DynamicReferenceInstance Class

Dynamic Reference Instance

Inheritance Hierarchy

System.Object
  System.Dynamic.DynamicObject
    TwinCAT.TypeSystem.DynamicSymbol
      TwinCAT.TypeSystem.DynamicReferenceInstance
Namespace:  TwinCAT.TypeSystem
Assembly:  TwinCAT.Ads (in TwinCAT.Ads.dll) Version: 4.3.0.0

Syntax

C#

public sealed class DynamicReferenceInstance : DynamicSymbol, 
    IReferenceInstance, ISymbol, IAttributedInstance, IInstance, IBitSize

VB

Public NotInheritable Class DynamicReferenceInstance
    Inherits DynamicSymbol
    Implements IReferenceInstance, ISymbol, IAttributedInstance, IInstance, 
    IBitSize

The DynamicReferenceInstance type exposes the following members.

Properties

 

Name

Description

DynamicReferenceInstance Class 1:

_InnerSymbol

Inner symbol object wrapped by this DynamicSymbol (Inherited from DynamicSymbol.)

DynamicReferenceInstance Class 2:

AccessRights

Gets the access rights. (Inherited from DynamicSymbol.)

DynamicReferenceInstance Class 3:

Attributes

Gets the Symbol Attributes (Inherited from DynamicSymbol.)

DynamicReferenceInstance Class 4:

BitSize

Gets the size of the IDataType in bits. (Inherited from DynamicSymbol.)

DynamicReferenceInstance Class 5:

ByteSize

Gets the (aligned) size of of the Type/Instance in Bytes (Inherited from DynamicSymbol.)

DynamicReferenceInstance Class 6:

Category

Gets the category. (Inherited from DynamicSymbol.)

DynamicReferenceInstance Class 7:

Comment

Gets the comment of the IInstance (Inherited from DynamicSymbol.)

DynamicReferenceInstance Class 8:

Connection

Gets the connection bound to this DynamicSymbol (Inherited from DynamicSymbol.)

DynamicReferenceInstance Class 9:

ContextMask

Gets the context mask. (Inherited from DynamicSymbol.)

DynamicReferenceInstance Class 10:

DataType

Gets the IDataType of the IInstance. (Inherited from DynamicSymbol.)

DynamicReferenceInstance Class 11:

HasValue

Gets a value indicating whether this instance has value (only the non VirtualInstances, what means the Symbols with locations). (Inherited from DynamicSymbol.)

DynamicReferenceInstance Class 12:

InstanceName

Gets the name of the instance (without periods (.) (Inherited from DynamicSymbol.)

DynamicReferenceInstance Class 13:

InstancePath

Gets the relative / absolute access path to the instance (with periods (.)) (Inherited from DynamicSymbol.)

DynamicReferenceInstance Class 14:

IsBitType

Gets a value indicating whether this instance is not basing on a full DataType but instead of some sort of bit mapping (Inherited from DynamicSymbol.)

DynamicReferenceInstance Class 15:

IsByteAligned

Indicates that the Size of the Object is Byte aligned (BitSize % 8 == 0) (Inherited from DynamicSymbol.)

DynamicReferenceInstance Class 16:

IsContainerType

Gets a value indicating whether this Symbol is acontainer type. (Inherited from DynamicSymbol.)

DynamicReferenceInstance Class 17:

IsPersistent

Gets a value indicating whether this ISymbol is persistent. (Inherited from DynamicSymbol.)

DynamicReferenceInstance Class 18:

IsPointer

Indicates that the IInstance represents a Pointer type (Pointer TO) (Inherited from DynamicSymbol.)

DynamicReferenceInstance Class 19:

IsPrimitiveType

Gets a value indicating whether this instance is a primitive type. (Inherited from DynamicSymbol.)

DynamicReferenceInstance Class 20:

IsReadOnly

Gets a value indicating whether this ISymbol is read only. (Inherited from DynamicSymbol.)

