General command overview
Command | Description | block-by-block / | Default |
---|---|---|---|
Contour line programming (angle) | s |
| |
Rotation additive | m |
| |
Calculates the inverse rotation of a vector | s |
| |
Calculates the rotation of a vector | s |
| |
Bottleneck detection off | m | Default | |
Bottleneck detection on | m |
| |
Constant velocity at the contour | m | Default | |
Constant velocity in the interior circle | m |
| |
Constant velocity of tool center point | m |
| |
Circular interpolation | s |
| |
Centre point correction off | m |
| |
Centre point correction on | m | Default | |
Delete Distance to Go | s |
| |
Dynamic Override | m |
| |
Constant feed programming | m | Default | |
Linear feed programming | m |
| |
Rapid traverse | m |
| |
Straight line interpolation | m | Default | |
Clockwise arc interpolation | m |
| |
Anticlockwise arc interpolation | m |
| |
Dwell time | s |
| |
Accurate stop | s |
| |
Plane selection XY | m | Default | |
Plane selection ZX | m |
| |
Plane selection YZ | m |
| |
No miller/cutter radius compensation | m | Default | |
Miller/cutter radius compensation left | m |
| |
Miller/cutter radius compensation right | m |
| |
Zero shift suppression | m | Default | |
1. adjustable zero shift | m |
| |
2. adjustable zero shift | m |
| |
3. adjustable zero shift | m |
| |
4. adjustable zero shift | m |
| |
1. programmable zero offset shift | m |
| |
2. programmable zero offset shift | m |
| |
Accurate stop | m |
| |
Dimensions inch | m |
| |
Dimensions metric | m | Default | |
Programmed traverse to reference point | s |
| |
Reference dimension notation | m | Default | |
Incremental dimension notation | m |
| |
Dimensions in inches with calculation of the feed | m |
| |
Dimensions metric with calculation of the feed | m |
| |
Mirroring coordinate system | m |
| |
Modulo movement | s |
| |
Messages from the NC program | s |
| |
Orthogonal approach of and departure from the contour | s |
| |
Feed direction positive | m | Default | |
Feed direction negative | m |
| |
Automatic Accurate Stop | m |
| |
Parameterization of the axis dynamics | m |
| |
C1 reduction factor | m |
| |
C2 reduction factor | m |
| |
Circular smoothing | m |
| |
C0 reduction - deflection angle | m |
| |
Circular smoothing (old) | m |
| |
Pathway dynamics (old) | m |
| |
Pathway dynamics | m |
| |
Circular accuracy | m |
| |
Smoothing with Bezier Splines | m |
| |
Smoothing of Segment Transitions | m |
| |
C0 reduction - max. step change in velocity | m |
| |
Minimum velocity | m |
| |
Parameterization of the configurable zero shift | m |
| |
Reads the actual position | s |
| |
Absolute rotation | m |
| |
Extended rotation function off | m | Default | |
Extended rotation function on | m |
| |
Calculation routine for rotating a vector | s |
| |
Initialization of R-parameters | s |
| |
Converts an R-parameter to DWord and checks whether a defined bit is set | m |
| |
Contour line programming (segment length) | s |
| |
Skip virtual movements | m |
| |
Cartesian tool displacement and length compensation is not applied under G91 | m |
| |
Cartesian tool displacement and length compensation is applied under G91 | m | Default | |
Writing and reading of tool parameters | m |
| |
Target position monitoring | s |
| |
Zero shift is not applied under G91 | m |
| |
Zero shift is applied under G91 | m | Default |
Address | Description |
---|---|
Axis label for auxiliary axis ( 1 <= n <= 5) |