SWCNFG2
ASCII - Command  | SWCNFG2  | 
  | 
  | |
Syntax Transmit  | SWCNFG2 [Data]  | 
  | ||
Syntax Receive  | SWCNFG2 <Data>  | Available in  | 
  | |
Type  | Variable rw  | MMI  | Yes  | |
ASCII Format  | Unsigned16  | CANBus Object Number  | 3601 (hex)  | |
DIM  | -  | PROFIBUS PNU  | 1857 (dec) IND = 0000xxxx (bin)  | |
Range  | 0 .. 65535  | DPR  | 257 (dec)  | |
Default  | 0  | 
  | ||
Opmode  | All  | Data Type Bus/DPR  | Unsigned16  | |
Drive State  | Disabled + Reset (Coldstart)  | Weightning  | 
  | |
Start Firmware  | 1.71  | 
  | ||
Configuration  | Yes  | Revision  | 1.6  | |
Function Group  | Position Controller  | EEPROM  | Yes  | |
Short Description  | Configuration of Position Registers 0 and 5  | |||
Description
The configuration variable SWCNFG2 can be used to define the function of position registers 0 and 5. The SWCNFG2 variable can be considered as a bit-variable. The individual bits are interpreted as follows:
- Bit 0 =0 Position/cam register SWE0 is not active
 - =1 Position/cam register SWE0 is active
 - Bit 1 =0 Signal on going above the position (PFB > SWE0) Signal if SWE0 < PFB < SWE0N and cam function is activated
 - =1 Signal on going below the position (PFB < SWE0)
Signal if SWE0 > PFB > SWE0N and cam function is activated - Bit 2 Reserve
 - Bit 3 =1 Cam function for SWE0 / SWE0N
 - Bit 4 =0 Position/cam register SWE5 is not active
 - =1 Position/cam register SWE5 is active
 - Bit 5 =0 Signal on going above the position (PFB > SWE5) Signal if SWE5 < PFB < SWE5N and cam function is activated
 - =1 Signal on going below the position (PFB < SWE5) Signal if SWE5 > PFB > SWE5N and cam function is activated
 - Bit 6 Reserve
 - Bit 7 =1 Cam function for SWE5 / SWE5N
 
see also description of SWCNFG