Process data for KL3362
In the Process data tab, you can specify which data are displayed in the process image of the KL3362 oscilloscope terminal.

Output process image
- Data word 0
For trigger unit 1, select which trigger parameter you wish to specify with data word 0 (DataOUT0, channel 1) of the KL3362 (see Output process data in detail).
- Data word 1
For trigger unit 2, select which trigger parameter you wish to specify with data word 1 (DataOUT1, channel 1) of the KL3362 (see Output process data in detail).
- Data word 2
For trigger unit 3, select which trigger parameter you wish to specify with data word 2 (DataOUT0, channel 2) of the KL3362 (see Output process data in detail).
- Data word 3
For trigger unit 4, select which trigger parameter you wish to specify with data word 3 (DataOUT1, channel 2) of the KL3362 (see Output process data in detail).
Input process image
- Data word 0
Here you can specify which input value is transferred with data word 0 (DataIN0, channel 1) from the KL3362 to the controller (see Input process data in detail).
- Data word 1
Here you can specify which input value is transferred with data word 1 (DataIN1, channel 1) from the KL3362 to the controller (see Input process data in detail).
- Data word 2
Here you can specify which input value is transferred with data word 2 (DataIN0, channel 2) from the KL3362 to the controller (see Input process data in detail).
- Data word 3
Here you can specify which input value is transferred with data word 3 (DataIN1, channel 2) from the KL3362 to the controller (see Input process data in detail).