ID-range 50250-50499

ID-range 50250-50499

50250 / 50251

Troubleshooting classes

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

6

 

Solution

Class

8

Restart of NC-control necessary.

50253

Limiting velocity for polynomial smaller than permissible value.

 

Description

The value for P-AXIS-00130 was set below its lower limit.

Reaction

Class

6

Stopp of axis.

Solution

Class

7

Set P-AXIS-00130 above its lower limit.

Error type

-

 

50254

Unknown acceleration type.

 

Description

An invalid value for parameter P-AXIS-00202 was entered when setting up curve-controlled acceleration. See also [FCT-S1, Spindle - chapter characteristic curve-controlled acceleration].

Reaction

Class

6

Immediate stop of axis.

Solution

Class

7

Assign valid value to P-AXIS-00202

Error type

-

 

50255 - 50259

Troubleshooting classes

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

6

 

Solution

Class

8

Restart of NC-control necessary.

50260

Non linear SLOPE while homing not allowed.

 

Description

Wrong slope profile selected with torque limited homing. This homing type is only possible with linear slope profile.

Further information to slope profiles see [PROG], [CHAN, Channel Parameter].

Reaction

Class

6

Movement stop.

Solution

Class

6

Change slope profile in machine data P-CHAN-00071 or via NC-command #SET SLOPE PROFILE[0] to linear type.

Parameter

%1:

Actual value [-]

Selected slope profile.

Error type

1, Error message from NC-program.

 

50262

Virtual and other axes are take part mixed at measurement.

 

Description

With the use of measurement function G100 virtual axes and axes with other drive type (P-AXIS-00020) are used mixed in measurement axes group. This is not allowed.

Further information to measurement function G100 see,.

Reaction

Class

4

Movement stop of axes.

Solution

Class

6

Use either all axes of measurement group with drive type virtual or all measurement axes with other drive type (P-AXIS-00020).

Parameter

%1:

Actual value [-]

Number of measurement axes in measurement group.

%2:

Actual value [-]

Programmed axes of measurement axes group.

Error type

1, Error message from NC-program.

 

50263

Moved main axis in MDS not marked as KASTO-axis.

 

Description

In functionality edge banding before start of edge banding process moved axes are checked whether they are marked or not as edge banding axis P-CHAN-00098. Only main axis can be marked as edge banding axis.

Further information to edge banding see.

Reaction

Class

4

Movement stop.

Solution

Class

6

Setting P-CHAN-00098 to 1 in affected axis.

Parameter

%1:

Logical axis number [-]

Logical axis number of affected axis P-AXIS-00016.

Error type

1, Error message from NC-program.

 

50264 - 50272

Troubleshooting classes

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

6

 

Solution

Class

8

Restart of NC-control necessary.

50275

No homing of axes allowed while tracking operation.

 

Description

 

Reaction

Class

4

 

Solution

Class

6

 

Parameter

%1:

Logical axis number [-]

 

Error type

1, Error message from NC-program.

 

50277

Troubleshooting classes

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

6

 

Solution

Class

8

Restart of NC-control necessary.

50278

Selection of manual mode in the turning center.

 

Description

In C-axis face milling functionality the cartesian programmers coordinate system is transformed to cylinder machine coordinate system. If milling head is in center point of this coordinate system so activation of manual mode isn´t possible.

Reaction

Class

4

Movement stop.

Solution

Class

6

Moving linear machine axis which lays in XY plane out of turning center position with inactive transformation.

Error type

1, Error message from NC-program.

 

50279

Troubleshooting classes

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

4

 

Solution

Class

8

Restart of NC-control necessary.

50280

Velocity for manual mode cannot be reached in given cycles.

 

Description

In C-axis face milling functionality the cartesian programmers coordinate system is transformed to cylinder machine coordinate system. In turning center dynamical high stress can occur.

With active manual mode the maximum permissible axis velocity in MDS P-AXIS-00213 will be limited.

Reaction

Class

1

None.

Solution

Class

1

 

Parameter

%1:

Logical axis number [-]

 

%2:

Actual value [1µm/sec or 0,001°/sec]

 

%3:

Limit value [1µm/sec or 0,001°/sec]

 

Error type

1, Error message from NC-program.

 

50281

Error while calculating filter coefficients.

 

Description

The coefficients of an axis filter could not be calculated.

