Standard objects
The standard objects have the same meaning for all EtherCAT slaves.
Index 1000 Device type
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1000:0 |
Device type |
Device type of the EtherCAT slave: The Lo-Word contains the CoE profile used (5002). |
UINT32 |
RO |
0x0000138A (5002dec) |
Index 1008 Device name
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1008:0 |
Device name |
Device name of the EtherCAT slave |
STRING |
RO |
EL6740-0010-0000 |
Index 1009 Hardware version
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1009:0 |
Hardware version |
Hardware version of the EtherCAT slave |
STRING |
RO |
00 |
Index 100A Software version
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
100A:0 |
Software version |
Firmware version of the EtherCAT slave |
STRING |
RO |
01 |
Index 1010 Store Interbus Configuration (from FW 02)
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1010:0 |
Store Parameters |
Saving the current Interbus configuration |
UINT8 |
RW |
0x01 (1dec) |
|
1010:01 |
Codeword |
The current Interbus configuration from object 0xF800:02 is stored in the EL6740-0010 when 0x65766173 ("evas") is written to index 1010:01. To this end the terminal must be in OP or SAFE-OP state. Once these settings have been saved, other Interbus configurations are rejected with abort code 0x0026 during transition to SAFE-OP. |
UINT32 |
RW |
0x00000000 (0dec) |
Index 1011 Restore Interbus Configuration (ab FW 02)
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1011:0 |
Restore Parameters |
Resetting the stored Interbus configuration |
UINT8 |
RW |
0x01 (1dec) |
|
1011:01 |
Codeword |
The Interbus configuration stored in the EL6740-0010 is deleted when 0x64616F6C ("daol") is written to index 0x1011:01. To this end the terminal must be in OP or SAFE-TOP state. |
UINT32 |
RW |
0x00000000 (0dec) |
Index 1018 Identity
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1018:0 |
Identity |
Information for identifying the slave |
UINT8 |
RO |
0x04 (4dez) |
|
1018:01 |
Vendor ID |
Vendor ID of the EtherCAT slave |
UINT32 |
RO |
0x00000002 (2dez) |
|
1018:02 |
Product code |
Product code of the EtherCAT slave |
UINT32 |
RO |
0x1A543052 (441725010dez) |
|
1018:03 |
Revision |
Revision number of the EtherCAT slave; the low word (bit 0-15) indicates the special terminal number, the high word (bit 16-31) refers to the device description |
UINT32 |
RO |
0x0000000A (10dez) |
|
1018:04 |
Serial number |
Serial number of the EtherCAT slave; the low byte (bit 0-7) of the low word contains the year of production, the high byte (bit 8-15) of the low word contains the week of production, the high word (bit 16-31) is 0 |
UINT32 |
RO |
0x00000000 (0dez) |
Index 1400 RxPDO parameter
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1400:0 |
RxPDO parameter |
Max. Subindex |
UINT8 |
RO P |
0x07 (7dez) |
|
1400:07 |
Status |
Status Rx PDO
|
BOOL |
RO P |
TRUE |
Index 1600 RxPDO Mapping Box 001
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1600:0 |
RxPDO Mapping Box 001 |
Max. Subindex |
UINT8 |
RW |
0x03 (3dec) |
|
1600:01 |
Output Mapping Area 001 |
PDO mapping range 001** |
UINT32 |
RW |
0x7000:01, nnn** |
|
... |
... |
... |
... |
. |
. |
|
1600:03 |
Output Mapping Area 003 |
PDO mapping range 003** |
UINT32 |
RW |
0x0000:00, nnn** |
**dynamically generated object, size depends on process variable
Index 1601 PDO control
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1601:0 |
PDO control |
Max. Subindex |
UINT8 |
RW |
0x01 (1dec) |
|
1601:01 |
|
Dummy |
UINT32 |
RW |
0x0000:00, 16 |
Index 1800 TxPDO parameter
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1800:0 |
TxPDO parameter |
Max. Subindex |
UINT8 |
RO P |
0x07 (7dec) |
|
1800:07 |
Status |
Status Tx PDO
|
BOOL |
RO P |
TRUE |
Index 1A00 TxPDO Mapping Box 001
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1A00:0 |
TxPDO Mapping Box 001 |
Max. Subindex |
UINT8 |
RW |
0x03 (3dec) |
|
1A00:01 |
Input Mapping Area 001 |
PDO mapping area 001** |
UINT32 |
RW |
0x6000:01, nnn** |
|
... |
... |
... |
... |
. |
. |
|
1A00:03 |
Intput Mapping Area 003 |
PDO mapping area 003** |
UINT32 |
RW |
0x0000:00, nnn** |
**dynamically generated object, size depends on process variable
Index 1A01 PDO status
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1A01:0 |
PDO status |
Max. Subindex |
UINT8 |
RW |
0x04 (4dec) |
|
1A01:01 |
[Alignment] |
Alignment dummy |
UINT32 |
RW |
0x0000:00, 13 |
|
1A01:02 |
Rx PDO status |
Status Rx PDO |
UINT32 |
RW | |
|
1A01:03 |
Tx PDO status |
Status Tx PDO |
UINT32 |
RW | |
|
1A01:04 |
[Alignment] |
Alignment-Dummy |
UINT32 |
RW |
0x0000:00, 1 |
Index 1C00 Sync manager type
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1C00:0 |
Sync manager type |
Using the sync managers |
UINT8 |
RO |
0x02 (2dec) |
|
1C00:01 |
SubIndex 001 |
Sync-Manager Type Channel 1: Mailbox Write |
UINT8 |
RO |
0x01 (1dez) |
|
1C00:02 |
SubIndex 002 |
Sync-Manager Type Channel 2: Mailbox Read |
UINT8 |
RO |
0x02 (2dec) |
Index 1C12 RxPDO assign
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1C12:0 |
RxPDO assign |
PDO Assign Outputs |
UINT8 |
RW |
0x02 (2dec |
|
1C12:01 |
SubIndex 001 |
1. allocated RxPDO (contains the index of the associated RxPDO mapping object) |
UINT16 |
RW |
0x1601 (5633dez) |
|
1C12:02 |
SubIndex 002 |
2. allocated RxPDO (contains the index of the associated RxPDO mapping object) |
UINT16 |
RW |
0x1600 (5632dez) |
Index 1C13 TxPDO assign
|
Index (hex) |
Name |
Meaning |
Data type |
Flags |
Default |
|---|---|---|---|---|---|
|
1C13:0 |
TxPDO assign |
PDO Assign Inputs |
UINT8 |
RW |
0x02 (2dez |
|
1C13:01 |
SubIndex 001 |
1. allocated TxPDO (contains the index of the associated TxPDO mapping object) |
UINT16 |
RW |
0x1A01 (6657dez) |
|
1C13:02 |
SubIndex 002 |
2. allocated TxPDO (contains the index of the associated TxPDO mapping object) |
UINT16 |
RW |
0x1A00 (6656dez) |