DS402 Process data

Table of contents

Sync Manager (SM)

Sync Manager (SM) The extent of the process data that is made available can be changed through the "Process data" tab (see Fig. Process Data tab SM2, EL72x1-0010 (default)).

DS402 Process data 1:
Process Data tab SM2, EL72x1-0010 (default)
DS402 Process data 2:
Process Data tab SM3, EL72x1-0010 (default)

PDO Assignment

SM2, PDO assignment 0x1C12

Index

Size (byte.bit)

Name

PDO Content
Index - name, size (byte.bit)

0x1600 (default)

2.0

DS402 Controlword

0x6040 - Controlword (2.0)

0x1601 (default)

4.0

DS402 Target velocity

0x60FF -Target velocity (4.0)

0x1602

2.0

DS402 Target torque

0x6071 - Target torque (2.0)

0x1603

2.0

DS402 Commutation angle

0x60EA - Commutation angle (2.0)

0x1604

2.0

DS402 Torque limitation

0x6072 - Max. torque (2.0)

0x1605

2.0

DS402 Torque offset

0x2001:11 - Torque offset (2.0)

0x1606

4.0

DS402 Target position

0x607A - Target position (4.0)

0x1607

2.0

DS402 FB Touch probe function

0x60B8 - Touch probe function (2.0)

Bit 0
Bit 1
Bit 2
Bit 4
Bit 5

Bit 8
Bit 9
Bit 10
Bit 12
Bit 13

TP1 Enable
TP1 Continous
TP1 Trigger mode
TP1 Enable pos. edge
TP1 Enable neg. edge

TP2 Enable
TP2 Continous
TP2 Trigger mode
TP2 Enable pos. edge
TP2 Enable neg. edge

0x1608

1.0

DS402 Modes of operation

0x6060 - Modes of operation (1.0)

SM3, PDO Assignment 0x1C13

Index

Size (byte.bit)

Name

PDO Content
Index - name, size (byte.bit)

0x1A00 (default)

2.0

DS402 Statusword

0x6041 - Statusword (2.0)

0x1A01 (default)

4.0

DS402 Position actual value

0x6064 - Position actual value (4.0)

0x1A02

4.0

DS402 Velocity actual value

0x606C - Velocity actual value (4.0)

0x1A03

2.0

DS402 Torque actual value

0x6077 - Torque actual value (2.0)

0x1A04

4.0

DS402 Following error actual value

0x60F4 - Following error actual value (4.0)

0x1A05

2.0

DS402 Touch probe status

 

0x60B9 - Touch probe status (2.0)

Bit 0
Bit 1
Bit 2
Bit 7

Bit 8
Bit 9
Bit 10
Index 6001:10

TP1 Enable
TP1 Pos. value stored
TP1 Neg. value stored
TP1 Input

TP2 Enable
TP2 Pos. value stored
TP2 Neg. value stored
TP2 Input

0x1A06

4.0

DS402 Touch probe 1 positive edge

0x60BA - Touch probe 1 positive edge (4.0)

0x1A07

4.0

DS402 Touch probe 1 negative edge

0x60BB - Touch probe 1 negative edge (4.0)

0x1A08

4.0

DS402 Touch probe 2 positive edge

0x60BC - Touch probe 2 positive edge (4.0)

0x1A09

4.0

DS402 Touch probe 2 negative edge

0x60BD - Touch probe 2 negative edge (4.0)

0x1A0A

2.0

DS402 TxPDO Data Invalid

0x603E:02 - TxPDO Data invalid_Position actual value (0.1)

0x1A0B

2.0

DS402 Info data 1

0x2008:01 - Info data 1 (2.0)

0x1A0C

2.0

DS402 Info data 2

0x2008:02 - Info data 2 (2.0)

0x1A0E

1.0

DS402 Modes of operation display

0x6061:00 - Modes of operation display (1.0)

Predefined PDO Assignment

The "Predefined PDO Assignment" enables a simplified selection of the process data. The desired function is selected on the lower part of the "Process Data" tab. As a result, all necessary PDOs are automatically activated and the unnecessary PDOs are deactivated.

Four PDO assignments are available:

Name

SM2, PDO assignment

SM3, PDO assignment

Cyclic synchronous velocity mode
(CSV)

0x1600 (DS402 Controlword)

0x1601 (DS402 Target velocity)

0x1A00 (DS402 Statusword)

0x1A01 (DS402 Position actual value)

Cyclic synchronous torque mode
(CST)

0x1600 (DS402 Controlword)

0x1602 (DS402 Target torque)

0x1A00 (DS402 Statusword)

0x1A01 (DS402 Position actual value)

0x1A03 (DS402 Torque actual value)

Cyclic synchronous torque mode with commutation angle
(CSTCA)

0x1600 (DS402 Controlword)

0x1602 (DS402 Target torque)

0x1603 (DS402 Commutation angle)

0x1A00 (DS402 Statusword)

Cyclic synchronous position mode
(CSP)

0x1600 (DS402 Controlword)

0x1606 (DS402 Target position)

0x1A00 (DS402 Statusword)

0x1A01 (DS402 Position actual value)

0x1A04 (DS402 Following error actual value)

DS402 Process data 3:
Process data tab - Predefined PDO Assignment, EL72x1-0011