OS5

ASCII - Command

OS5

 

 

Syntax Transmit

OS5 [Data]

 

Syntax Receive

OS5 <Data>

Available in

 

Type

Variable rw

MMI

No

ASCII Format

Integer8

CANBus Object Number

36CB (hex)

DIM

-

PROFIBUS PNU

1659 (dec) IND = 0001xxxx (bin)

Range

0, 1

DPR

459 (dec)

Default

-

 

Opmode

All

Data Type Bus/DPR

Integer8

Drive State

-

Weightning

 

Start Firmware

5.41

 

Configuration

No

Revision

1.9

Function Group

Digital I/O

EEPROM

No

Short Description

Set/Reset of "Posreg5" of the I/O Option Card

Description

The I/O option card has 5 output pins which are normally used to signal on position registers SWE0-4.

OS5 sets the digital output "PosReg5" (terminal 10 of X11B) of the I/O option card.

Set SWCNFG2 Bit 0 to "0" to disable the appropriate register (SWE0) to reassign the output for use in general purpose mode.

This command allows using the output for general purposes through standard communication channels or through motion tasking.