DynamicVirtualStructInstance Class

Dynamic struct instance

Inheritance Hierarchy

System.Object
  System.Dynamic.DynamicObject
    TwinCAT.TypeSystem.DynamicSymbol
      TwinCAT.TypeSystem.DynamicStructInstance
        TwinCAT.TypeSystem.DynamicVirtualStructInstance
Namespace:  TwinCAT.TypeSystem
Assembly:  TwinCAT.Ads (in TwinCAT.Ads.dll) Version: 4.3.0.0

Syntax

C#

public sealed class DynamicVirtualStructInstance : DynamicStructInstance, 
    IVirtualStructInstance, IStructInstance, ISymbol, IAttributedInstance, IInstance, 
    IBitSize

VB

Public NotInheritable Class DynamicVirtualStructInstance
    Inherits DynamicStructInstance
    Implements IVirtualStructInstance, IStructInstance, ISymbol, IAttributedInstance, 
    IInstance, IBitSize

The DynamicVirtualStructInstance type exposes the following members.

Properties

 

Name

Description

DynamicVirtualStructInstance Class 1:

_InnerSymbol

Inner symbol object wrapped by this DynamicSymbol (Inherited from DynamicSymbol.)

DynamicVirtualStructInstance Class 2:

AccessRights

Gets the access rights. (Inherited from DynamicSymbol.)

DynamicVirtualStructInstance Class 3:

Attributes

Gets the Symbol Attributes (Inherited from DynamicSymbol.)

DynamicVirtualStructInstance Class 4:

BitSize

Gets the size of the IDataType in bits. (Inherited from DynamicSymbol.)

DynamicVirtualStructInstance Class 5:

ByteSize

Gets the (aligned) size of of the Type/Instance in Bytes (Inherited from DynamicSymbol.)

DynamicVirtualStructInstance Class 6:

Category

Gets the category. (Inherited from DynamicSymbol.)

DynamicVirtualStructInstance Class 7:

Comment

Gets the comment of the IInstance (Inherited from DynamicSymbol.)

DynamicVirtualStructInstance Class 8:

Connection

Gets the connection bound to this DynamicSymbol (Inherited from DynamicSymbol.)

DynamicVirtualStructInstance Class 9:

ContextMask

Gets the context mask. (Inherited from DynamicSymbol.)

DynamicVirtualStructInstance Class 10:

DataType

Gets the IDataType of the IInstance. (Inherited from DynamicSymbol.)

DynamicVirtualStructInstance Class 11:

HasRpcMethods

Gets a value indicating whether this instance has RPC methods (Inherited from DynamicStructInstance.)

DynamicVirtualStructInstance Class 12:

HasValue

Gets a value indicating whether this instance has value (only the non VirtualInstances, what means the Symbols with locations). (Inherited from DynamicSymbol.)

DynamicVirtualStructInstance Class 13:

InstanceName

Gets the name of the instance (without periods (.) (Inherited from DynamicSymbol.)

DynamicVirtualStructInstance Class 14:

InstancePath

Gets the relative / absolute access path to the instance (with periods (.)) (Inherited from DynamicSymbol.)

DynamicVirtualStructInstance Class 15:

IsBitType

Gets a value indicating whether this instance is not basing on a full DataType but instead of some sort of bit mapping (Inherited from DynamicSymbol.)

DynamicVirtualStructInstance Class 16:

IsByteAligned

Indicates that the Size of the Object is Byte aligned (BitSize % 8 == 0) (Inherited from DynamicSymbol.)

DynamicVirtualStructInstance Class 17:

IsContainerType

Gets a value indicating whether this Symbol is acontainer type. (Inherited from DynamicSymbol.)

DynamicVirtualStructInstance Class 18:

IsPersistent

Gets a value indicating whether this ISymbol is persistent. (Inherited from DynamicSymbol.)

DynamicVirtualStructInstance Class 19:

IsPointer

Indicates that the IInstance represents a Pointer type (Pointer TO) (Inherited from DynamicSymbol.)

DynamicVirtualStructInstance Class 20:

IsPrimitiveType

Gets a value indicating whether this instance is a primitive type. (Inherited from DynamicSymbol.)

