S-0-0011 Class 1 diagnostic (C1D)

The parameter contains error groups that trigger a “drive shut down” error.

Attributes

Name

Value

Data type

Binary

Data length

16

Decimal point

0

Min value

-

Max value

-

Default

-

Unit

-

Changeable in EtherCAT state

No

Cyclic transfer

AT

Device parameter

No

Related to interface revision

No

If an error is diagnosed in the drive, this results in an error reaction and the error bit is set, as described below. In addition, error bit 13 of S-0-0135 is set to “1” and is only reset to “0” by the drive when the drive has executed command S-0-0099 and no error remains.
To precisely identify the error, read the error memory.

Bit pattern:

Bit

Meaning

0

Overload shut down
Overload shutdown

0 = no error
1 = error

1

Amplifier overtemperature shut down
Amplifier overtemperature shutdown

0 = no error
1 = error

2

Motor overtemperature shut down
Motor overtemperature shutdown

0 = no error
1 = error

3

Cooling error shutdown
Cooling error shutdown

0 = no error
1 = error

4

Control voltage error
Control voltage error

0 = no error
1 = error

5

Feedback error
Feedback error

0 = no error
1 = error

6

Commutation error
Commutation error

0 = no error
1 = error

7

Overcurrent error
Overcurrent error

0 = no error
1 = error

8

Overvoltage error
Overvoltage error

0 = no error
1 = error

9

Undervoltage error
Undervoltage error

0 = no error
1 = error

10

Power supply phase error
Power supply phase error

0 = no error
1 = error

11

Excessive position deviation
Excessive position deviation

0 = no error
1 = error

12

Communication error bit
Communication error

0 = no error
1 = error

13

Overtravel limit exceeded
The overtravel limit has been exceeded (shutdown)

0 = no error
1 = error

14

Reserved

15

Manufacturer specific error
Manufacturer specific error

0 = no error
1 = error

S-0-0011 Class 1 diagnostic (C1D) 1:

IDN P-0-0350 - Error reaction control word

With this IDN you can parameterize a general reaction to an error and/or influence the behavior of the two axes in the case of a 2-channel AX5000.

S-0-0011 Class 1 diagnostic (C1D) 2:

IDNs involved

S-0-0099, S-0-0135, P-0-0350