FB_BaseMd

FB_BaseMd 1:

Extends the base class FB_Base by the functions of the machine data handling. The structure of the machine data is explained in more detail in the chapter Machine data.

Syntax:

FUNCTION_BLOCK FB_BaseMd EXTENDS FB_Base

FB_BaseMd 2: Properties

Name

Type

Access

Initial value

Description

Name

STRING

Get, Set

<SourceName>

Specifies the name of the class instance.

FB_BaseMd

MachineData

I_MdBaseContainer

Get

-

Interface for machine data handling.

FB_Base

BaseState

E_BaseState

Get

eNotHandled

Initialization state of the class instance.

Error

BOOL

Get

FALSE

Class is in an error state.

ResultMessage

I_AppMessage

Get

-

Access to the class-internal EventLogger.

[PROTECTED] _Name

STRING

Get

<SourceName>

.Name without leading 'fb'.

FB_BaseMd 3: Methods

Name

Description

Reset()

Resets the error state of the class.

FB_BaseMd

[PROTECTED] AddMdComp()

Adds a component of type I_MdComponent to the machine data container.

FB_Base

GetHMI()

Returns the assigned HMI object.

The method is not implemented in the FB_Base class. If the method is not overwritten by inheritance, a pseudo variable is always returned.

SetHMI(ipBase)

General assignment method for an FB_BaseHmi extending class as a local HMI.

The method is not implemented in the FB_Base class. If the method is not overridden by inheritance, it always fails.

[PROTECTED] _IsMyself(iCmp)

Identifies whether the transferred object corresponds to its own instance.

[PROTECTED] _QueryNamespace()

Extracts the first part of the instance path as an object namespace.

[PROTECTED] _QueryObjectName()

Extracts the last part of the instance path as the object name.

FB_BaseMd 4: Cycle methods

Name

Description

Cyclic()

Cycle method - Call once per PLC cycle (default 10 ms)

FB_BaseMd 5: Interfaces

Type

Description

I_Base

Standard interface on FB_Base.

I_BaseMd

Standard interface on FB_BaseMd.

I_BaseDev

Covers all methods and properties of the base class.

I_Comparable

Enables comparisons via _IsMyself() or F_IsSameInstance().

Requirements

Development environment

Target platform

PLC libraries to include

TwinCAT v3.1.4024.35

PC or CX (x64, x86)

Tc3_PlasticBaseApplication (>= v3.12.5.0)