Transformation parameters (P-AXIS-00370)
P-AXIS-00370  | Transformation parameters of axis specific command value transformation  | |
Description  | The transformation parameters are entered in this array corresponding to the selected transformation ID P-AXIS-00369 .  | |
Parameter  | trafo.command_pos.param[i] where i = 0 … 74 (Maximum number of transformation parameters,  | |
Data type  | REAL64  | |
Data range  | Meaning (depends on transformation ID) ID 1: e-function param[0] h (*) in 1.0 E-4 mm param[1] k0 (*) param[2] k1 (*) param[3] k2 (*) param[4] fNorm Normalisation of motor angle (*) in 1.0 E-4° (*see equations of the functions) 
 ID 2: Crank function param[0] Crank length l1 in 1.0 E-4 mm param[1] Con-rod length l2 in 1.0 E-4 mm param[2] Eccentricity e param[3] Solution range for motor angle fM 0:.0-180 degrees 1: 180-360 degrees param[4] Moving direction of linear axis 0: positive 1: negative param[10] Zero point offset of linear axis In 1.0 E-4 mm 
 ID 3: Eccenter function param[0] Eccenter radius R in 1.0 E-4 mm param[1] Offset zero position linear axis In 1.0 E-4 mm param[2] Offset zero position rotary axis in 1.0 E-4° param[3] Solution range angle j 0:.-90..+90 degrees 1: 90..270 degrees 
 ID 4: Slider crank kinematic param[0] la Distance 1 hinge points In 1.0 E-4 mm param[1] lb Distance 2 hinge points In 1.0 E-4 mm param[2] Crank length lh in 1.0 E-4 mm param[3] Offset zero position linear axis In 1.0 E-4 mm param[4] Rotation direction of rotary axis B 0: positive 1: negative 
 ID 5: Angular kinematic param[0] l1 Length 1 in 1.0 E-4 mm param[1] l2 Length 2 in 1.0 E-4 mm param[2] Stroke length lh in 1.0 E-4 mm param[3] Lower limit of angle excursion in 1.0 E-4° param[4] Upper limit of angle excursion in 1.0 E-4° param[5] Position offset for linear axis in 1.0 E-4 mm (as of V3.1.3107.46/ V4.7.0) param[6] Angle offset of angle excursion in 1.0 E-4°(as of V3.1.3107.52) param[7] Angle inversion (as of V3.1.3107.52) 0:.no angle inversion 1: Angle value is inverted. param[8] Inversion of linear position (as of V3.1.3107.52) 0: no inversion 1: Linear position is inverted. 
 ID 6: Symmetrical slider crank param[0] Crank length/con-rod length l in 1.0 E-4 mm param[1] Offset zero position linear axis In 1.0 E-4 mm param[2] Zero point offset of rotary axis 1.0 E-4° param[3] Solution range for motor angle fM 0:.0-180 degrees 1: 180-360 degrees 
  | |
Axis types  | R  | |
Dimension  | 
  | R: ----  | 
Default value  | 0  | |
Drive types  | ----  | |
Remarks  | 
  | |