SumHandleWrite Class
Write any (primitive) values by Handle SumCommandBase.
Inheritance Hierarchy
System.Object
SumCommandBase
SumWrite
TwinCAT.Ads.SumCommand.SumHandleWrite
Namespace: TwinCAT.Ads.SumCommand
Assembly: TwinCAT.Ads (in TwinCAT.Ads.dll)
Version: 6.0.328+39e3229
Syntax
C#
public class SumHandleWrite : SumWriteThe SumHandleWrite type exposes the following members.
Methods
|
|
Name |
Description |
|---|---|---|
|
|
Determines whether the specified object is equal to the current object. (Inherited from Object.) | |
|
|
Allows an object to try to free resources and perform other cleanup operations before it is reclaimed by garbage collection. (Inherited from Object.) | |
|
|
Serves as the default hash function. (Inherited from Object.) | |
|
|
Gets the Type of the current instance. (Inherited from Object.) | |
|
|
Creates a shallow copy of the current Object. (Inherited from Object.) | |
|
|
Returns a string that represents the current object. (Inherited from Object.) | |
|
|
Tries to write the values. | |
|
|
Writes the values to the Symbols. | |
|
|
Write the values asynchronously. |
Remarks
This is an ADS Sum Command to access values by handle information. It is always used in combination with and . By design (and in contrast to the symbolic access in SumRead, SumSymbolWrite) this access method can act only with ADS ANY Type (Primitive) values (disadvantage). The Advantage is, that no symbolic information must be loaded before accessing the values, see samples:
Examples
Usage of Sum commands with handles (CreateHandles, Read, Write, ReleaseHandles)
/// <summary>
/// Defines the entry point of the application.
/// </summary>
/// <param name="args">The arguments.</param>
static async void Main(string[] args)
{
Console.WriteLine("");
Console.WriteLine("Press [Enter] for start:");
Console.ReadLine();
// Parse the command-line arguments
AmsAddress address = ArgParser.Parse(args);
CancellationTokenSource cancelSource = new CancellationTokenSource();
CancellationToken cancel = cancelSource.Token;
using (AdsClient client = new AdsClient())
{
// Connect the AdsClient to the device target.
client.Connect(address);
string[] instancePathList = {
"GVL.bVar",
"GVL.iCount",
"TwinCAT_SystemInfoVarList._AppInfo.ProjectName"
};
SumCreateHandles createHandlesCommand = new SumCreateHandles(client,instancePathList);
var resultCreateHandles = await createHandlesCommand.CreateHandlesAsync(cancel);
if (resultCreateHandles.Succeeded)
{
uint[] handles = resultCreateHandles.Handles;
Type[] valueTypes = new Type[]
{
typeof(bool),
typeof(short),
typeof(string)
};
SumHandleRead readCommand = new SumHandleRead(client, handles, valueTypes);
var resultRead = await readCommand.ReadAsync(cancel);
if (resultRead.Succeeded)
{
object[] readValues = resultRead.Values;
for (int i = 0; i < instancePathList.Length; i++)
{
Console.WriteLine("Symbol: {0} (Value: {1}, Type: {2})", instancePathList[i], readValues[i].ToString(), valueTypes[i].Name);
}
// Sum Command Write
SumHandleWrite writeCommand = new SumHandleWrite(client, handles, valueTypes);
object[] writeValues = new object[] { true, (short)42, "MyNewProjectName" };
await writeCommand.WriteAsync(writeValues,cancel);
}
SumReleaseHandles releaseCommand = new SumReleaseHandles(client, handles);
await releaseCommand.ReleaseHandlesAsync(cancel);
}
}
Console.WriteLine("");
Console.WriteLine("Press [Enter] for leave:");
Console.ReadLine();
}Reference
TwinCAT.Ads.SumCommand Namespace
TwinCAT.Ads.SumCommand.SumCreateHandles
TwinCAT.Ads.SumCommand.SumReleaseHandles
TwinCAT.Ads.SumCommand.ISumCommand
TwinCAT.Ads.SumCommand.SumReleaseHandles