SumCreateHandles Class

SumCommand for getting variable handles by a set of InstancePaths and using the Handles cache.

Inheritance Hierarchy

System.Object
  SumCommandBase
    TwinCAT.Ads.SumCommand.SumCreateHandles

Namespace: TwinCAT.Ads.SumCommand
Assembly: TwinCAT.Ads (in TwinCAT.Ads.dll) Version: 7.0.0+e56d35ccc4675faac24789a4aab60071fc61d470

Syntax

C#

public class SumCreateHandles : SumCommandBase

The SumCreateHandles type exposes the following members.

Constructors

 

Name

Description

SumCreateHandles Class 1:

SumCreateHandles(IAdsConnection, IList<String>)

Initializes a new instance of the SumCreateHandles class.

SumCreateHandles Class 2:

SumCreateHandles(IAdsConnection, IList<String>, SumCommandErrorStrategy, SumFallbackMode)

Initializes a new instance of the SumCreateHandles class.

Methods

 

Name

Description

SumCreateHandles Class 3:

CreateHandles

Creates the ADS handles.

SumCreateHandles Class 4:

CreateHandlesAsync

Create handles asynchronously.

SumCreateHandles Class 5:

Equals

Determines whether the specified object is equal to the current object.
(Inherited from Object)

SumCreateHandles Class 6:

Finalize

Allows an object to try to free resources and perform other cleanup operations before it is reclaimed by garbage collection.
(Inherited from Object)

SumCreateHandles Class 7:

GetHashCode

Serves as the default hash function.
(Inherited from Object)

SumCreateHandles Class 8:

GetType

Gets the Type of the current instance.
(Inherited from Object)

SumCreateHandles Class 9:

MemberwiseClone

Creates a shallow copy of the current Object.
(Inherited from Object)

SumCreateHandles Class 10:

ToString

Returns a string that represents the current object.
(Inherited from Object)

Remarks

The SumCreateHandles SumCommand creates the variable Handles not via the IHandleCache internally used by the AdsClient. Therefore the overloads of the IConnection should be used.

Example

Usage of Sum commands with handles (CreateHandles, Read, Write, ReleaseHandles)

/// <summary>
/// Defines the entry point of the application.
/// </summary>
/// <param name="args">The arguments.</param>
static async void Main(string[] args)
{
    Console.WriteLine("");
    Console.WriteLine("Press [Enter] for start:");
    Console.ReadLine();

    // Parse the command-line arguments
    AmsAddress address = ArgParser.Parse(args);

    CancellationTokenSource cancelSource = new CancellationTokenSource();
    CancellationToken cancel = cancelSource.Token;

    using (AdsClient client = new AdsClient())
    {
    // Connect the AdsClient to the device target.
    client.Connect(address);

    string[] instancePathList = {
        "GVL.bVar",
        "GVL.iCount",
        "TwinCAT_SystemInfoVarList._AppInfo.ProjectName"
    };
    SumCreateHandles createHandlesCommand = new SumCreateHandles(client,instancePathList);

    var resultCreateHandles = await createHandlesCommand.CreateHandlesAsync(cancel);

    if (resultCreateHandles.Succeeded)
    {
        uint[] handles = resultCreateHandles.Handles;
        Type[] valueTypes = new Type[]
        {
        typeof(bool),
        typeof(short),
        typeof(string)
        };
        SumHandleReadAnyType readCommand = new SumHandleReadAnyType(client, handles, valueTypes, SumFallbackMode.All);
        var resultRead = await readCommand.ReadAsync(cancel);

        if (resultRead.Succeeded)
        {
        object[] readValues = resultRead.Values;

        for (int i = 0; i < instancePathList.Length; i++)
        {
            Console.WriteLine("Symbol: {0} (Value: {1}, Type: {2})", instancePathList[i], readValues[i].ToString(), valueTypes[i].Name);
        }

        // Sum Command Write
        SumHandleWriteAnyType writeCommand = new SumHandleWriteAnyType(client, handles, valueTypes);
        object[] writeValues = new object[] { true, (short)42, "MyNewProjectName" };

        await writeCommand.WriteAsync(writeValues,cancel);
        }

        SumReleaseHandles releaseCommand = new SumReleaseHandles(client, handles);
        await releaseCommand.ReleaseHandlesAsync(cancel);
    }
    }

    Console.WriteLine("");
    Console.WriteLine("Press [Enter] for leave:");
    Console.ReadLine();
}

See Also

Reference

TwinCAT.Ads.SumCommand Namespace ISumCommand SumReleaseHandles SumCreateHandlesBase SumHandleReadAnyType SumHandleWriteAnyType