MC_CamExchange

MC_CamExchange 1:

This function block exchanges cam table couplings on a slave. The cam table coupling that should be removed has to be active when this function block is executed and the activation condition is met, otherwise an error is triggered. Activation might depend either on the new entered cam table coupling (ActivationOptions.ReferenceObject = ECamActivationRef.NewlyEnteredCamTable) or on the one to be removed (ActivationOptions.ReferenceObject = ECamActivationRef.CamTableAlreadyInUse)

Syntax

Definition:

FUNCTION_BLOCK MC_CamExchange
VAR_INPUT
    Master                : Type_Master1D;
    Slave                 : Type_Camming1D;
    CamObjectToRemove     : Type_CouplingFunction1D;
    CamObjectToAdd        : Type_CouplingFunction1D;
    Execute               : BOOL;
    Scaling               : CamScalingData;
    ActivationOptions     : CamActivationOptions;
    ReactionToMasterError : EReactionToMasterError;
    ReactionToSlaveError  : EReactionToSlaveError;
END_VAR
VAR_OUTPUT
    InSync                : BOOL;
    Busy                  : BOOL;
    Active                : BOOL;
    CommandAborted        : BOOL;
    Error                 : BOOL;
    ErrorId               : UDINT;
    MasterHasError        : BOOL;
END_VAR

MC_CamExchange 2: Inputs

Name

Type

Default

Description

Master

Type_Master1D

 

Reference to the master axis

Slave

Type_Camming1D

 

Reference to the slave axis

CamObjectToRemove

Type_CouplingFunction1D

 

Cam object to be removed

CamObjectToAdd

Type_CouplingFunction1D

 

Cam object to be added

Execute

BOOL

 

Start cam exchange at rising edge.

Scaling

CamScalingData

 

Scaling of the new coupling

ActivationOptions

CamActivationOptions

 

Options controlling how the cam coupling is activated (mode, position, reference object).

ReactionToMasterError

EReactionToMasterError

TriggerSlaveError

Reaction if an error occurs in the master while this command is active.

ReactionToSlaveError

EReactionToSlaveError

TriggerMasterError

Reaction if an error occurs in the slave while this command is active.

MC_CamExchange 3: Outputs

Name

Type

Description

InSync

BOOL

Synchronization succeeded

Busy

BOOL

Function block is not finished and new output values are to be expected.

Active

BOOL

Function block has active control on the axis.

CommandAborted

BOOL

Command is aborted by another command.

Error

BOOL

Error occurred within function block.

ErrorId

UDINT

Error identifier

MasterHasError

BOOL

Master is in error state.

Version information

  • TwinCAT Standard >= v3.1.4026.23.1
  • TF5550 MC3 Camming >= v4.0.6 (includes TF5500 MC3 Base >= v4.0.6)

Required License

TC3 MC3 Camming