DynamicVirtualStructInstance Class 21:

IsReadOnly

Gets a value indicating whether this ISymbol is read only. (Inherited from DynamicSymbol.)

DynamicVirtualStructInstance Class 22:

IsRecursive

Gets a value indicating whether this instance is recursive. (Inherited from DynamicSymbol.)

DynamicVirtualStructInstance Class 23:

IsReference

Indicates that the IInstance represents a Reference type (REFERENCE TO) (Inherited from DynamicSymbol.)

DynamicVirtualStructInstance Class 24:

IsStatic

Gets a value indicating whether this instance is static. (Inherited from DynamicSymbol.)

DynamicVirtualStructInstance Class 25:

MemberInstances

Gets the member instances of the Struct Instance. (Inherited from DynamicStructInstance.)

DynamicVirtualStructInstance Class 26:

NormalizedName

Gets the normalized instance name (fixed name for dynamic property access that doesn't contain invalid characters), (Inherited from DynamicSymbol.)

DynamicVirtualStructInstance Class 27:

NotificationSettings

Gets the notification settings. (Inherited from DynamicSymbol.)

DynamicVirtualStructInstance Class 28:

Parent

Gets the parent Symbol (Inherited from DynamicSymbol.)

DynamicVirtualStructInstance Class 29:

Size

Gets the size of the IInstance in bytes. (Inherited from DynamicSymbol.)

DynamicVirtualStructInstance Class 30:

SubSymbols

Gets the SubSymbols of the ISymbol (Inherited from DynamicSymbol.)

DynamicVirtualStructInstance Class 31:

TypeName

Gets the name of the DataType that is used for this IInstance. (Inherited from DynamicSymbol.)

Methods

 

Name

Description

DynamicVirtualStructInstance Class 32:

AddMember

Adds an member instance.

DynamicVirtualStructInstance Class 33:

Equals

Equals (Inherited from DynamicSymbol.)

DynamicVirtualStructInstance Class 34:

GetDynamicMemberNames

Returns the enumeration of all dynamic member names. (Inherited from DynamicStructInstance.)

DynamicVirtualStructInstance Class 35:

GetHashCode

Gets the HashCode of the Address (Inherited from DynamicSymbol.)

DynamicVirtualStructInstance Class 36:

GetMetaObject

Provides a DynamicMetaObject that dispatches to the dynamic virtual methods. The object can be encapsulated inside another DynamicMetaObject to provide custom behavior for individual actions. This method supports the Dynamic Language Runtime infrastructure for language implementers and it is not intended to be used directly from your code. (Inherited from DynamicObject.)

DynamicVirtualStructInstance Class 37:

GetType

Gets the Type of the current instance. (Inherited from Object.)

DynamicVirtualStructInstance Class 38:

ReadAnyValue

Reads the value of this Value into a new created instance of the managed type (Inherited from DynamicSymbol.)

DynamicVirtualStructInstance Class 39:

ReadRawValue.

Reads the Symbols raw value (Inherited from DynamicSymbol.)

DynamicVirtualStructInstance Class 40:

ReadRawValue(Int32)

Reads the Symbols raw value (Inherited from DynamicSymbol.)

DynamicVirtualStructInstance Class 41:

ReadValue.

Reads the value of this DynamicSymbol. (Inherited from DynamicSymbol.)

DynamicVirtualStructInstance Class 42:

ReadValue(Int32)

Reads the value of this DynamicSymbol. (Inherited from DynamicSymbol.)

DynamicVirtualStructInstance Class 43:

ToString

Returns a String that represents this instance. (Inherited from DynamicSymbol.)

DynamicVirtualStructInstance Class 44:

TryBinaryOperation

Provides implementation for binary operations. Classes derived from the DynamicObject class can override this method to specify dynamic behavior for operations such as addition and multiplication. (Inherited from DynamicObject.)

DynamicVirtualStructInstance Class 45:

TryConvert

Provides implementation for type conversion operations. Classes derived from the DynamicObject class can override this method to specify dynamic behavior for operations that convert an object from one type to another. (Inherited from DynamicObject.)

