ISymbol Interface

Interface specifying Symbols (

Namespace:  TwinCAT.TypeSystem
Assembly:  TwinCAT.Ads (in TwinCAT.Ads.dll) Version: 4.3.0.0

Syntax

C#

public interface ISymbol : IAttributedInstance, 
    IInstance, IBitSize

VB

Public Interface ISymbol
    Inherits IAttributedInstance, IInstance, IBitSize

The ISymbol type exposes the following members.

Properties

 

Name

Description

ISymbol Interface 1:

Attributes

Gets the Type Attributes. (Inherited from IAttributedInstance.)

ISymbol Interface 2:

BitSize

Gets the size of the IDataType in bits. (Inherited from IBitSize.)

ISymbol Interface 3:

ByteSize

Gets the (aligned) size of of the Type/Instance in Bytes (Inherited from IBitSize.)

ISymbol Interface 4:

Category

Gets the Symbol/Datatype Category

ISymbol Interface 5:

Comment

Gets the comment of the IInstance (Inherited from IInstance.)

ISymbol Interface 6:

DataType

Gets the IDataType of the IInstance. (Inherited from IInstance.)

ISymbol Interface 7:

InstanceName

Gets the name of the instance (without periods (.) (Inherited from IInstance.)

ISymbol Interface 8:

InstancePath

Gets the relative / absolute access path to the instance (with periods (.)) (Inherited from IInstance.)

ISymbol Interface 9:

IsBitType

Gets a value indicating whether this instance is not basing on a full DataType but instead of some sort of bit mapping (Inherited from IBitSize.)

ISymbol Interface 10:

IsByteAligned

Indicates that the Size of the Object is Byte aligned (BitSize % 8 == 0) (Inherited from IBitSize.)

ISymbol Interface 11:

IsContainerType

Gets a value indicating whether this Symbol is a container type.

ISymbol Interface 12:

IsPersistent

Gets a value indicating whether this ISymbol is persistent.

ISymbol Interface 13:

IsPointer

Indicates that the IInstance represents a Pointer type (Pointer TO) (Inherited from IInstance.)

ISymbol Interface 14:

IsPrimitiveType

Gets a value indicating whether this instance is a primitive type.

ISymbol Interface 15:

IsReadOnly

Gets a value indicating whether this ISymbol is read only.

ISymbol Interface 16:

IsRecursive

Gets a value indicating whether this instance is recursive.

ISymbol Interface 17:

IsReference

Indicates that the IInstance represents a Reference type (REFERENCE TO) (Inherited from IInstance.)

ISymbol Interface 18:

IsStatic

Gets a value indicating whether this IInstance is static. (Inherited from IInstance.)

ISymbol Interface 19:

Parent

Gets the parent Symbol

ISymbol Interface 20:

Size

Gets the size of the object in bytes or Bits dependant on IsBitType (Inherited from IBitSize.)

ISymbol Interface 21:

SubSymbols

Gets the SubSymbols of the ISymbol

ISymbol Interface 22:

TypeName

Gets the name of the DataType that is used for this IInstance. (Inherited from IInstance.)

Reference

TwinCAT.TypeSystem Namespace