DynamicReferenceInstance Class 21:

IsRecursive

Gets a value indicating whether this instance is recursive. (Inherited from DynamicSymbol.)

DynamicReferenceInstance Class 22:

IsReference

Indicates that the IInstance represents a Reference type (REFERENCE TO) (Inherited from DynamicSymbol.)

DynamicReferenceInstance Class 23:

IsStatic

Gets a value indicating whether this instance is static. (Inherited from DynamicSymbol.)

DynamicReferenceInstance Class 24:

NormalizedName

Gets the normalized instance name (fixed name for dynamic property access that doesn't contain invalid characters), (Inherited from DynamicSymbol.)

DynamicReferenceInstance Class 25:

NotificationSettings

Gets the notification settings. (Inherited from DynamicSymbol.)

DynamicReferenceInstance Class 26:

Parent

Gets the parent Symbol (Inherited from DynamicSymbol.)

DynamicReferenceInstance Class 27:

Size

Gets the size of the IInstance in bytes. (Inherited from DynamicSymbol.)

DynamicReferenceInstance Class 28:

SubSymbols

Gets the SubSymbols of the ISymbol (Inherited from DynamicSymbol.)

DynamicReferenceInstance Class 29:

TypeName

Gets the name of the DataType that is used for this IInstance. (Inherited from DynamicSymbol.)

Methods

 

Name

Description

DynamicReferenceInstance Class 30:

Equals

Equals (Inherited from DynamicSymbol.)

DynamicReferenceInstance Class 31:

GetDynamicMemberNames

Returns the enumeration of all dynamic member names. (Overrides DynamicSymbol.GetDynamicMemberNames..)

DynamicReferenceInstance Class 32:

GetHashCode

Gets the HashCode of the Address (Inherited from DynamicSymbol.)

DynamicReferenceInstance Class 33:

GetMetaObject

Provides a DynamicMetaObject that dispatches to the dynamic virtual methods. The object can be encapsulated inside another DynamicMetaObject to provide custom behavior for individual actions. This method supports the Dynamic Language Runtime infrastructure for language implementers and it is not intended to be used directly from your code. (Inherited from DynamicObject.)

DynamicReferenceInstance Class 34:

GetType

Gets the Type of the current instance. (Inherited from Object.)

DynamicReferenceInstance Class 35:

ReadAnyValue

Reads the value of this Value into a new created instance of the managed type (Inherited from DynamicSymbol.)

DynamicReferenceInstance Class 36:

ReadRawValue.

Reads the Symbols raw value (Inherited from DynamicSymbol.)

DynamicReferenceInstance Class 37:

ReadRawValue(Int32)

Reads the Symbols raw value (Inherited from DynamicSymbol.)

DynamicReferenceInstance Class 38:

ReadValue.

Reads the value of this DynamicSymbol. (Inherited from DynamicSymbol.)

DynamicReferenceInstance Class 39:

ReadValue(Int32)

Reads the value of this DynamicSymbol. (Inherited from DynamicSymbol.)

DynamicReferenceInstance Class 40:

ToString

Returns a String that represents this instance. (Inherited from DynamicSymbol.)

DynamicReferenceInstance Class 41:

TryBinaryOperation

Provides implementation for binary operations. Classes derived from the DynamicObject class can override this method to specify dynamic behavior for operations such as addition and multiplication. (Inherited from DynamicObject.)

DynamicReferenceInstance Class 42:

TryConvert

Provides implementation for type conversion operations. Classes derived from the DynamicObject class can override this method to specify dynamic behavior for operations that convert an object from one type to another. (Inherited from DynamicObject.)

DynamicReferenceInstance Class 43:

TryCreateInstance

Provides the implementation for operations that initialize a new instance of a dynamic object. This method is not intended for use in C# or Visual Basic. (Inherited from DynamicObject.)

DynamicReferenceInstance Class 44:

TryDeleteIndex

Provides the implementation for operations that delete an object by index. This method is not intended for use in C# or Visual Basic. (Inherited from DynamicObject.)

