DynamicSymbol.ReadValue Method

Reads the value of this DynamicSymbol.

Namespace:  TwinCAT.TypeSystem
Assembly:  TwinCAT.Ads (in TwinCAT.Ads.dll) Version: 4.3.0.0

Syntax

C#

public Object ReadValue()

VB

Public Function ReadValue As Object

Return Value

Type: Object
System.Object.

Implements

IValueSymbol.ReadValue.

Remarks

Examples

Dynamic Read access

namespace Sample
{
    using System;
    using System.Diagnostics;
    using System.Threading;
    using TwinCAT;
    using TwinCAT.Ads;
    using TwinCAT.Ads.TypeSystem;
    using TwinCAT.Ads.ValueAccess;
    using TwinCAT.TypeSystem;
    using TwinCAT.TypeSystem.Generic;

    class SymbolBrowserProgramV2DynamicTree
    {

    #region CODE_SAMPLE_SIMPLEDYNAMIC
    /// <summary>
    /// Defines the entry point of the application.
    /// </summary>
    /// <param name="args">The arguments.</param>
    static void Main(string[] args)
    {
        // Get the AdsAddress from command-line arguments
        AmsAddress address = ArgParser.Parse(args);

        using (TcAdsClient client = new TcAdsClient())
        {
        // Connect to the target device
        client.Connect(address);

        // Usage of "dynamic" Type and Symbols (>= .NET4 only)
        SymbolLoaderSettings settings = new SymbolLoaderSettings(SymbolsLoadMode.DynamicTree);
        IAdsSymbolLoader dynLoader = (IAdsSymbolLoader)SymbolLoaderFactory.Create(client, settings);

        #endregion

        // Set the Default setting for Notifications
        dynLoader.DefaultNotificationSettings = new NotificationSettings(AdsTransMode.OnChange, 200, 2000);

        // Get the Symbols (Dynamic Symbols)
        dynamic dynamicSymbols = ((IDynamicSymbolLoader)dynLoader).SymbolsDynamic;

        dynamic adsPort = dynamicSymbols.TwinCAT_SystemInfoVarList._AppInfo.AdsPort;

        #region CODE_SAMPLE_SIMPLEDYNAMIC

        // Access Main Symbol with Dynamic Language Runtime support (DLR)
        // Dynamically created property "Main"
        //dynamic symMain = dynamicSymbols.Main;

        // Main is an 'VirtualSymbol' / Organizational unit that doesn't have a value
        // Calling ReadValue is not allowed
        //bool test = symMain.HasValue;
        //dynamic invalid = symMain.ReadValue();

        //Reading TaskInfo Value
        //With calling ReadValue() a 'snapshot' of the Symbols Instance is taken
        dynamic vTaskInfoArray = dynamicSymbols.TwinCAT_SystemInfoVarList._TaskInfo.ReadValue(); 

        // Getting the Snapshot time in UTC format
        DateTime timeStamp1 = vTaskInfoArray.UtcTimeStamp;

        // Getting TaskInfo Symbol for Task 1
        dynamic symTaskInfo1 = dynamicSymbols.TwinCAT_SystemInfoVarList._TaskInfo[1];

        // Getting CycleCount Symbol
        dynamic symCycleCount = symTaskInfo1.CycleCount;


        // Take Snapshot value of the ApplicationInfo struct
        dynamic vAppInfo = dynamicSymbols.TwinCAT_SystemInfoVarList._AppInfo.ReadValue();
        // Get the UTC Timestamp of the snapshot

        DateTime timeStamp2 = vAppInfo.UtcTimeStamp;

        // Access the ProjectName of the ApplicationInfo Snapshot (type-safe!)
        string projectNameValue = vAppInfo.ProjectName;

        // Reading the CycleCount Value
        uint cycleCountValue = symTaskInfo1.CycleCount.ReadValue();     // Taking a Value Snapshot
        #endregion

        // Registering for dynamic "ValueChanged" events for the Values
        // Using Default Notification settings           
        symCycleCount.ValueChanged += new EventHandler<ValueChangedArgs>(cycleCount_ValueChanged);

        // Override default notification settings
        symTaskInfo1.NotificationSettings = new NotificationSettings(AdsTransMode.Cyclic,500,0);

        // Register for ValueChanged event.
        symTaskInfo1.ValueChanged += new EventHandler<ValueChangedArgs>(taskInfo1Value_ValueChanged); // Struct Type

        Thread.Sleep(10000); // Sleep main thread for 10 Seconds
        }
        Console.WriteLine("CycleCount Changed events received: {0}",_cycleCountEvents);
        Console.WriteLine("taskInfo1 Changed events received: {0}", _taskInfo1Events);

        Console.WriteLine("");
        Console.WriteLine("Press [Enter] for leave:");
        Console.ReadLine();
    }

    static object _notificationSynchronizer = new object();
    static int _cycleCountEvents = 0;

    /// <summary>
    /// Handler function for the CycleCount ValueChanged event.
    /// </summary>
    /// <param name="sender">The sender.</param>
    /// <param name="e">The e.</param>
    static void cycleCount_ValueChanged(object sender, ValueChangedArgs e)
    {
        lock(_notificationSynchronizer)
        {
        Interlocked.Increment(ref _cycleCountEvents);
        // val is a type safe value of int!
        dynamic val = e.Value;
        uint intVal = val;

        DateTime changedTime = e.UtcRtime.ToLocalTime(); // Convert UTC to local time
        Console.WriteLine("CycleCount changed to: {0}, TimeStamp: {1}", intVal, changedTime.ToString("HH:mm:ss:fff"));
        }
    }

    static int _taskInfo1Events = 0;

    /// <summary>
    /// Handler function for the TaskInfo ValueChanged event.
    /// </summary>
    /// <param name="sender">The sender.</param>
    /// <param name="e">The e.</param>
    static void taskInfo1Value_ValueChanged(object sender, ValueChangedArgs e)
    {
        lock (_notificationSynchronizer)
        {
        Interlocked.Increment(ref _taskInfo1Events);
        dynamic val = e.Value;
        DateTime changedTime = e.UtcRtime.ToLocalTime(); // Convert to local time

        // Val is a during Runtime created struct type and contains
        // the same Properties as related PLC object.
        int cycleTime = val.CycleTime;
        Console.WriteLine("TaskInfo1Value changed TimeStamp: {0}", changedTime.ToString("HH:mm:ss:fff"));
        }
    }
    }
}

Reference

DynamicSymbol Class

ReadValue Overload

TwinCAT.TypeSystem Namespace