DynamicVirtualStructInstance Class 46:

TryCreateInstance

Provides the implementation for operations that initialize a new instance of a dynamic object. This method is not intended for use in C# or Visual Basic. (Inherited from DynamicObject.)

DynamicVirtualStructInstance Class 47:

TryDeleteIndex

Provides the implementation for operations that delete an object by index. This method is not intended for use in C# or Visual Basic. (Inherited from DynamicObject.)

DynamicVirtualStructInstance Class 48:

TryDeleteMember

Provides the implementation for operations that delete an object member. This method is not intended for use in C# or Visual Basic. (Inherited from DynamicObject.)

DynamicVirtualStructInstance Class 49:

TryGetIndex

Provides the implementation for operations that get a value by index. Classes derived from the DynamicObject class can override this method to specify dynamic behavior for indexing operations. (Inherited from DynamicObject.)

DynamicVirtualStructInstance Class 50:

TryGetMember

Provides the implementation for operations that get member values. Classes derived from the DynamicObject class can override this method to specify dynamic behavior for operations such as getting a value for a property. (Inherited from DynamicStructInstance.)

DynamicVirtualStructInstance Class 51:

TryInvoke

Provides the implementation for operations that invoke an object. Classes derived from the DynamicObject class can override this method to specify dynamic behavior for operations such as invoking an object or a delegate. (Inherited from DynamicObject.)

DynamicVirtualStructInstance Class 52:

TryInvokeMember

Provides the implementation for operations that invoke a member. Classes derived from the DynamicObject class can override this method to specify dynamic behavior for operations such as calling a method. (Inherited from DynamicObject.)

DynamicVirtualStructInstance Class 53:

TryReadValue

Reads the Value of the IValueSymbol (Inherited from DynamicSymbol.)

DynamicVirtualStructInstance Class 54:

TrySetIndex

Provides the implementation for operations that set a value by index. Classes derived from the DynamicObject class can override this method to specify dynamic behavior for operations that access objects by a specified index. (Inherited from DynamicObject.)

DynamicVirtualStructInstance Class 55:

TrySetMember

Provides the implementation for operations that set member values. Classes derived from the DynamicObject class can override this method to specify dynamic behavior for operations such as setting a value for a property. (Inherited from DynamicStructInstance.)

DynamicVirtualStructInstance Class 56:

TryUnaryOperation

Provides implementation for unary operations. Classes derived from the DynamicObject class can override this method to specify dynamic behavior for operations such as negation, increment, or decrement. (Inherited from DynamicObject.)

DynamicVirtualStructInstance Class 57:

DynamicVirtualStructInstance Class 58:

TryWriteValue

Writes the specified value to the DynamicSymbol. (Inherited from DynamicSymbol.)

DynamicVirtualStructInstance Class 59:

UpdateAnyValue

Reads the value of this Value into the specified managed value. (Inherited from DynamicSymbol.)

DynamicVirtualStructInstance Class 60:

WriteAnyValue

Writes the value represented by the managed value to this Value (Inherited from DynamicSymbol.)

DynamicVirtualStructInstance Class 61:

WriteRawValue(.Byte.)

Writes the Symbol raw Value (Inherited from DynamicSymbol.)

DynamicVirtualStructInstance Class 62:

WriteRawValue(.Byte., Int32)

Writes the Symbol raw Value (Inherited from DynamicSymbol.)

DynamicVirtualStructInstance Class 63:

WriteValue(Object)

Writes the specified value to the DynamicSymbol. (Inherited from DynamicSymbol.)

DynamicVirtualStructInstance Class 64:

DynamicVirtualStructInstance Class 65:

WriteValue(Object, Int32)

Writes the specified value to the DynamicSymbol. (Inherited from DynamicSymbol.)

Events

 

Name

Description

DynamicVirtualStructInstance Class 66:

RawValueChanged

Occurs when the RawValue of the IValueSymbol has changed. (Inherited from DynamicSymbol.)

DynamicVirtualStructInstance Class 67:

ValueChanged

Occurs when the (Primitive) value of the IValueSymbol has changed. (Inherited from DynamicSymbol.)

Reference

TwinCAT.TypeSystem Namespace