Mechanical installation
| |
Wear safety shoes Wear safety shoes when assembling the XTS Hygienic, as components may accidentally fall in the work area. Falling components can cause serious foot injuries. |
| |
Handle cutting tools carefully Use cutting tools with great care. Make sure that nobody in your immediate vicinity can be injured if the tool inadvertently slips. Wear protective gloves if necessary. Careless handling of cutting tools can lead to puncture wounds and cuts. |
| |
Handle adhesives with care Be careful when using adhesives. Observe the manufacturer's documentation. Wear protective gloves and safety glasses if necessary. Adhesive can irritate the eyes, respiratory tract, and skin. Do not inhale the vapor. Avoid eye and skin contact with the adhesive. If adhesive gets into your eyes, immediately rinse them thoroughly with water and seek medical attention. |
Notice | |
Establish a conductive connection between the motor modules and the machine bed For each motor module, remove the anodized coating from the machine bed at the location of the threaded hole marked Functional Ground to establish a conductive connection between the motor module and the machine bed. Ungrounded motor modules can cause a short circuit and damage the system. |
Before installing the motor modules, remove the anodized coating from the machine bed in a 10-mm diameter circle around each hole [1] that corresponds to the location of the threaded hole marked Functional Ground [2] on the motor module.
![]() | Avoid dirt When assembling the XTS Hygienic, make sure that all parts are free from dust and dirt. |
![]() | Check that the machine bed has been manufactured correctly Check before assembling whether the distances between the locating pins in the machine bed are correct. |
The distance from the center of the first locating pin hole for one motor module to the center of the first locating pin hole for the next motor module must be 250 mm. The manufacturing tolerance is ±0.05 mm.
![]() | Installation example This chapter contains information on the assembly of an XTS Hygienic with straight motor modules, curved segments, guide rails, and movers. The assembly is described using a system with a 3 m circumference as an example. |