Possible error causes are:

  • P-AXIS-00080 was set to zero in the axis parameter list.
  • The value of P-AXIS-00067 is bigger than 0.5 / (Interpolator cycle time).
  • The filter coefficients resulting from the filter setup do not lead the desired filter behavior.

Reaction

Class

2

Abortion of program.

Solution

Class

7

Correct wrong parameter.

Parameter

%1:

Logical axis number [-]

Logical axis number.

%2:

Actual value [-]

Index of filter that caused the error message.

Error type

-

 

50282 - 50346

Troubleshooting classes

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

6

 

Solution

Class

8

Restart of NC-control necessary.

50350

Time for movement too short.

 

Description

Feed for movement can be programmed for independent axis with keyword “FEED” or “TIME” either as velocity or movement time. Time for movement value should be greater than a minimum limit value.

For detailed information to independent axis functionality see.

Reaction

Class

6

Movement stop of axis.

Solution

Class

7

Programmed value movement time greater than lower limit value.

Parameter

%1:

Logical axis number [-]

Logical axis number of affected axis

%2:

Actual value [1µm/sec or 0,001°/sec]

Programmed value for movement time

%3:

Lower limit value [1µm/sec or 0,001°/sec]

Lower limit value for movement time

Error type

1, Error message from NC-program.

 

50351

Fatal SERCOS-error.

 

Description

In case of synchronous read or write of a sercos id, the service channel reports an unknown error. The id could not be read or write.

Reaction

Class

4

 

Solution

Class

6

 

Parameter

%1:

Logical axis number [-]

 

%2:

Ident number [-]

 

%3:

Actual value [-]

 

%4:

Actual value [-]

 

Error type

1, Error message from NC-program.

 

50352

Troubleshooting classes

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

4

 

Solution

Class

8

Restart of NC-control necessary.

50354

SERCOS-Param.: Unknown SERCOS-id.

 

Description

Read or write command for SERCOS parameter in CNC program via #IDENT WR[], #IDENT RD[] failed because of incorrect or wrong SERCOS-ID.

Further information to functionality see.

Reaction

Class

4

Movement stop.

Solution

Class

6

Check SERCOS-ID in CNC program.

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of affected axis.

%2:

Ident number [-]

Programmed SERCOS ident number.

%3:

Actual value [-]

SERCOS return code 1.

%4:

Actual value [-]

SERCOS return code 2.

Error type

1, Error message from NC-program.

 

50355

SERCOS-Param.: Data size too short.

 

Description

Read or write command for SERCOS parameter in CNC program via #IDENT WR[], #IDENT RD[] failed because of incorrect or wrong data length and type of SERCOS-ID.

Further information to functionality see.

Reaction

Class

4

Movement stop.

Solution

Class

6

Check data type and length of SERCOS parameter.

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of affected axis.

%2:

Ident number [-]

Programmed SERCOS ident number.

%3:

Actual value [-]

SERCOS return code 1.

%4:

Actual value [-]

SERCOS return code 2.

Error type

1, Error message from NC-program.

 

50356

SERCOS-Param.: Data size too long.

 

Description

Read or write command for SERCOS parameter in CNC program via #IDENT WR[], #IDENT RD[…] failed because of incorrect or wrong data length and type of SERCOS-ID.

Reaction

Class

4

Movement stop.

Solution

Class

6

Check data type and length of SERCOS parameter.

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of affected axis.

%2:

Ident number [-]

Programmed SERCOS ident number.

%3:

Actual value [-]

SERCOS return code 1.

%4:

Actual value [-]

SERCOS return code 2.

Error type

1, Error message from NC-program.

 

50357

SERCOS-Param.: Date cannot be change.

 

Description

Write command for SERCOS parameter in CNC program via #IDENT WR[] failed because parameter cannot be changed.

Further information to functionality see.

Reaction

Class

4

Movement stop.

Solution

Class

6

Only #IDENT RD[] is allowed with selected SERCOS ident.

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of affected axis.

%2:

Ident number [-]

Programmed SERCOS ident number.

%3:

Actual value [-]

SERCOS return code 1.

%4:

Actual value [-]

SERCOS return code 2.

Error type

1, Error message from NC-program.

 

50358

SERCOS-Param.: Date is in this time write protect.

 

Description

Write command for SERCOS parameter in CNC program via #IDENT WR[] failed because parameter is write protected at the moment.

Further information to functionality see.