DynamicReferenceInstance Class 45:

TryDeleteMember

Provides the implementation for operations that delete an object member. This method is not intended for use in C# or Visual Basic. (Inherited from DynamicObject.)

DynamicReferenceInstance Class 46:

TryGetIndex

Provides the implementation for operations that get a value by index. Classes derived from the DynamicObject class can override this method to specify dynamic behavior for indexing operations. (Overrides DynamicObject.TryGetIndex(GetIndexBinder, .Object., Object.).)

DynamicReferenceInstance Class 47:

TryGetMember

Provides the implementation for operations that get member values. Classes derived from the DynamicObject class can override this method to specify dynamic behavior for operations such as getting a value for a property. (Overrides DynamicSymbol.TryGetMember(GetMemberBinder, Object.).)

DynamicReferenceInstance Class 48:

TryInvoke

Provides the implementation for operations that invoke an object. Classes derived from the DynamicObject class can override this method to specify dynamic behavior for operations such as invoking an object or a delegate. (Inherited from DynamicObject.)

DynamicReferenceInstance Class 49:

TryInvokeMember

Provides the implementation for operations that invoke a member. Classes derived from the DynamicObject class can override this method to specify dynamic behavior for operations such as calling a method. (Inherited from DynamicObject.)

DynamicReferenceInstance Class 50:

TryReadValue

Reads the Value of the IValueSymbol (Inherited from DynamicSymbol.)

DynamicReferenceInstance Class 51:

TrySetIndex

Provides the implementation for operations that set a value by index. Classes derived from the DynamicObject class can override this method to specify dynamic behavior for operations that access objects by a specified index. (Overrides DynamicObject.TrySetIndex(SetIndexBinder, .Object., Object).)

DynamicReferenceInstance Class 52:

TrySetMember

Provides the implementation for operations that set member values. Classes derived from the DynamicObject class can override this method to specify dynamic behavior for operations such as setting a value for a property. (Overrides DynamicObject.TrySetMember(SetMemberBinder, Object).)

DynamicReferenceInstance Class 53:

TryUnaryOperation

Provides implementation for unary operations. Classes derived from the DynamicObject class can override this method to specify dynamic behavior for operations such as negation, increment, or decrement. (Inherited from DynamicObject.)

DynamicReferenceInstance Class 54:

DynamicReferenceInstance Class 55:

TryWriteValue

Writes the specified value to the DynamicSymbol. (Inherited from DynamicSymbol.)

DynamicReferenceInstance Class 56:

UpdateAnyValue

Reads the value of this Value into the specified managed value. (Inherited from DynamicSymbol.)

DynamicReferenceInstance Class 57:

WriteAnyValue

Writes the value represented by the managed value to this Value (Inherited from DynamicSymbol.)

DynamicReferenceInstance Class 58:

WriteRawValue(.Byte.)

Writes the Symbol raw Value (Inherited from DynamicSymbol.)

DynamicReferenceInstance Class 59:

WriteRawValue(.Byte., Int32)

Writes the Symbol raw Value (Inherited from DynamicSymbol.)

DynamicReferenceInstance Class 60:

WriteValue(Object)

Writes the specified value to the DynamicSymbol. (Inherited from DynamicSymbol.)

DynamicReferenceInstance Class 61:

DynamicReferenceInstance Class 62:

WriteValue(Object, Int32)

Writes the specified value to the DynamicSymbol. (Inherited from DynamicSymbol.)

Events

 

Name

Description

DynamicReferenceInstance Class 63:

RawValueChanged

Occurs when the RawValue of the IValueSymbol has changed. (Inherited from DynamicSymbol.)

DynamicReferenceInstance Class 64:

ValueChanged

Occurs when the (Primitive) value of the IValueSymbol has changed. (Inherited from DynamicSymbol.)

Reference

TwinCAT.TypeSystem Namespace