Control cabinet installation
Notice | |
Extreme environmental conditions Extreme environmental conditions can cause damage to the device.
|
Notice | |
Incorrect installation Incorrect installation in a control cabinet prevents air circulation in the device and causes impaired functioning.
|
The device is designed for installation in the front of a control cabinet in machine and system engineering. The environmental conditions specified for operation must be observed.
Using different mounting plates, you can align the cable entry based on the application requirements.
Figure 8 shows the two available mounting plates: the standard mounting plate 1 and the optional mounting plate 2. In both cases, the plate is screwed to the right-hand side panel of the industrial PC with four Torx TX10 screws at a tightening torque of approx. 0.5 Nm. You can turn both mounting plates before fastening them such that the PC can be mounted in the desired orientation for the cable entry in the control cabinet (see Chapter 4.2.1 Mounting options).
The basic version of the industrial PC is supplied with the standard mounting plate 1 already mounted as shown in Fig. 8. The scope of delivery does not include any further mounting plates. You can choose the following ordering options:
Order identifier | Version |
---|---|
C9900-M668 | Mounting plate on the side wall, instead of the standard mounting plate |
C9900-M693 | Mounting plate for lateral mounting of the C604x, single part, not mounted |