FB_AX2000_Parameter
Reading/writing the parameters via the parameter channel.
VAR_INPUT
VAR_INPUT
iSlaveAddress : BYTE := 0; (* Station Address of the Slave *)
iPnu : WORD := 16#03A2; (* Parameter-Number *)
nAxis : BYTE := 1; (* Number of Axis *)
iLength : BYTE := 4; (* Length of the parameter (2 or 4) *)
iParameterValue : DWORD := 2; (* Parameter value *)
iFC310xDeviceId : WORD := 1; (* Device-ID of the FCxxxx *)
bStartRead : BOOL; (* StartFlag to start the PKW-Read *)
bStartWrite : BOOL; (* StartFlag to start the PKW-Write *)
tTimeOut : TIME:=t#5s;
END_VAR
iSlaveAddress: Station address.
iPnu: Selection of the parameter to be read or written. List of the available parameter numbers.
nAxis: Axis ID.
iLength: Length of the parameter (2 or 4).
iParameterValue : Value of the parameter to be read or written.
iFC310xDeviceId : Device-Id
bStartRead : A rising edge at this boolean input sends a command to the axis to start reading the parameters selected with "Pnu".
bStartWrite : A rising edge at this boolean input sends a command to the axis to start writing the parameters selected with "Pnu".When changing operating mode, the write command is only effective if Stop = TRUE at the FB_AX2000_AXACT block.
tTimeOut: The maximum timeout - this time must not be exceeded.
VAR_OUTPUT
VAR_OUTPUT
bBusy :BOOL;
iErrorId :DWORD;
iReadValue :DINT;
END_VAR
bBusy : This output remains TRUE until the block has executed a command. While Busy = TRUE, no new command will be accepted at the inputs. Please note that it is not the execution of the service but its acceptance whose time is monitored.
iErrorId : Contains the command-specific error code of the most recently executed command. Is reset to 0 by the execution of an instruction at the inputs.
iReadValue : Parameter value as a response to the "StartRead" command.
Requirements
Development Environment | Target System | IO Hardware | PLC Libraries to include |
|---|---|---|---|
TwinCAT v2.8.0 Build > 737 | PC (i386) | AX2000 Profibus box | TcIoFunctions.Lib ( Standard.Lib; TcBase.Lib; TcSystem.Lib; TcUtilities.Lib are included automatically ) |