Reaction

Class

4

Movement stop.

Solution

Class

6

Only #IDENT RD[] is possible with selected SERCOS ident.

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of affected axis.

%2:

Ident number [-]

Programmed SERCOS ident number.

%3:

Actual value [-]

SERCOS return code 1.

%4:

Actual value [-]

SERCOS return code 2.

Error type

1, Error message from NC-program.

 

50359

SERCOS-Param.: Date shorter as min. value.

 

Description

Write command for SERCOS parameter in CNC program via #IDENT WR[] failed because parameter smaller than minimum value.

Further information to functionality see.

Reaction

Class

4

Movement stop.

Solution

Class

6

Programming of parameter value in valid range.

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of affected axis.

%2:

Ident number [-]

Programmed SERCOS ident number.

%3:

Actual value [-]

SERCOS return code 1.

%4:

Actual value [-]

SERCOS return code 2.

Error type

1, Error message from NC-program.

 

50360

SERCOS-Param.: Data size too long.

 

Description

Write command for SERCOS parameter in CNC program via #IDENT WR[] failed because parameter greater than maximum value.

Reaction

Class

4

Movement stop.

Solution

Class

6

Programming of parameter value in valid range.

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of affected axis.

%2:

Ident number [-]

Programmed SERCOS ident number.

%3:

Actual value [-]

SERCOS return code 1.

%4:

Actual value [-]

SERCOS return code 2.

Error type

1, Error message from NC-program.

 

50361

SERCOS-Param.: Date incorrect.

 

Description

Write or read of SERCOS parameter with wrong date.

Weitere Informationen zur Funktionalität siehe [PROG].

Reaction

Class

4

Movement stop.

Solution

Class

6

Check and correct SERCOS parameter.

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of affected axis.

%2:

Ident number [-]

Programmed SERCOS ident number.

%3:

Actual value [-]

SERCOS return code 1.

%4:

Actual value [-]

SERCOS return code 2.

Error type

1, Error message from NC-program.

 

50362

Other error by data transfer in service channel.

 

Description

Error occurred with data transfer of SERCOS parameter or orders.

Weitere Informationen zur Funktionalität siehe [PROG].

Reaction

Class

4

Movement stop.

Solution

Class

6

Check drive and communication.

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of affected axis.

%2:

Ident number [-]

Programmed SERCOS ident number.

%3:

Actual value [-]

SERCOS return code 1.

%4:

Actual value [-]

SERCOS return code 2.

Error type

1, Error message from NC-program.

 

50363 - 50381

Troubleshooting classes

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

4

 

Solution

Class

8

Restart of NC-control necessary.

50384

Inadmissible number of late sync function reached.

 

Description

The overall sum of active late synchronization type M codes at the same time (late sync, types MVS_SLM, MVS_SLP) is limited. After trigger event of active codes with G01 movement block or explicit trigger via NC command the M codes are active until synchronization with PLC.

For more detailed information about M-H- codes see.

Reaction

Class

1

Warning.

If in the following time further M codes are programmed and no late synchronization M codes are acknowledged by PLC, the path movement stops also without late sync M code trigger after a fixed number of M codes (internal buffer).

Solution

Class

1

Reduction of programmed late synchronization M-codes in one NC block and overall sum until trigger event.

Parameter

%1:

Actual value [-]

Number of current active late synchronization M-codes.

%2:

Upper limit value [-]

Upper limit of overall active late synchronization M- codes.

Error type

-

 

50385 - 50387

Troubleshooting classes

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

4

 

Solution

Class

8

Restart of NC-control necessary.

50388

Inadmissible number of late sync function in the channel.

 

Description

The sum of channel specific late synchronization type M codes (late sync, types MVS_SLM, MVS_SLP) programmed in one NC row is limited. After trigger event of active codes with G01 movement block or explicit trigger via NC command the M codes are active until synchronization with PLC.

For more detailed information about M-H- codes see.

Reaction

Class

4

Movement stop of axes

Solution

Class

6

Reduction of programmed axis specific late synchronization M-codes in one NC block.

Parameter

%1:

Actual value [-]

Block number in NC program

%2:

Limit value [-]

Number of current programmed channel specific late synchronization M-codes in one NC program row.

Error type

1, Error message from NC-program.

 

50389

Inadmissible number of late sync function in axes.

