789E, EnDat3: Encoder status dump, ForegroundErrorCode=0xXX
The encoder position (first feedback) is invalid!
|
Diagnostic Code (Hex.) |
Diagnostic Code (Dez.) |
|---|---|
|
789E |
30878 |
|
Class |
Type |
|---|---|
|
Error |
Feedback error |
|
Standard Reaction |
Reset |
|---|---|
|
Closed loop ramp |
Execute Reset-Command (Fault reset). |
Internal: 0x789E, EnDat3: Encoder status dump, ForegroundErrorCode=0x%X