Spindle

Spindle programming is performed in accordance with the conventional standard syntax defined in ISO resp. ISO + extensions. This is required in particular for reasons relating to compatibility and owing to certain standard functionalities such as turning, tapping and gear changing etc.

To comply with the requirements of new machine concepts and production technologies in flexible spindle programming, each spindle present on the channel also features the option of axis-specific programming. This syntax allows several spindles to be addressed mutually independently in multi-spindle systems in one NC-block simultaneously [1]-20, [6]-8.8. In this case, it must be noted that only one spindle can be programmed at one time, the so-called "main spindle", both in the standard syntax and in the spindle-specific syntax. All other spindles can be addressed only via the spindle-specific syntax (Chapter Programming in spindle-specific syntax).

Spindle 1:

The spindles and the main spindle are defined in the channel parameters list [1]-16. This configuration is available after boot-up of the control system. The main spindle can be changed in the NC-program by means of an NC-command (#MAIN SPINDLE, Chapter Change of main spindle).

The table below shows what NC-commands must be used in conjunction with spindle programming only in the DIN syntax and what NC-commands are also allowed within the extended spindle-specific syntax.

Tab. 14-1: Overview of all spindle relevant commands

Description

DIN-Syntax

Spindle specific Syntax

Spindle-M-Functions

M3, M4, M5, M19

M3, M4, M5, M19

Speed

S

REV

Position

S.POS

POS

User specific
M/H-Functions

Mxx/Hxx

Mxx/Hxx

Gear change (mechanical)

M40-M45

 

Thread cutting

G33

 

Tapping

G63

 

Turning

G95, G96, G97, G196

 

C-axis

#CAX

 

Gear change (new data)

G112

 

Homing

G74

G74

Override 100%

G167

G167

Requesting
of a spindle axis

 

CALLAX

Releasing
of a spindle axis

 

PUTAX

Taking over new
tool dynamic data

 

GET_DYNAMIC_DATA

Feedforward control

 

G135, G136, G137

Feed linking

 

FEED_LINK