 

Description

The sum of axis specific late synchronization type M codes (late sync, types MVS_SLM, MVS_SLP) programmed in one NC row is limited. After trigger event of active codes with G01 movement block or explicit trigger via NC command the M codes are active until synchronization with PLC.

For more detailed information about M-H- codes see.

Reaction

Class

4

Movement stop of axes.

Solution

Class

6

Reduction of programmed axis specific late synchronization M-codes in one NC block.

Parameter

%1:

Logical axis number [-]

Logical axis number of affected axis .

%2:

Block number [-]

Row number in NC program.

%3:

Actual value [-]

Number of current programmed late synchronization M-codes in axis and NC program row.

%4:

Limit value [-]

Upper limit of late synchronization M- codes per axis and NC program row.

Error type

-

 

50391 - 50397

Troubleshooting classes

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

6

 

Solution

Class

8

Restart of NC-control necessary.

50398

No edge banding axes in MDS marked.

 

Description

In functionality edge banding before start of edge banding process axes are checked whether they are marked or not as edge banding axis P-CHAN-00098. At least one main axis has to marked as edge banding axis.

Further information to edge banding see.

Reaction

Class

4

Movement stop.

Solution

Class

6

Set P-CHAN-00098 for at least one main axis to 1.

Error type

1, Error message from NC-program.

 

50399 - 50401

Troubleshooting classes

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

6

 

Solution

Class

8

Restart of NC-control necessary.

50403

Probe is already in operation.

 

Description

Before starting edge banding movement current signal status of measurement signal is checked. The signal should be inactive.

Further information to edge banding see.

Reaction

Class

4

Movement stop, termination of edge banding process.

Solution

Class

6

Check probe and signal level.

Parameter

%1:

Logical axis number [-]

Logical axis number of affected axis P-AXIS-00016.

Error type

1, Error message from NC-program.

 

50404

Initialization error in kinematic transformation.

 

Description

With function block search and automatically move to contour start point initialization / parameterization error in kinematic transformation has occurred.

Further information to kinematic transformation see [KITRA, Kinematic Transformation], [PROG].

Reaction

Class

6

Movement stop.

Solution

Class

6

Check and correction of kinematic transformation parameters in MDS or tool management.

Parameter

%1:

Actual value [-]

 

Error type

1, Error message from NC-program.

 

50405 - 50410

 

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

4

 

Solution

Class

8

Restart of NC-control necessary.

50411

Timeout by PLC reset channel.

 

Description

Request for CNC Reset of channel was not acknowledged by PLC in required time limit.

Reaction

Class

4

Movement stop.

Solution

Class

6

CNC reset.

Check PLC task and PLC project.

Parameter

%1:

Upper limit value [1 µsec]

Maximum time difference for reset acknowledge after reset request.

Error type

-

 

50412

Timeout by PLC reset axes.

 

Description

Request for CNC Reset of axis was not acknowledged by PLC in required time limit.

Reaction

Class

4

Movement stop.

Solution

Class

6

CNC reset.

Check PLC task and PLC project.

Parameter

%1:

Actual value [-]

Logical axis number P-AXIS-00016 of affected axis

%2:

Upper limit value [1 µsec]

Maximum time difference for reset acknowledge after reset request.

Error type

-

 

50417

SERCOS-command not feasible.

 

Description

The SERCOS order commanded in CNC program with #COMMAND WR[], #COMMAND WR SYN[] is not feasible.

Further information to functionality see.

Reaction

Class

4

Movement stop.

Solution

Class

6

Check and correct programmed SERCOS order.

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of affected axis.

%2:

Ident number [-]

Programmed SERCOS ident number.

%3:

Actual value [-]

Data state

%4:

Actual value [-]

SERCOS return code 1.

%5:

Actual value [-]

SERCOS return code 2.

Error type

1, Error message from NC-program.

 

50418

Machine data cannot be taken over.

 

Description

The programmed machine data could not be actualized in the control. The cnc command has no effect.

Test the syntax of the programmed command, [PROG].

Example:

#MACHINE DATA [AX X “getriebe[0].kv 1000”]

Reaction

Class

3

 

Solution

Class

6

 

Error type

1, Error message from NC-program.

 

50419 - 50427

 

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

6

 

Solution

Class

8

Restart of NC-control necessary.

50428

Turning function not allowed in theoretical path movement simulation.

 

Description

While active path movement simulation no turning functionality is supported.

Reaction

Class

6

Movement stop.

