789E, EnDat3: Encoder status dump, ForegroundErrorCode=0xXX






789F, EnDat3: Encoder status dump, HPFvalid(1)=UU; ShortStatus: TrmError(0)=UU, HPFF(0)=UU (0xXX)






78A0, EnDat3: Encoder status dump, FGstatus: HPFF(0)=UU, CSerr(0)=UU, PhyErr(0)=UU, WDerr(0)=UU, StrobeErr(0)=UU (0xXX)






78A1, EnDat3: Encoder seems to be offline for UU cycles. (InternalDbg: UU)






78A2, EnDat3: Encoder start warning, Id=0xXX, Arg=0xXXXX






78A3, EnDat3: An overload or an open load state is detected on the 2WireInterface.






78BF, EnDat3: Internal Error, Additional Errorcode 0xXX






78C0, Inc Enc: Encoder error (position invalid), Id=0xXX, Arg=0xXX






78C1, Inc Enc: Encoder error (position invalid), Id=0xXX, Arg=0xXX






78C2, Inc Enc: Encoder start failed, Id=0xXX, Arg=0xXX






78C3, Inc Enc: Encoder shutdown failed, Id=0xXX, Arg=0xXX






78C4, Inc Enc: Internal error, Id=0xXX, Arg=0xXX






78C5, Inc Enc: Cyclic monitoring error, Id=0xXX, Arg=0xXX






78C6, Inc Enc: Encoder warning active, Id=0xXX, Arg=0xXX






78C7, Inc Enc: SinCos Encoder error (Vector length to long), Vector length = FFV






78C8, Inc Enc: SinCos Encoder error (Vector length to short), Vector length = FFV






78C9, Inc Enc: SinCos Encoder error (SinCos period counting error)






78CA, Inc Enc: TTL Encoder error (Broken wire detected)






78CB, Inc Enc: TTL Encoder warning active, Id=0xXX, Arg=0xXX






78CC, Inc Enc: Parameter error in object 0xXX/XX






78FF, Inc Enc: Internal Error, Additional Errorcode 0xXX






FFFF, HpfDsl: Internal Error, Additional Errorcode 0xXX





Diagmessages of MotorSlot





Diagmessages of AxisDebugSlot




Objektbeschreibung für Achsmodule




Objektbeschreibung für Einspeisemodule




Diagmessages für Einspeisemodule



AX5000 | Digital Kompakt Servoverstärker



AX1000 | Economy-Servoverstärker


Frequenzumrichter


Dezentrale Antriebssysteme


Rotatorische Servomotoren


Translatorische Servomotoren


Planetengetriebe


XTS | Linearer Produkttransport


XPlanar | Planarmotorantriebssystem


Kompakte Antriebstechnik


Zubehör


Software


Archiv

TwinCAT 3

TwinCAT 2

MX-System

Branchenlösungen

Allgemeine Produktinformationen

Suche

News

Home