Counter value reset

A recurring reset of the counter value in the process data “Counter value” (0x60n0:11) to “0” can be done in the following ways:

The settings are made in the configuration data, so it is not necessary to reactivate the device after a reset.

It is not possible to activate the “Enable C reset” (Index 0x80n0:01) and “Enable extern reset” (Index 0x80n0:02) functions at the same time.

Counter value reset via the zero pulse C input (Enable C reset)

The counter value can be set to the value specified in index 0x80n1:1BReset counter value” for every full revolution of the encoder via the zero pulse C.

Counter value reset via the “Latch extern” input (Enable extern reset)

The counter value can be set to “0” via the “Latch extern” input.

There is no status message via the process data.