Solution

Class

7

Remove turning function in NC program at reported NC block number.

Parameter

%1:

Actual value [-]

 

%2:

Expected value [-]

 

Error type

-

 

50429

No drive guided referencing for GANTRY axis permissible.

 

Description

After command from CNC control Intelligent digital drives like SERCOS can do homing self controlled.

With gantry axes no drive controlled homing possible, because no synchronous homing movement is possible without additional actions.

Further information to gantry axes see

Reaction

Class

6

Movement stop.

Solution

Class

6

Check correct drive parameter settings for gantry homing.

Set axis parameter P-AXIS-00253 to 1.

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of affected axis

%2:

Actual value [-]

Axis mode of axis P-AXIS-00015

%3:

Actual value [-]

Drive type of axis P-AXIS-00018

Error type

1, Error message from NC-program.

 

50430

Release for min. one axes in manual mode unsuccessful.

 

Description

Enable for at least one axis for manual mode not possible.

Further information to manual mode see,.

Reaction

Class

4

Movement stop.

Solution

Class

6

Check if axis is in NC-Channel available.

Check selection and enable command for manual mode axis in NC program or PLC project. Is axis already enabled.

Error type

1, Error message from NC-program.

 

50431

Drop for min. one axes out of manual mode unsuccessful.

 

Description

Disable of at least one axis for manual mode not possible.

Further information to manual mode see,.

Reaction

Class

4

Movement stop.

Solution

Class

6

Check if axis is available in CNC-Channel.

Check deactivation and disable command for manual mode axis in NC program or PLC project. Is axis already disabled ?

Error type

1, Error message from NC-program.

 

50432 - 50434

Troubleshooting classes

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

4

 

Solution

Class

8

Restart of NC-control necessary.

50438

Edge banding incorrect or finished.

 

Description

Path to go is driven with active functionality edge banding after activation of measurement signal via sensor moving ahead. Depending on channel parameter P-CHAN-00029 the measurement signal must appear in one active movement block or until end of edge banding functionality.

Further information to edge banding see.

Reaction

Class

4

Movement stop.

Solution

Class

6

Check probe and signal,

Measurement signal during active edge banding movement.

Error type

1, Error message from NC-program.

 

50439 - 50442

Troubleshooting classes

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

4

 

Solution

Class

8

Restart of NC-control necessary.

50443

Path to go for edge banding to small.

 

Description

Path to go P-CHAN-00030 defined in channel parameter list is driven with active functionality edge banding after activation of measurement signal via sensor moving ahead. The path distance of measurement actual positions and target positions at this moment must be smaller than P-CHAN-00030.

Further information to edge banding see.

Reaction

Class

4

Movement stop.

Solution

Class

6

Increasing of P-CHAN-00030.

Parameter

%1:

Actual value [0.1 µm or 0,0001°]

Current active edge banding path to go P-CHAN-00030.

%2:

Actual value [0.1 µm or 0,0001°]

Path distance in space of measurement actual positions and target positions.

Error type

-

 

50444 - 50448

Troubleshooting classes

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

6

 

Solution

Class

8

Restart of NC-control necessary.

50449

Start of storage reached during backward movement, no further backward movement possible.

 

Description

In functionality backward movement the maximum number of blocks for backward movement depends on available buffer size P-STUP-00033.

Large CNC program can lead to limitation of possible backward movement.

Further information to backward movement see

Reaction

Class

1

None.

Solution

Class

1

Increase size of backward movement buffer P-STUP-00033.

Error type

-

 

50450

Given storage for backward movement smaller than minimum limit.

 

Description

In functionality backward movement the maximum number of blocks for backward movement depends on available buffer size P-STUP-00033.

Buffer size must be greater than minimum value.

Further information to backward movement see

Reaction

Class

-

Movement stop.

Solution

Class

-

Increase size of backward buffer memory P-STUP-00033.

Parameter

%1:

Limit value [-]

Current available buffer size.

%2:

Corrected value [-]

Required buffer size.

Error type

-

 

50451

Troubleshooting classes

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

6

 

Solution

Class

8

Restart of NC-control necessary.

50452

Axis moved during suppress of program lines.

 

Description

In functionality backward movement special marked blocks can be skipped under certain conditions if moving is done in backward / forward buffer (#OPTIONAL EXECUTION).

One essential condition is that axis positions at start point of marked area must be the same as the positions at the end of the marked area.

Further information to backward movement see.

Reaction

Class

2

Movement stop.

Solution

Class

7

Modification of CNC program to ensure to have same axes positions at start and end point of marked program sequence.

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of affected axis.

%2:

Actual value [0.1 µm or 0,0001°]

Axis position at the end of marked program sequence.

%3:

Expected value [0.1 µm or 0,0001°]

Required axis position at the end of marked program sequence.

Error type

1, Error message from NC-program.

 

50453

Change impossible, because backward storage is off.

 

Description

In functionality backward movement on path PLC signal MCControlBoolUnit_ResetBackwardStorage.X_Com and is active, this means backward movement buffer is disabled by PLC.

Further information to backward movement see

Reaction

Class

1

None.

Solution

Class

1

Set PLC BOOLEAN signal MCControlBoolUnit_ResetBackwardStorage.X_Command to FALSE.

Error type

-

 

50454

No clear of storage during backward on path possible.

 

Description

In functionality backward movement on path PLC signal MCControlBoolUnit_ResetBackwardStorage.X_Comm and is activated although backward movement is active. In this case backward movement buffer isn´t cleared.

Further information to backward movement see

Reaction

Class

1

None.

Solution

Class

1

No use of PLC signal MCControlBoolUnit_ResetBackwardStorage.X_Command if backward movement is active.

Error type

-

 

50455

Turn storage on/off not possible if program is in execution.

 

Description

In functionality backward movement on path PLC signal MCControlBoolUnit_ResetBackwardStorage.X_Comm and is activated although program execution is active. In this case backward movement buffer can´t be enabled or disabled.

Further information to backward movement see

Reaction

Class

1

None.

Solution

Class

1

No use of PLC signal MCControlBoolUnit_ResetBackwardStorage.X_Command if program execution is active.

Error type

-

 

50456 - 50461

Troubleshooting classes

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

4

 

Solution

Class

8

Restart of NC-control necessary.

50462

Logical interpolator axis cannot relate to the physical position-controller axis.

 

Description

Axis link from drive to channel interpolator based on parameters P-AXIS-00101, P-AXIS-00040 with multiple axis instantiation was not successful.

Reaction

Class

2

Movement stop of axis.

Solution

Class

7

Check multi instantiation of axis with axis configuration and parameters P-AXIS-00101, P-AXIS-00040.

Parameter

%1:

Logical axis number [-]

Logical axis number of affected channel interpolator axis P-AXIS-00016

%2:

Incorrect value [-]

Acknowledged logical axis number P-AXIS-00016 of linked axis.

%3:

Expected value [-]

Requested logical axis number P-AXIS-00016 of linked axis.

Error type

1, Error message from NC-program.

 

50463

Platform inclination angle exceeds limit.

 

Description

Exceeding of permissible inclination angle with active kinematic transformation and use of workpiece platform orientation change has occurred.

Further information to kinematic transformation see .

Reaction

Class

4

Movement stop of axes.

Solution

Class

6

Check of programmed position or orientation and correction to smaller values if necessary.

Error type

1, Error message from NC-program.

 

50464

Not all axes known for automatic return to contour after block search.

 

Description

After automatic return to contour after block search the number of channel axis has changed as against the number at program start. This is not allowed.

Reaction

Class

3

Movement stop of axis.

Solution

Class

6

Check NC program for axis exchange command #CALL AX in block search sequence.

Parameter

%1:

State [-]

 

Error type

1, Error message from NC-program.

 

50465

Block forerun parameter : driven way outside the valid range.

 

Description

The parameter “covered distance” with active block search functionality is outside of valid range.

Reaction

Class

3

The value is corrected automatically.

Solution

Class

1

Use correct parameter setting.

Parameter

%1:

Actual value [-]

Command value „covered distance“.

%2:

Corrected value [-]

Corrected value „covered distance“.

%3:

Upper limit value [-]

Upper limit value „covered distance“.

%4:

Lower limit value [-]

Lower limit value „covered distance“.

Error type

1, Error message from NC-program.

 

50466 - 50472

Troubleshooting classes

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

3

 

Solution

Class

8

Restart of NC-control necessary.

50473

Switch on the backwards drive memory without memory impossible.

 

Description

For activation of backward buffer for backward movement memory must be available P-STUP-00033.

Further information to backward movement see

Reaction

Class

1

None.

Solution

Class

1

Set correct buffer memory size in P-STUP-00033.

Error type

-

 

50474

Deviation from contour exceeds limit after manual back to contour during block mode.

 

Description

Repositioning to contour was done manually and the path distance to start position in NC program exceeds permissible limit. The permissible limit can be written by user via HMI or ADS communication objects.

Further information to block search see

Reaction

Class

3

Movement stop.

Solution

Class

6

Check target position with manually repositioning and modify depending on target position in NC program.

Parameter

%1:

Actual value [0.1 µm or 0,0001°]

Current distance before repositioning.

%2:

Limit value [0.1 µm or 0,0001°]

Permissible distance for repositioning.

Error type

1, Error message from NC-program.

 

50475

Block search position contents too many blocks without movement information.

 

Description

In CNC program sequence there are too many non relevant blocks until block search position. Non relevant blocks are CNC program blocks without movement information. In this case the repositioning block in block search is not available in internal buffer memory.

Further information to block search see

Reaction

Class

3

Movement stop.

Solution

Class

7

Check CNC program, remove non relevant blocks if possible or shift block search position.

Parameter

%1:

Actual value [-]

Number of current saved blocks.

Error type

1, Error message from NC-program.

 

50482 - 50486

 

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

6

 

Solution

Class

8

Restart of NC-control necessary.

50487

Maximum permissible axis velocity is limiting.

 

Description

In functionality oscillation axes depending on profile type with relatively high frequency or small period time limiting effects occurs which leads to deviation from the required programmed frequency or period time.

Further information to oscillation axis see.

Reaction

Class

1

Warning, no reaction.

Solution

Class

1

Either reduce programmed frequency and period time respectively or if at all possible increase permissible axis velocity.

Parameter

%1:

Logical axis number [-]

Logical axis number of affected axis P-AXIS-00016.

%2:

Actual value [1µm/sec or 0,001°/sec]

Required desired feed.

%3:

Upper limit value [1µm/sec or 0,001°/sec]

Current permissible axis velocity.

Error type

1, Error message from NC-program.

 

50489 - 50493

 

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

6

 

Solution

Class

8

Restart of NC-control necessary.

50494

Axis acceleration is limiting

 

Description

In functionality oscillating axes depending on profile type with relatively high frequency or small period time limiting effects occurs which leads to deviation from the required programmed frequency or period time.

Further information to oscillation axis see.

Reaction

Class

1

Warning, no reaction.

Solution

Class

1

Either reduce programmed frequency and period time respectively or if at all possible increase permissible axis acceleration.

Parameter

%1:

Logical axis number [-]

Logical axis number of affected axis P-AXIS-00016.

%2:

Actual value [1mm/sec^2 or 1°/sec^2]

Current permissible axis acceleration.

Error type

1, Error message from NC-program.

 

50496 / 50497

 

 

Description

This error message informs about internal states, error solutions and the place of error in the source. Please give the complete error message data to the CNC manufacturer.

Reaction

Class

4

 

Solution

Class

8

Restart of NC-control necessary.

50498

Deceleration path greater than path to go.

 

Description

Path to go P-CHAN-00030 defined in channel parameter list is driven with active functionality edge banding after activation of measurement signal via sensor moving ahead. The path to go available of current active channel block at this moment must be greater than P-CHAN-00030.

Further information to edge banding see.

Reaction

Class

4

Movement stop.

Solution

Class

6

Either reducing of P-CHAN-00030, or increasing of path in programmed channel block to ensure minimum path to go of P-CHAN-00030 after activation of sensor moving ahead.

Parameter

%1:

Actual value [0.1 µm or 0,0001°]

Available path to go in programmed measurement block.

%2:

Expected value [0.1 µm or 0,0001°]

Path to go depending on P-CHAN-00030.

%3:

Actual value [0.1 µm or 0,0001°]

Path distance of measurement actual positions and target positions.

%4:

Actual value [0.1 µm or 0,0001°]

Channel block path.

Error type

1, Error message from NC-program.

 

50499

Spindle speed is 0.

 

Description

With turning functionality feed rate per revolution (G95) and thread cutting (G33) the programmed spindle speed has influence to path feed.

Programmed spindle speed via S word should not be 0 with active turning functions mentioned above..

Reaction

Class

6

Movement stop.

Solution

Class

6

Programming of spindle speed > 0 !

Error type

1, Error message from NC-program.